How to replace a gas valve - Rooftop Gas Pack
How to replace a gas valve. Rooftop gas pack HVAC gas valve replacement.
Переглядів: 413

Відео

How to restring an electric heater.
Переглядів 1,2 тис.6 місяців тому
Electric heater repair, auxiliary heat repair, emergency heat repair, replacing elements in heater kit.
How to plug a tire
Переглядів 1032 роки тому
Using a "tubeless tire repair kit" to fix a puncture in a service truck tire.
How to clean a ductless high wall
Переглядів 2052 роки тому
How to clean a ductless high wall unit using the following: Phillips head screw driver or drill bit Coiljet pressure washer Minisplit bib kit XL Evap Green Hot water Flash light Step Stool
Dryer Vent Cleaning
Переглядів 2122 роки тому
A quick cleaning of a dryer vent that runs through the slab of the building and is constructed mainly of PVC.
Bad TXV in Heat Pump Condenser
Переглядів 13 тис.2 роки тому
How to diagnose, remove & replace a bad thermostatic expansion valve in a heat pump condenser.
How to build a duct shroud on site
Переглядів 6 тис.2 роки тому
Building a simple cover for package unit ductwork using sheet metal and basic hand tools.
Troubleshooting low voltage shorts
Переглядів 19 тис.2 роки тому
On this video we are looking into a method of troubleshooting low voltage shorts. This equipment is a residential 208-230 volt single phase gas/ac package unit with an ecobee 5 thermostat.
A blower motor replacement
Переглядів 2812 роки тому
Replacing a blower motor in a Lennox air handler. An OEM part was used. Includes a step by step process and capacitor Check.
Maintenance Visit Walkthrough
Переглядів 2082 роки тому
What we do on maintenance visits. Air filters provided - filter changer reminders sent to customers - electrical component diagnostics - refrigerant system diagnostics - condenser coil cleaning - evaporative coil cleaning - condensate drain cleaning - assessment of HVAC system condition - assessment of any accessories that make for a better customer experience and less HVAC system downtime.
How to Check Charge on Bryant or Carrier Communicating Equipment
Переглядів 2,5 тис.2 роки тому
Checking refrigerant charge on Bryant Evolution, Carrier Infinity and other ICP Multistage Products.
5 Stage Condesnser Install HD 1080p
Переглядів 2782 роки тому
In depth look of the condenser portion of a heat pump system replacement. Heat Pump Replacement, Service Disconnect Replacement, Electrical Whip Replacement, Brazing, Evacuation/Vacuum. Material Used: Bryant Evolution 17 SEER 5 Stage 5 Ton Heat Pump System Ultravation 5" Filter Box & Filter 3" Heat Pump Risers 7/8 Corrosion "Grenade" Rector Seal RSH 50 Surge Protector Equipment & Tools Used Fie...
Scroll Compressor Replacement
Переглядів 3 тис.3 роки тому
We came across a dead compressor during a scheduled maintenance call. Compressor ohms out within specifications but trips the breaker when the contractor is engaged.
A walkthrough for RLS press fittings in HVACR
Переглядів 23 тис.3 роки тому
A walkthrough for RLS press fittings in HVACR
Complete ductless heat pump installation
Переглядів 6563 роки тому
Complete ductless heat pump installation
Leak detection method for HVAC copper line sets
Переглядів 5 тис.3 роки тому
Leak detection method for HVAC copper line sets
Replacing Condenser Fan Motors
Переглядів 4383 роки тому
Replacing Condenser Fan Motors
Random Day of Maintenance Calls
Переглядів 4503 роки тому
Random Day of Maintenance Calls
Bryant 32 SEER Ductless Install
Переглядів 1,7 тис.3 роки тому
Bryant 32 SEER Ductless Install
Replacing Compressors
Переглядів 5373 роки тому
Replacing Compressors
1.5 Ton Ductless Install
Переглядів 4113 роки тому
1.5 Ton Ductless Install
18 SEER Installation - Heat Pump
Переглядів 1,5 тис.3 роки тому
18 SEER Installation - Heat Pump
Brazing with a nitrogen flow
Переглядів 3,9 тис.3 роки тому
Brazing with a nitrogen flow
Package unit install - Heat Pumps
Переглядів 2,9 тис.3 роки тому
Package unit install - Heat Pumps
Defrost Board Replacement
Переглядів 3,2 тис.3 роки тому
Defrost Board Replacement
Leak detection and repair
Переглядів 6483 роки тому
Leak detection and repair
Refrigerant level check in heat mode
Переглядів 41 тис.3 роки тому
Refrigerant level check in heat mode
Troubleshooting thermostats
Переглядів 3983 роки тому
Troubleshooting thermostats
Troubleshooting contactors
Переглядів 7 тис.3 роки тому
Troubleshooting contactors
Troubleshooting transformers
Переглядів 43 тис.3 роки тому
Troubleshooting transformers

КОМЕНТАРІ

  • @smacleod69
    @smacleod69 22 дні тому

    Duct board needs to be outlawed!

  • @AdamBerwanger
    @AdamBerwanger 24 дні тому

    So what I’ve learned you have to put in the correct line set diameter length verify evaporator coil model number is a match then do your stabilization. After that, it will give you a target sub cooling, then you can go to check out and run the system on speed five to check your refrigerant charge. Once you’ve done the stabilization once after that, you only have to just go to the checkout mode.

  • @kingtucky4300
    @kingtucky4300 Місяць тому

    Very easy n to point. I understand a lot better. Sometimes things seem overwhelming n complicated, but it just takes someone who been there to make it make since. Thanks

  • @hazendismukesjr.8319
    @hazendismukesjr.8319 Місяць тому

    The risers are a good idea

  • @hazendismukesjr.8319
    @hazendismukesjr.8319 Місяць тому

    Great filosopy no down time do it right the first time

  • @hazendismukesjr.8319
    @hazendismukesjr.8319 Місяць тому

    I'm in central Alabama

  • @hazendismukesjr.8319
    @hazendismukesjr.8319 Місяць тому

    You are not supposed to use reducers on gas line only bell reducers. Where I live.

  • @marcellabenjamin6449
    @marcellabenjamin6449 Місяць тому

    Oh shit! I took it out the box! I was wondering why it was hard to come off. One filter wasted…🤦🏽‍♀️🥴🤣

  • @CabECalloway
    @CabECalloway Місяць тому

    Thank you!

  • @thomasmcdonald5758
    @thomasmcdonald5758 Місяць тому

    The filter Dryer should always be installed inside of the house close to the evaporator coil to prevent corrosion from the outside elements.

    • @AIRMANHVAC
      @AIRMANHVAC Місяць тому

      @@thomasmcdonald5758 never seen a filter drier fail from the “outside elements”. The reason the filter drier’s preferred location is near the evap coil is to offer better protection for the metering device. Installing it outside near the condenser is a completely acceptable practice. We’ll just have to disagree on that issue.

    • @thomasmcdonald5758
      @thomasmcdonald5758 Місяць тому

      @@AIRMANHVAC The filter dryer’s manufactured 15-20 year ago had thicker metal and like everything else was made much better, the newer filter dryers have much thinner metal and when they are under snow ice and freezing temperatures the elements cause much faster deterioration.

  • @stephenacman3244
    @stephenacman3244 Місяць тому

    ME TO BROTHER, I ONLY CARRY 5 AMP FUSES AS WELL!! 24 yr exp tech from Va. Love your videos, nice work.

  • @user-pf9ig8wc1c
    @user-pf9ig8wc1c 2 місяці тому

    What type of filter dryer do you use with those ends on it?

  • @ocastego8645
    @ocastego8645 2 місяці тому

    I should use RLS or acr?

  • @elvinrodrguez5
    @elvinrodrguez5 2 місяці тому

    Can you explain Why Fuse Pops when I connect the Y’s to the furnace control board? Like I can’t power Outdoor unit with 24v because it pops

    • @AIRMANHVAC
      @AIRMANHVAC 2 місяці тому

      There must be a short of some kind in your wiring or the contactor in the condensing unit.

  • @camilo8cheryl
    @camilo8cheryl 3 місяці тому

    The minute he dropped that filter dryer on the ground and not cleaning it prior to attaching it to the unit😂

    • @AIRMANHVAC
      @AIRMANHVAC 3 місяці тому

      😂 3 years later and the system still doesn’t care

  • @karenwilliams476
    @karenwilliams476 3 місяці тому

    Mine is like this one but, it feels like it's stuck and not coming out.

  • @mylesm7947
    @mylesm7947 3 місяці тому

    That drier connection is pipe dia. Not connector dia. ???

  • @williamfabiano543
    @williamfabiano543 3 місяці тому

    Great information and no B.S.

  • @DeeZTv12
    @DeeZTv12 3 місяці тому

    Always add two 2 and a half inches

  • @valeriesmith1064
    @valeriesmith1064 3 місяці тому

    My door has screws on each side that holds the door on . But on the door it says 20x22x1/4 and i can’t find a filter anywhere that size . So I bought a 20x22x1 and you can’t get them out you literally have to tear it up getting it out. What should I do . I just bought the house last year .

  • @Gary-ts6dh
    @Gary-ts6dh 3 місяці тому

    1:47 - I hope you didn't ask to borrow that man's phone after knowing what he just did in the background of your video! I used the RLS (Rapid Locking System) tools and fittings for the first time yesterday on a walk-in cooler and had leaks on every fitting. Note to self: the center of the jaws _do not_ go over the rib where the o-ring is in the fitting! I needed to _Read the Fabulous Manual_ before starting.

  • @dustinhopper1184
    @dustinhopper1184 4 місяці тому

    My fuse will last a month or two. So its hard to find the short and is intermittently happening.

  • @shantall_sharee
    @shantall_sharee 4 місяці тому

    Thanks I’ve been placing mine wrong for a year 😂

  • @adminaspx
    @adminaspx 4 місяці тому

    How yo carry 200 boxes of filter to the roof is my question?

  • @sandrawedding
    @sandrawedding 4 місяці тому

    My filter has wire on both sides.

    • @sandrawedding
      @sandrawedding 4 місяці тому

      Serial number on unit is FJ4DNX. It never came with a filter. So I had to go purchase one from Walmart.

    • @AIRMANHVAC
      @AIRMANHVAC 4 місяці тому

      There should be an air flow direction indication on the filter.

    • @sandrawedding
      @sandrawedding 4 місяці тому

      @@AIRMANHVAC would that be the arrow?

    • @AIRMANHVAC
      @AIRMANHVAC 4 місяці тому

      @@sandrawedding yes

    • @sandrawedding
      @sandrawedding 4 місяці тому

      @@AIRMANHVAC thank you! It doesn’t specify if the arrow goes up or down. But the arrow is opposite of the writing. 🤷🏼‍♀️

  • @skyeomalley3259
    @skyeomalley3259 4 місяці тому

    I searched for twenty minutes for a simple answer, finally found it here. Thank you.

  • @Pittie_Huff
    @Pittie_Huff 4 місяці тому

    Ser this was so helpful. One question, we recently Bought a townhome and there is not only an air filter seen here, but I found a carrier washable filter sitting on the ground. Do I use both of these filters?

    • @AIRMANHVAC
      @AIRMANHVAC 4 місяці тому

      Our recommendation is to filter air at one location.

  • @manuelherreros4609
    @manuelherreros4609 4 місяці тому

    Hello can you press txv valves?

  • @CremeBrulee543
    @CremeBrulee543 4 місяці тому

    Thank you! Going to flip mine now lol

  • @alvarolucio8264
    @alvarolucio8264 4 місяці тому

    Boa Noite sou daqui do Brasil a parte do aquecimento corre risco pra fazer brasagem na tubulação com o tubo perto de gás?

  • @living9377
    @living9377 4 місяці тому

    Great explanation. Thank you for sharing!

  • @fermin0614
    @fermin0614 5 місяців тому

    What a good explanation thanks 🙏

  • @autumnhickerson2149
    @autumnhickerson2149 5 місяців тому

    lets talk about the neighbors ac leaning lol. nice work man great video

  • @kaylalee20201
    @kaylalee20201 5 місяців тому

    I got the same drill and bit great for doing service work

  • @pitbulllife4198
    @pitbulllife4198 5 місяців тому

    P have you ever used duct a later you may want to invest

  • @pitbulllife4198
    @pitbulllife4198 5 місяців тому

    No way in hell my house would look like that with all that flex hanging like that that's way too much flex y'all should have cut that s*** off and made it look a lot better cuz that s*** looks like s*** and then people should be pissed I guess the inspector don't give a s***what you install because that s*** right there that s*** right there and get a motherfuking fired that s*** looks unprofessional as f***

  • @pitbulllife4198
    @pitbulllife4198 5 місяців тому

    Let me ask everybody something if there's metal out there like that was and you just put off the takeoffs why wouldn't you finish the job with metal that don't make sense to me 2 90 on each side with a work with no problem I don't understand why you put flex in there instead of metal don't make sense I'm from Florida and that's how I would have done it I would have put 290 on each takeoff into the other pipe that's called professional and then build a dog house over it

  • @pitbulllife4198
    @pitbulllife4198 5 місяців тому

    The case why wouldn't you sell them a surge protector

  • @pitbulllife4198
    @pitbulllife4198 5 місяців тому

    I've never seen anybody put locks and drives that's using the Pittsburgh and putting lots and drives we call what you just did is a dog house 🏡 did you put a piece on😅

  • @pitbulllife4198
    @pitbulllife4198 5 місяців тому

    I'll send it I don't understand it why is he doing all that and he can make 90s and I don't get it three-piece 90s I mean what the f*** is going on in their boy somebody's going to be pissed

  • @pitbulllife4198
    @pitbulllife4198 5 місяців тому

    Damn dude could have saved them thousands of dollars all you had to do was do it down zone system in that b**** I don't understand why you running that much f****** duck man that's crazy

  • @pitbulllife4198
    @pitbulllife4198 5 місяців тому

    You see that s*** that angle he's talking about covering up there should be no angle there if he knew how to do his ductwork right there would not be no angle there he didn't I don't understand what the hell he's doing and that's just shity work laziness or not knowing what to do

  • @pitbulllife4198
    @pitbulllife4198 5 місяців тому

    I think I'd be pretty pissed off at a job like this I'm not going to lie to you and they're using metal strap to hang the unit are you shiting me now why aren't you using all thread and unistrut and then the pan then the pan under that and then you're putting the duck backwards that s*** don't make no sense that first box you just cut if that's the supply why is it going backwards I mean I think I would be a little pissed off just to be honest with you because that's not right

  • @oklahomalane
    @oklahomalane 5 місяців тому

    Finally a video where the filter is actually horizontal! My filter has wire in both sides (Filtrete 20x25x1, Merv 13, blue on the sides). “Air coming from the bottom and going up” did it for me. Arrow is pointing up. Thanks!

    • @AIRMANHVAC
      @AIRMANHVAC 5 місяців тому

      You’re welcome!

  • @user-jc5mt3ev4i
    @user-jc5mt3ev4i 6 місяців тому

    Thank youuu!! Finally someone that has clear direction! 😃

  • @erockscott1184
    @erockscott1184 6 місяців тому

    How come the three pole contactor doesn't have a 24 volt connector on the middle pin???

    • @AIRMANHVAC
      @AIRMANHVAC 6 місяців тому

      No need for a middle pin….when 24 volts is applied between the two “coil” pins, the contactor closes.

    • @erockscott1184
      @erockscott1184 6 місяців тому

      I'm just wondering what L3 is used for. I got this three pole contactor according to my manufacturer specs and part number to find they only have a 2 pole in the unit. So I'm gonna use the three pole since I bought it. It doesn't mount right but oh well I'll put self drilling screws where I need them I guess.

    • @AIRMANHVAC
      @AIRMANHVAC 6 місяців тому

      @@erockscott1184 just don’t use a pole/L3. 3 pole contactors are used in equipment that uses 3 phase power. Typically you see single and double pole contactors in equipment using single phase power.

    • @erockscott1184
      @erockscott1184 6 місяців тому

      Ok...I was thinking though...lol..that if one pole went bad i could switch to the other and "shift" them down one....lol

  • @seadeas
    @seadeas 6 місяців тому

    Good job talking people through this, explaining and showing.., Thanks 🙏

  • @anthonys6187
    @anthonys6187 6 місяців тому

    So do you just use a 5 amp popper fuse as well for trouble shooting or do you carry both 3 and 5 for testing purposes?

    • @AIRMANHVAC
      @AIRMANHVAC 6 місяців тому

      I haven’t had good results using a popper….transformers getting burnt up. I keep a big box of 5 amps only. No issues using just 5’s.

  • @KJ6EAD
    @KJ6EAD 6 місяців тому

    Other than overstretching the nichrome coils a bit, not bad. It looks like you could leave the coils short initially, make the two end terminations, then stretch the coils in situ to fit the space. Alternatively, use a piece of copper or aluminum wire to simulate the serpentine path of the coils, then straighten and measure to get a more accurate length. Do you find those adjustable thermal switches to be as reliable as the fixed ones?

    • @AIRMANHVAC
      @AIRMANHVAC 6 місяців тому

      I haven't had any callbacks or problems with the adjustable limit switches. Definitely go that route to save space on the service trucks.

  • @b320i3
    @b320i3 6 місяців тому

    On the filter is the dirty side on the bottom or top

    • @AIRMANHVAC
      @AIRMANHVAC 6 місяців тому

      For this application the filter will collect “dirt” on the bottom

    • @b320i3
      @b320i3 6 місяців тому

      @@AIRMANHVAC Thank you. I have a new Carrier unit since May. There is a metal filter that was installed. Is it ok to use paper filters from Home Depot or should I get a metal one.

    • @AIRMANHVAC
      @AIRMANHVAC 6 місяців тому

      @@b320i3 I use a merv 11 or 13 depending on what’s cheaper at the time