HVACR AUS
Приєднався 28 жов 2022
Commercial HVACR technician from Melbourne, Australia.
Enquiries: hvacrtechaustralia@gmail.com
Enquiries: hvacrtechaustralia@gmail.com
Temperzone / 37kW Package Unit isn’t Heating the Space
Service call for this package unit not heating the space.
Переглядів: 1 060
Відео
Mitsubishi Electric / I Finally Return With The Bell Mouth Cowls
Переглядів 972День тому
It’s taken months, but I’ve finally returned to install the cowls on the YKB unit as a tester.
Daikin VRV 5 / U4 & E7 Faults
Переглядів 1,9 тис.14 днів тому
I attended site to replace the control board on a VRV 5 Heat Pump system after another tech had diagnosed it as faulty. There wasn't much information on the job notes so I decided to start from scratch.
Daikin / High-wall Split System Won’t Turn On
Переглядів 2,5 тис.21 день тому
Service call for this Daikin high-wall unit not heating a classroom.
Temperzone / More Issues With This 55kW Package Unit
Переглядів 2 тис.Місяць тому
Found this package unit to be displaying a fault condition on the BMS during a maintenance
Mitsubishi Electric / City Multi VRF 7102 Fault
Переглядів 1,7 тис.Місяць тому
Service call for this City Multi YJM Heat Recovery unit in a 7102 error code.
Daikin VRV II / Heat Recovery System Has Performance Issues
Переглядів 1,7 тис.Місяць тому
It was noted on a maintenance by another tech that this system wouldn't perform when all indoor units were running, but as they dropped out some this supply air temps were better.
A Few Jobs From Multiple Site: Ep 5
Переглядів 1,2 тис.Місяць тому
Job 1: Replacing two 12uf capacitors and investigating other issues on an older Apac Package unit. Job 2: Replacing a noisey indoor fan motor on a Mitsubishi Electric GA high-wall split system.
Daikin VRV 6 / My First Time Connecting the Type 4 Checker to a Daikin VRV R
Переглядів 1,9 тис.2 місяці тому
I was here to carry out port checks, add an additional 1kg of R410a and confirm correct operation of this new VRV 6.
Actron Air / Two New Package Units with E45 Faults
Переглядів 2,4 тис.2 місяці тому
I was the third person to look at these two newly installed 15kW Actron Air Package Units. Originally they were displaying an E60 fault.
A Few Jobs From Multiple Sites: Ep 4
Переглядів 1,2 тис.2 місяці тому
Complication video. Job 1: Replacing a faulty Skope fridge controller. Job 2: Setting fan speeds to two Actron Air Tri Capacity package units. Job 3: Replacing a faulty Hitachi ISPM (inverter) board. Enjoy.
EmailAir / Outdoor is a Block of Ice
Переглядів 1,7 тис.2 місяці тому
Everyone’s favourite ice block unit. This system is a hunk of junk. Retrofitted for a big AHU that serves an auditorium. Should be replaced but won’t be. I was sent to look into it after the supply air temps on the BMS were reading low despite saying all 4 stages were running.
Actron Air / Airflow Issues on a 71kW Tri-Capacity Package Unit
Переглядів 2,5 тис.2 місяці тому
Actron Air / Airflow Issues on a 71kW Tri-Capacity Package Unit
Temperzone / I Had the Replacement Outdoor Fan Only to Find the PCB Was Now Blown
Переглядів 1,4 тис.3 місяці тому
Temperzone / I Had the Replacement Outdoor Fan Only to Find the PCB Was Now Blown
Mitsubishi Electric / Leak Search on a City Multi PURY-YNW
Переглядів 2,3 тис.3 місяці тому
Mitsubishi Electric / Leak Search on a City Multi PURY-YNW
FCU isn’t Heating the Surgery Room
Переглядів 1,2 тис.3 місяці тому
FCU isn’t Heating the Surgery Room
Daikin / Compressor is Ramping Down After 10 Minutes
Переглядів 4,3 тис.3 місяці тому
Daikin / Compressor is Ramping Down After 10 Minutes
Temperzone / Replacing a Drive Pulley on a 65kW Package Unit
Переглядів 1,2 тис.4 місяці тому
Temperzone / Replacing a Drive Pulley on a 65kW Package Unit
Daikin VRV-S / New VRV-S System isn’t Heating the Space
Переглядів 2,2 тис.4 місяці тому
Daikin VRV-S / New VRV-S System isn’t Heating the Space
Daikin / 27kW Package Unit is Covered in Ice
Переглядів 4,3 тис.4 місяці тому
Daikin / 27kW Package Unit is Covered in Ice
Fujitsu Airstage / Pumping Down a 3 Pipe VRF to Add an Extra Indoor Unit
Переглядів 2,1 тис.5 місяців тому
Fujitsu Airstage / Pumping Down a 3 Pipe VRF to Add an Extra Indoor Unit
Apac / System Ran But Then Blew an Outdoor Fuse
Переглядів 1,7 тис.5 місяців тому
Apac / System Ran But Then Blew an Outdoor Fuse
Mitsubishi Electric / Fan Replacement on a PUHZ-YKM & Static Pressure Measurements
Переглядів 1,8 тис.5 місяців тому
Mitsubishi Electric / Fan Replacement on a PUHZ-YKM & Static Pressure Measurements
Mitsubishi Electric / Replacing the Outdoor Coil on a City Multi VRF
Переглядів 3,6 тис.5 місяців тому
Mitsubishi Electric / Replacing the Outdoor Coil on a City Multi VRF
Daikin / Repairing an E3 Fault on a Multi Inverter
Переглядів 3,1 тис.5 місяців тому
Daikin / Repairing an E3 Fault on a Multi Inverter
Mitsubishi Electric / City Multi VRF 6831 Fault Turned into a Lot More
Переглядів 2,8 тис.6 місяців тому
Mitsubishi Electric / City Multi VRF 6831 Fault Turned into a Lot More
Mitsubishi Electric / City Multi VRF Leak Repair - Part 3
Переглядів 2 тис.Рік тому
Mitsubishi Electric / City Multi VRF Leak Repair - Part 3
Mitsubishi Electric / City Multi VRF Leak Repair - Part 2
Переглядів 3 тис.Рік тому
Mitsubishi Electric / City Multi VRF Leak Repair - Part 2
Mitsubishi Electric / City Multi VRF Leak Repair - Part 1
Переглядів 1,3 тис.Рік тому
Mitsubishi Electric / City Multi VRF Leak Repair - Part 1
Thanks for the vid! Did you have to remove the line set? Or can u remove fan motor without having to remove the line set?
@hvacraustralia you have the part number for the new fan motor??
No worries mate. Yes, you can remove the fan motor without disconnecting the copper pipe work. I don’t have the part number sorry mate.
Did you mean to say that the washable filters are designed to be thrown away?
I can’t remember 100% what I said, this was filmed around 5 months ago. I probably meant to say, when they’re that impacted that the collapse inwards it’s time to replace them. We did clean them to get them through.
If you’re really in a pinch and can’t get 12uf, wire 2x 6uf caps in parallel and it will get you out of trouble, plus a lot easier to get your hands on them.
Dude looks very low all the way from CA turn it in to standard 😁
Awesome video. Just a thought ,to find out how and why the compressor failed,the oil return lines and oil filter can get blocked by the oil receivers.unsweat them and blow them out.there is one for each compressor.
Thanks mate, glad you enjoyed it. This particular job was quoted by another tech. I did confirm the oil return lines weren’t plugged after replacing the compressor. If I ever need to replace a compressor in a Daikin I’ll always replace the oil line too.
Why do you wear gloves all the time?
I started doing it a few years back because I had enough of all those annoying cuts you get. Initially it was weird, but now it’s feels weird without them.
I was actually inspired to wear gloves after seeing you wearing them. Initially didn't like the loss of dexterity but after a while it's not noticeable. It's a game changer no more cuts from coils fins and sharp bits of metal, with the added benefit of not having dry crack skin in the winter months.
It’s weird to start off with for sure, but you very quickly get used to it. I don’t notice they’re on anymore.
@@hvacraustraliaI bet the misso would lol
Good job tech
Thanks mate.
Sat on wood? 🪵 0:38
Yeah, it’s unfortunately very common.
that view is amazing
What's happened to the video quality. 720p?
I didn’t realise until somebody mentioned something, but this video and my latest one uploaded as SD. I film everything in 4K but it had to do with an upload setting that was determined by my wifi quality. I’ve adjusted that now so from next week HD and 4K will be available.
@hvacraustralia cheers legend
I know a little something something about air and the turbulence im feeling it from here. 😂 GL g that aint getting fixed.
Turning vanes help turbulence to get you a more stable static pressure down the duct but its still shite. That cowling not being there in the first place is a joke, one of the first questions we got asked in mitsi course 😂
😂 it’s fucked no matter which way to look at it. My last suggestion was to relocate the YKB and P Series units outside, turn the PUHY in the corner to face the wall with a similar set up to the other two and cut out that acoustics crap. Or remove the roof 😂
Maybe some guide vanes in the duct bend would help.
It would help for sire. If my static reading was closer to 60Pa we could have suggested it, but I don’t think vanes would drop it that much unfortunately.
In your company job vecancy is there ❤
Sorry mate, I don’t believe so currently. Are you based in Aus?
Given the static pressure increased, isn't that a sign that the airflow increased substantially? Still restricted by the outlet of the ductwork but it seemed like the cowl definitely helped
Yeah, 100% adding the cowl increased the airflow. My thought process for removing it after was that the units will decrease the frequency of the compressor to hit their target evap and condensing temps and have a lot of safety’s in place to protect the compressor. The fan motor doesn’t have those safety’s and if I left the cowl on with a static of 130Pa I didn’t know how long before the fan motor would be damaged pushing against that much of a restriction. The capacity of the units won’t be 100% because the unit won’t be able to ramp up the compressor but they shouldn’t lose another fan motor this way. This place isn’t quick on making decisions.
I think you should have tried measuring the static pressure farther along the duct, closer to the outlet sound muffler. If the static pressure is higher farther along the duct, it would indicate that more airflow is coming out of the unit. Even though it wouldn't align with the manufacturer's requirements, I think increasing its maximum airflow would greatly help the unit.
I did measure at multiple points the first time around without the cowl and there was a marginal difference in static measurements. From the reading I’ve done on this it does appear measuring either side of the fan within a meter or so is the correct spot. Regardless, I doubt any spot I measured would have given me a reading under 60Pa 😂
I take me previous comment back, you’re right. I should have measured further down the duct for a more accurate average reading. Cheers.
I forgot how marvelous that ducting was. Presumably running it straight up and out the roof isn't possible
It’s brilliant 😂 not straight up as the roof ridge is directly above it, but going out through the roof was my first suggestion to them.
The frustration is real, I feel ya
I’m done with this job 😂
Just started my HVACR apprenticeship. Can't wait to be as good as you. Love the content mate!!!!!!
Thanks mate, glad you’re enjoying the videos. Good luck with your apprenticeship. It’s a great trade.
Hey mate I bought the Avanti 3.5kw Mitsubishi split system package and it did not come with copper insulated pipes. Is that supposed to happen and I have to purchase a 3rd party? Thank you
Hey mate. Yes, that’s normal. You need to purchase the copper separately.
@@hvacraustralia Thank You!
manual says 24 hours microns test buddy
Mitsubishi Electric’s manual says 1h for their YNW HR units. In the end, I do what I can with what time I’m given.
I didn’t diagnose it “Apparently displaying U4 & wasn’t much details on the notes “ I feel ya mate hahaha Service notes “I went there and there was a blinking light so I quote for boards and compressor and a gas leak just be be sure hahahah
😂 it is like that sometimes. I usually just do some quick confirmation now wherever I go to something I didn’t diagnose at the start.
Nice one mate
Thanks mate.
Good thinking swapping over the blade.
Had the same thing with those indoor switches at an agecare place in another state. Annoying but always the first thing to check now.
"It's draughty!" *Turns switch off* 🤣
No one could tell me why it was off either 😂
I love VRV❤❤
They’re great fun to work on.
Handy tip If it had already been commissioned previously (knows its head count). You can click reset after 2 minutes and it will bypass the 15 minute initialisation, just don’t hold reset 👍
Ah that’s good to know! Thanks for sharing that mate.
hey mate do you think it’d be possible to check on your camera if you can do higher resolution video, it’d really make the videos look nicer
Thanks for brining this up. I film everything on the 4K setting but I’ve now realised there was a setting that determines the quality of the upload depending on my wifi connection. I’ve change this now. Annoyingly the next video will also be SD but after that HD and 4K will be back. Cheers mate.
Love my vrv's. Once you get a hang of things, they're super easy to work on
100%. The hard work at the start absolutely makes it worth it. A lot of fun to work on.
Excellent video and beautifully explained 👏
Thanks mate. Glad you’re enjoying it 🤙
Awesome work mate
Thanks mate.
Great videos mate ! Keep them coming 👍🏻
Thanks mate. Appreciate it.
My favourite Daikin series
Mine too mate! And I really like you. FVMA is my favourite too. I am on your page too! - Riley
@ yep Good to see another old girl go again
@@GeneralAvitation By girl do you mean me? - Riley
or the AC?
@@suezq74 no the ac
Love Daikin!
That brown mark around the connector pins is just flux residue from soldering. Sometimes connections on a PCB have to be touched up after the complete board went through automatic assembly (sometimes if the whole board is surface mount and there are just a few connectors they will just be soldered by hand). Nothing to worry about, as is is not conductive. You can clean it with 99% IPA or PCB cleaner and a brush.
That’s handy to know! Thanks for the tip mate. Appreciate it.
Nice video... Most likely a sneaky rat/bug for sure in this scenario. Well done on taking the time to actually pull things apart and testing them... Plenty of donkeys out there would just suggest replacing the whole unit with new. (Purely because they are inexperienced) Excellent work 🤙
Thanks mate, appreciate it.
come off it you slag. you struggle to connect your gauges to the unit, i have seen you
Hey mate Love your videos! Do most commercial premises have roof access or do you access by tall portable ladder? Thanks
Hey mate. Glad you’re enjoying the videos. Most places do have some form of roof access but I do also carry around an extension ladder just in case.
Had a horror story similar to this a few months back. Replaced a 25kw condenser water package unit for a comms room. After commissioning it would have this same issue but with the indoor fan. Would complete a cycle but then the indoor fan wouldn’t start up on the next 2 cycles as the thermal overloads were open causing the system to go out on LP and sometimes locking itself out. Had Temperzone onsite for it and even they were scratching their head. Was a nightmare for so many days we would rectify things and it would keep happening. So much sleep lost and anxiety just being close to the site. This head scratcher hits close to home
Oh man, I feel you on that one. Issues like that can drive you mad 😂 We’re Temperzone able to rectify the issue?
Seems like an electrical issue but also watch for oil leaking out the transducer body into the wiring loom where it clips on too.
I didn’t notice any oil but it will be something I’ll look out for. Cheers.
Killing the power corrupting some flash or other parameters causing the boards to misbehave maybe? Very odd…
This is my thought too. This entire site has power issues, but this is the only unit going through boards. Once they don’t need to isolate the unit to carry out testing and are no longer using a generator it will be interesting to see if the issues persists .
use a 9volt battery to test the fan motor. it will run at full load.
Insane tip
That’s a great tip! I’ve never thought of that. So simple. Thanks mate.
How would you determine the health of the fan motor by doing this ? Thanks
The UC8 board sends a 0-10VDC to the fan board which in turns sends AC power to the fan motor. If you have a fault control UC8 board you could send 9VDC to the fan board to get the fan to run, test amps, listen to bearings etc.
I guess all VRV6 are heat recovery actually That new service valve design is bad and will eventually leak. Why wouldn't they keep the traditional one with a cap?!
It’s an insane thing for Daikin to do 😂 good luck to them
Daikin vrv E3&E4 error liquid and gas pipe valve left to stope
I’m very interesting your experience and explain how to troubleshoot….thanks so much I’m in Melbourne Please update contact number
Thanks mate. Glad you’re enjoying the videos. I have an email linked to the page. Everyone is free to contact me there 🤙
Hi mate do you film using your phone or a camera the quality is so crisp?
Using my phone, but I have it set to 4K. Surprising how well it turns out.
Beautiful stuff to watch a professional at work, lovely stuff mate 🤙
Thanks mate.
Sometimes a reset is all you have to do and can do to fix a vrf
100%
Yeah. VRF is weird... So intelligent and so dumb at the same time 😂
Mine it show red on the controller,,when I restart it ,,,it goes back the way it was
Hi sir❤
I think mitsubishi is butter than daikin and Lg vrf.
Mitsubishi is my preference to work on.
Very nice troubleshoot. Greetings from Brazil. VRV II is kinda rare here these days but we hale a lot of III's and IV's (mini VRV's too)
By the way last month we came across a place that had 1st gen VRV running on R22! 20+ years installation
Thanks mate. It’s always nice to hear where people are watching! I haven’t seen a VRV1! Hopefully one day 🤞