Joondalup Electrical Services
Australia
Приєднався 27 гру 2019
I supply, repair and install Off Grid (Stand Alone Power Supply) and suburban solar power systems. Take a look at what I do as I share some of my jobs with you on my You Tube channel. I am a licensed Electrician and registered Electrical Contractor of 25 years specialising in solar and battery in Perth Western Australia.
Fixing an Alpha ESS battery system that has not worked since it was installed 2 years ago in Perth!
Many of my jobs involve fixing up other peoples mistakes and sloppy workmanship. Sometimes its just that they rushed the commissioning process and failed to realise the system wasnt working correctly. A lot of the time they simply dont give a s&@t wether its working or not! This one was the latter, the installer told the client he doesnt have on him the correct meter for three phase so the battery will just charge from the grid WTF! The client then spent the next two years trying to get the retailer to come back and fix it. Eventually he resigned to the fact he is going to have to pay to get it working which is where I come in. The retailer in question has typically had a good reputation but it sounds like that is no longer the case. So when buying solar or batteries be sure to “Empower” yourself and follow the steps in the video link below to avoid getting burnt.
ua-cam.com/video/Rk67AFwiLOA/v-deo.htmlsi=r-f1oTdo-vZOee3V
#perth #solar#fault #repairs #fail #joondalup #electrical #services
#battery #inverter
ua-cam.com/video/Rk67AFwiLOA/v-deo.htmlsi=r-f1oTdo-vZOee3V
#perth #solar#fault #repairs #fail #joondalup #electrical #services
#battery #inverter
Переглядів: 483
Відео
Sigenergy hybrid battery, installation and review by a solar professional! Whats it really like?
Переглядів 4,3 тис.Місяць тому
This is my first Sigenergy hybrid battery system installation, in this video I run you through the installation process, and give my honest opinion of this latest technology from Sigenergy. #sigenergy #sigenpro #battery #inverter #solar #review #price #perth #repairs #fault #installer #how #sigenstore
What did I do wrong? Why did it catch fire……
Переглядів 9 тис.2 місяці тому
I finally got around to doing another one of these videos displaying what can happen when you use poor quality or incorrectly, rated equipment on your solar and battery system. It took me a long time to get this one together. It’s hard trying to find enough time to make these videos, so I hope you enjoy it as much as I did. Growatt SPF5000 review. ua-cam.com/video/_2vGNLfnVcY/v-deo.htmlsi=NjHCz...
How to install solar panels on a tin/metal roof.
Переглядів 8262 місяці тому
This video I share some tips on how to install solar panels on a metal roof using the Clenergy rail system. What to watch out for, what to be aware of and some tools that come in handy. #solar #diy #battery #tips #offgrid #solarpanelinstallation #perth #power #fault #repair
Fixing a water leak on a tiled roof under solar panels. Perth solar power repairs.
Переглядів 6942 місяці тому
This video gives a good example of how not to install tile interface brackets for solar panels. I got called to this job for a water leak which was located under the solar panels on this house in Perth. In order to repair the water leak, I had to remove the solar panel and replace some cracked clay roof tiles, then reinstall the tile hook / interface bracket correctly. #perth #solar #repairs #...
Finding that your solar panels were not connected ten years after they were installed!
Переглядів 7272 місяці тому
I was recently called to do an assessment on a solar system in Perth that was installed 10 years ago, the owners had a feeling that the system wasn’t working correctly and was faulty. They had contacted the retailer after the solar system was installed with concerns but their enquiries were ignored! The original retailer was Infinite Energy, a company that no longer exists which is an all too f...
PowerPlus Energy battery upgrade on Selectronic off grid power system.
Переглядів 7082 місяці тому
This video is a quick example of how easy it is to add extra power plus energy batteries to an existing system. These batteries are 24 V 3.3 kWh units. This system is a replacement of an old Outback Power off grid system that was made redundant. It also had some old lead acid batteries. #powerplusenergy #battery #offgrid #solar #perth #lithiumbattery #selectronic #fronius #offgridsolar #upgrade...
Off Grid Powerwall upgrade in remote Western Australia. Adding a third battery to one of my sites.
Переглядів 6652 місяці тому
Tesla Powerwall 2 will no longer be available soon, not the end of the world for a grid connected client but if your Off Grid and planning on expanding its a major inconvenience. This is one of five Tesla Off Grid sites I have that works flawlessly since day 1. The owners have decided to add another battery while they still can. Tesla do not support this configuration amymore which is a shame. ...
Why cheap solar will cost you more in the long term. Cheapest solar quote is not always best option!
Переглядів 2832 місяці тому
Why cheap solar will cost you more in the long term. Cheapest solar quote is not always best option!
I think I have found the best three phase home battery solution. Sigenergy.
Переглядів 3,7 тис.3 місяці тому
I think I have found the best three phase home battery solution. Sigenergy.
How to avoid getting ripped off when buying a home solar battery system, learn from my experience!
Переглядів 1 тис.3 місяці тому
How to avoid getting ripped off when buying a home solar battery system, learn from my experience!
How to connect your SMA inverter to your home Wi-Fi network the correct way.
Переглядів 5154 місяці тому
How to connect your SMA inverter to your home Wi-Fi network the correct way.
Tired of your energy retailer (Synergy) and want to go off grid in suburbia?
Переглядів 15 тис.4 місяці тому
Tired of your energy retailer (Synergy) and want to go off grid in suburbia?
Fault finding a Victron Off Grid solar power system that keeps shutting down with Pylontech battery.
Переглядів 1,1 тис.4 місяці тому
Fault finding a Victron Off Grid solar power system that keeps shutting down with Pylontech battery.
How to connect your SMA inverter to your WiFi network using WPS method. The easy way.
Переглядів 8004 місяці тому
How to connect your SMA inverter to your WiFi network using WPS method. The easy way.
Earth insulation fault, trying to locate an earth fault on a solar system. Fronius 475 code.
Переглядів 9484 місяці тому
Earth insulation fault, trying to locate an earth fault on a solar system. Fronius 475 code.
Growatt SPF5000ES Off Grid inverter/charger review, is cheaper better? Perth solar system repairs.
Переглядів 2,6 тис.4 місяці тому
Growatt SPF5000ES Off Grid inverter/charger review, is cheaper better? Perth solar system repairs.
Oversizing your inverter with SolarEdge technology, how to get the most from a single phase inverter
Переглядів 5904 місяці тому
Oversizing your inverter with SolarEdge technology, how to get the most from a single phase inverter
Solar power monitoring Solar Analytics, fixing the plants in my fleet that aren’t working anymore
Переглядів 7595 місяців тому
Solar power monitoring Solar Analytics, fixing the plants in my fleet that aren’t working anymore
Solar Power is a waste of money for many consumers. I explain how to avoid wasting your money!
Переглядів 2,7 тис.5 місяців тому
Solar Power is a waste of money for many consumers. I explain how to avoid wasting your money!
How to remove solar panels where the clamps are all seized the easy way.
Переглядів 2 тис.5 місяців тому
How to remove solar panels where the clamps are all seized the easy way.
How to replace an integrated SolarEdge optimizer solar panel and setup in the monitoring platform.
Переглядів 1 тис.6 місяців тому
How to replace an integrated SolarEdge optimizer solar panel and setup in the monitoring platform.
Stuck on a two story roof in the rain. Solar guy life 😅
Переглядів 2276 місяців тому
Stuck on a two story roof in the rain. Solar guy life 😅
Victron three phase Off Grid build with Multiplus 2 and Ruixu battery
Переглядів 7 тис.6 місяців тому
Victron three phase Off Grid build with Multiplus 2 and Ruixu battery
Perth solar and battery repairs, maintenance and replacement of inverters, panels, off grid in WA
Переглядів 3607 місяців тому
Perth solar and battery repairs, maintenance and replacement of inverters, panels, off grid in WA
How to check if a solar panel is working 🙃😅 DC short circuit on an LG solar panel.
Переглядів 7587 місяців тому
How to check if a solar panel is working 🙃😅 DC short circuit on an LG solar panel.
Ants ruining inverters, how not to mount solar panels. Perth solar inverter repairs Off Grid.
Переглядів 2 тис.7 місяців тому
Ants ruining inverters, how not to mount solar panels. Perth solar inverter repairs Off Grid.
Twelve Able generators later they finally have a quality Off Grid power supply!
Переглядів 1 тис.8 місяців тому
Twelve Able generators later they finally have a quality Off Grid power supply!
When solar panels, melt the glass, Crap Solar!
Переглядів 5399 місяців тому
When solar panels, melt the glass, Crap Solar!
ABB Aurora and Power One E031 fault, what does it mean and can it be fixed.
Переглядів 1,5 тис.10 місяців тому
ABB Aurora and Power One E031 fault, what does it mean and can it be fixed.
Very honest review. Just what we want to hear. A BIG THANKS.
Thanks mate 👍🏻
Nice review. The EV DC charge module sits in/on the battery/inverter stack - which is not much good for EV charging unless the stack is located near where the car is parked, e.g. in a garage/car port.
Yes valid point 👍🏻
This is just plainly not true... Who the hell told you that?
It’s crazy what people believe
You did a good job
I bet the customer is wrapped 🤙🇦🇺
They were very relieved to finally have it working 🙌🏻😊
Nice work Jase, bet they're happy to know someone has the knowledge to get everything working properly, Happy New Year mate !! 🤠😎
Cheers mate, Happy New Year to you too 😊👍🏻
Great video. Interesting points about the DC charger and the circuit breaker. Can both be deployed in a modern single phase installation?
Yes, however single phase Sigenergy still not approved for use in Australia as yet I believe.
Could you rerun this experiment (or the last disconnect under load one) with 10x38 fuses in suitable fuseholders to see if there is any benefit (or not) to using the old cartridge fuse method?
All current generation GM EVs support Vehicle to Home and it has been activated for use. At least in America, I don't know the status of the software in Australia.
Thats awesome, in Australia we are still waiting to be able to do V2H and V2G. As far as I know only the Nissan Leaf has the ability to do it in Australia as yet anyway. Apparently with Tesla though its just a different software that isnt available to us as yet either.
Thanks for the video. Do you have a website with prices for solar + battery packages ? I'm looking for quotes for a new system install in Hamersley WA 6022 thanks
Hi Thanks for messaging me on Facebook, for others reading this no I don’t have a website anymore and I don’t have a price list as such due to all jobs being unique. Please feel free to email me at jason@jeswa.com.au Cheers
We use the Black Clenergy Kits on all jobs, as it always looks better than the silver mids & ends next to black panels these days. Good video mate - would love to do a zoom interview or in-person interview and compare notes on products in 2025 :) I am from Wollongong NSW. :)
That was actually my one regret on this job and an oversight on my behalf to be honest 🤦♂️👍🏻
Wow, Australia regulations are like years ahead of UK solar regulations.
Could they have a DC coupled battery and put all the clipped kws in there, bypassing the inverter?
Absolutely with Solaredge yes
Had an interesting thing happen today with my 3P Sigen. One of the Grid phases dropped out. The system went to off-grid mode, and was running out of battery. Power company restored the phase before battery ran out, but I was getting worried. I wonder what would have happened at battery depletion. I'm assuming power outage. What's stopping the Sigenstor from charging on the remaining phases? I think it's something that should be added to the firmware.
Nice install buddy, good job. If they are only adding a couple of small motors, wouldn’t it have been easier, cheaper, maybe even better to just keep as a single phase setup and either change motors or smaller single to 3 phase inverters aren’t that expensive now, or VSD’s to the circuitry for those couple of motors? As a single phase setup, couldn’t they be set up so two inverters act as generators to the main inverter and the last could call on either generator or mains supply to make up any extra needs? You would still get your 15+Kva of single phase with the advantage of less idle power when needs are low, under 4-5Kva the other two could be idle &/or off until called up by the main inverter. Andy’s ‘Off Grid Garage’ demonstrates this type of integration with a 5Kva Multiplus 2 and a Phoenix 3Kva inverter acting as a generator to the Multiplus unit. Will Prowse has done reviews on the Ruixu Batteries and swears by them for build quality, features & price compared to so many other brands, says he can’t fault them, that should give you some confidence, he is not a sell out. Good vid & info. Cheers
When it comes to off grid, non grid tie inverters, all high frequency, transformerless inverters are shifty. They offer much shorter life expectancies and far poorer surge capacities. If you want an inverter that's going to last, then buy a low frequency, transformer based inverter charger.
Hey mate, great build. I just built my first system with two multiplus 2 8000's. It wasn't too difficult, like you say keeping resistance as even as possible with equal cable lengths. I had to learn the programming in victron bus configuration, there is a video on the Victron professional website that explains parallel and 3 phase setup pretty well.
What about the powerplus installation detail of making sure the existing and new battery are with a certain voltage range before turning the new one on?
Carefully use vise grips to hold the dynabolt thread end without burring and back off the nut. Use a prybar to lever under the washer to apply more sleeve locking force and at the same time try unthreading the nut all the way to the end of the thread. Use a centre punch with sharp hit to release the dynabolt. Clamp the sleeve onto the bolt thread with vise grips and pull out.
Yep tried all that, they were bound up and going nowhere. Thank you for the tips though 😊👍🏻
Hi, good vid, review and info. I did see a comment from Sigenergy on another video where they said, they like you to put a small roof over the inverter covers you were complaining about to cover this vent area as insurance against leaf or sticks, dirt, bugs, etc, getting into that vented area on top of the system, I can see why now, and agree with your comments. Cheers
I am always looking for good videos on breakers and solar stuff. This was a great video. thanks! earned a new sub
CE printed right on them (Chinese Export). Crap
Hi , I've just upgraded to fttp , so a new router Asus , the blue light is on at all , I tried the tapping ( like I was knocking on a door ) and pairing mode did not activate. Do I have to shut down and restart the inverter ? , and should I do this at night when the solar panels are inactive ? Thanks for the video too.
Hi The process needs to be done when the inverter is active during the day. Its important to knock in quick succession to get it in pairing mode. No restart should be required.
I stick a hose in there and it rinses the calcium out
Good idea
Of the 3 I have only 1 let go. This was when I pulled PV under load into 10KWH. Two $6 IGBT blew and it repaired fine. Mine don't have that much dust, but they have seen hundreds and hundreds of cycles of humidity and are basically mounted outdoors undercover. If you come across one used, they can be repaired, they do what they say they can do. Beware that they are hard on battery BMSs, so if you have a flaky BMS... These can exacerbate that and cause the BMS MOSFETs to short. Dally BMSs failed short on me while validating against these machines. This was while practicing sudden disconnects of battery and PV for safety checks. Overall I'm happy with Growatt for the Value
i wouldn't recommend housing in the sun or outside as heat can decrease the life span of the capacitors and dust tends to clog up the fans causing the mosfets to overheat and its fucks the entire system. i house my inverter indoors away from the elements and the heat.
Yes all good points 👍🏻
@@joondalupelectricalservice3201 also love the channel keep up the good work
Is this system automatic switch? I.e does it switch from on grid to off grid by itself and back if for example it detects that there is no power or unstable power on grid, so it switches to off grid supply and if the power is out on the battery, it either switches to on grid if there is power there or it directly inputs through the solar supply. Or if for example there is excessive energy after the battery is full? What does it do if it can no longer store that energy or send it into the grid?
Hi yes all automatic between off grid to grid tied. If the battery is full and there is no grid the system simply ramps down solar production.
The EV DC charger is too expensive. I can get 100k km of range on grid power for the price of the DC charger. That just doesn't make sense.
It makes sense if you want to charge from your own solar power, not everyone makes these decisions based on financial benefits 👍🏻
Also take into account its V2X capable, having a backup/off grid option to use your EV battery is a massive bonus
And sell power back to the grid at high peak power FIT prices with Amber with V2G
I think more people will seel this DC charging opportunity when the power providers move to variable export limits during the day, and you won't be losing out on the DC side of the system if your charging a car before conversion losses to AC. Will be looking into Sigenergy for my installations in 2025.
Amazing, thanks this helps me understand the power of DC loads
30 minutes? Try brevity. Brevity. Brevity. Brevity.
Great video - just for info the Kia EV's offer vehicle to load, although I've never tried this with my EV6.
Yes but only with a 240v adaptor power socket that you plug into the vehicle I believe👍🏻
Where are you. I have an issue with leak under solar …I am in qld Caloundra.
Sorry Im in Perth WA
You’re seniority in the solar felid is you’re experience !
They dont even recommend solar DC isolators anymore. Too much risk of improper installation.
I have a 3 phase string inverter with 8kw of panels and a second 6kw system with Enphase iQ7As. Can I get a Sigenergy battery without decommissioning my existing inverters
Yes, its called ac coupled solar and is measured with a ct and controlled via frequency shifting from the Sig inverter.
I have a little PV installing company in Argentina. I have sent 4 back. I had no problem with replacements but it's very annoying I think I had good luck that all the failures happened within the 2 years period.
This is a massive problem in coastal areas!!!
I’ve heard really good things about them. Edit… oh bollox… those bolts!
If you go into settings and tools, then app settings, then notifications, you can select Go-off Grid as an alert
Perfect thank you, I believe that may have just been added to the App.
Stainless steel they luv binding up
Hi. What’s the largest single phase inverter they have currently?
Hi 12kw single phase.
@@joondalupelectricalservice3201are the 8 and 10 kw inverters able to be installed in qld?
I have four 545 watt panels with a voc of 49.6 each. All in series going into my Ecoflow Delta pro ultra. Twice now I have had two inline 30 amp MC4 fuses fail. The fuse itself is fine. The contacts that touch the fuse fail. I feel safer with no fuse at all.
Great video, very informative. I am looking at getting a single phase home battery system, tossing up between the new Powerwall 3 batteries and the Sigenergy system. What was the capacity of the inverter you installed? Must have been one of the larger units to handle so many panels. I think that system you installed with almost 20kW of solar will still have a lot of power exported with the 8kWh battery or even up to 24kWh. In NSW we are limited to just a 5kW inverter on single phase.
Thank you. That one is 15kw three phase. Export limited to 1.5kw. If you are single phase and have an existing solar system I would go Powerwall2 still.
I'd be concerned about the escutcheon panel as well, and you don't want a fine because they supplied it with dodgy breakers.
A good very in-depth look. I disagree though the sungrow Sh15t(20,25) model inverters are three phase and do have UPS switchover of a slower 10 ms.
thank you I dont believe the Sungrow has the same capacity when islanding but I will check thank you
Have this setup now in Ireland and it brilliant if the grid go down I will still have power from the battery's well worth it.
They are awesome
Има някъква грешка в свързването.
Much prefer built in isolators
Generally speaking, unpolarized low-voltage DC MCBs and MCCBs (below 100VDC) are typically quite cheap, but once you get into higher voltage ratings you either have to spend a whole lot more money for an unpolarized DC breaker, or you have to use a (still cheap) polarized DC breaker. Polarized DC breakers contain magnets which direct the ARC into the arc chamber and must absolutely be wired correctly because the current direction matters in terms of directing the arc. The I.R. (interrupt rating) can be very low... solar panel strings produce very little current, so a breaker is perfectly acceptable *IF* it is wired correctly. There is a simple rule of thumb in terms of gauging DC breakers. You can use unpolarized DC breakers for low-voltage (e.g. battery DC busses) situations under 100VDC, and those breakers should generally be rated at least double your nominal maximum DC voltage. But any POLARIZED DC breaker you buy for the purposes of a solar disconnect had better be rated for 1000VDC or higher. Period, end of story. Do not use lower-rated polarized breakers for solar disconnects, ever. You can buy polarized 1000VDC breakers in MCB and MCCB formats for the purposes of implementing a solar string disconnect. Again, the interrupt rating (I.R.) is irrelevant for this application because solar panels cannot produce a whole lot of current. The best way to get it right is to buy a proper pre-wired combiner box that includes per-string fuses and a master breaker on the back-haul, even if you don't parallel any strings and even if the fuses are not needed. The "+" and "-" on polarized DC breakers are an indication of current direction, NOT POSITIVE OR NEGATIVE VOLTAGE. Current direction. The current direction goes from the "+" to the "-". There is no "line" or "load"... it might be marked, but it's not relevant. You must wire polarized DC breakers such that the current direction goes from "+" to "-". For battery DC wiring (under 100VDC), NEVER use a polarized breaker. The reason is because current can flow in either direction... there is no correct way to wire a polarized breaker in a battery system. Don't even use polarized breakers for situations, such as connecting up an inverter, where you know what the current direction will always be. Always use unpolarized DC breakers. -Matt
400vac does not equal 400vdc. AC breakers use the zero crossing point to extinguish the arc. DC does not have a zero crossing point a breaker or switch must be rated for or above the intended voltage and current. I think these are AC been re labeled as DC, I come to that conclusion as all relays and switches and relays I have come across always have a lower dc voltage rating.