HVAC Legend
HVAC Legend
  • 57
  • 92 569
Burnham Alpine Inducer motor and blower inlet assembly replacement
Replacing inducer motor and blower inlet assembly on a Burnham Alpine. The inducer motor was faulty however 9 out of 10 times the swirl plate is cracked so we quote that for the repair as well.
#hvac #hvaclife #hvaclove #hvacrepair #burnham #alpine #hotwater #plumbing #gasheater
Переглядів: 23

Відео

No AC. Capacitor replacement and coil cleaning
Переглядів 2,8 тис.21 день тому
No AC. Found a capacitor way out of range and a condenser coil caked with dirt #hvac #hvaclife #airconditioning #hvacmaintenance #hvacrepair #hvaccontractor
Frozen coil, diagnosing bad blower blower
Переглядів 60628 днів тому
Diagnosing bad blower motor after finding a frozen coil #hvac #hvaclife #airconditioning #hvacrepair
Compressor replacement on American Standard platinum heat pump
Переглядів 2 тис.3 місяці тому
Compressor replacement on American Standard platinum heat pump
Navien NPE heat exchanger replacement
Переглядів 1,2 тис.3 місяці тому
Navien NPE heat exchanger replacement
Nice boring video of a AO smith tankless being flushed!
Переглядів 643 місяці тому
Nice boring video of a AO smith tankless being flushed!
Why Is This Brand New Furnace Not Heating?
Переглядів 2,3 тис.4 місяці тому
Why Is This Brand New Furnace Not Heating?
No heat - Tripped rollout switch
Переглядів 4604 місяці тому
No heat - Tripped rollout switch
Burnham Alpine inducer motor replacement
Переглядів 1634 місяці тому
Burnham Alpine inducer motor replacement
Replacing expansion tank, water feed/ backflow, and leaking spirovent
Переглядів 9765 місяців тому
Replacing expansion tank, water feed/ backflow, and leaking spirovent
Tenant destroys boiler and almost catches house on fire!
Переглядів 715 місяців тому
Tenant destroys boiler and almost catches house on fire!
Don't let this happen to you: The consequences of neglecting gas furnace maintenance
Переглядів 6 тис.5 місяців тому
Don't let this happen to you: The consequences of neglecting gas furnace maintenance
How a worn out thermocouple ruined these people's night
Переглядів 1226 місяців тому
How a worn out thermocouple ruined these people's night
Clearing a Plugged Up Steam Boiler Made Easy
Переглядів 1156 місяців тому
Clearing a Plugged Up Steam Boiler Made Easy
No More Lockouts! Resolving the Constant Boiler Issue
Переглядів 646 місяців тому
No More Lockouts! Resolving the Constant Boiler Issue
Replacing control board on a Lochivar Knight boiler
Переглядів 536 місяців тому
Replacing control board on a Lochivar Knight boiler
Replacing baffles on an American Standard Tam9 air handler
Переглядів 496 місяців тому
Replacing baffles on an American Standard Tam9 air handler
Fixing a common issue on a goodman gas furnace - Replacing a leaking collector box and gasket
Переглядів 2,5 тис.6 місяців тому
Fixing a common issue on a goodman gas furnace - Replacing a leaking collector box and gasket
Multiple furnaces down in same home
Переглядів 297 місяців тому
Multiple furnaces down in same home
condensate neutralizer replacement
Переглядів 1977 місяців тому
condensate neutralizer replacement

КОМЕНТАРІ

  • @halilkayis1547
    @halilkayis1547 9 днів тому

    4y55tttttttt

  • @markh.6687
    @markh.6687 10 днів тому

    There's a spray can product at the big orange box store that you spray on the coils (let it sit on about 10 min.) and hose off, in case you don't want to use the on-hose cleaner. I did mine without even taking the case off...much better!

  • @samyz1660
    @samyz1660 12 днів тому

    Looking to buy the yellow adapter . Did you pushed it with something??? What you called it please. Any link ?

    • @Hvac_legend_
      @Hvac_legend_ День тому

      This is the kit I have. Not sure if they sell parts separately www.grainger.com/product/55NH69?gucid=N:N:PS:Paid:GGL:CSM-2295:4P7A1P:20501231&gad_source=1&gclid=CjwKCAjwhvi0BhA4EiwAX25uj3FTXSiN9tyr9bcPU3MMJCtzFhGdYon80_xzrjjmHSReRK34HLLUTRoCYkEQAvD_BwE&gclsrc=aw.ds

  • @Sunrise_HVAC
    @Sunrise_HVAC 16 днів тому

    I have to ask why you cut the damn coil out to replace a compressor??? I have done many of those a never had to cut the coil out. Invest in the NAVAC for swage tool. Worth every penny.

    • @Hvac_legend_
      @Hvac_legend_ День тому

      Just pull the coils when it's a tall unit, I'm short as hell so it's just easier for me. I've been eyeballing the swage and the bender. Think I'm gonna pull the trigger soon!

  • @ChaChingDream
    @ChaChingDream 20 днів тому

    I stoled your music and I'm moving to Nashville!

  • @bdr4625
    @bdr4625 20 днів тому

    WOW!

  • @bdr4625
    @bdr4625 20 днів тому

    Never seen one that dirty.

  • @zachpearman6556
    @zachpearman6556 20 днів тому

    What kind of sprayer are you using?

    • @Hvac_legend_
      @Hvac_legend_ 20 днів тому

      Not sure the exact name but it's by nu-calgone for the 4x bottles

  • @northwoodsliving101
    @northwoodsliving101 20 днів тому

    1000 dollars for capacitor and coil cleaning, Say its not so?

    • @Hvac_legend_
      @Hvac_legend_ 20 днів тому

      Think the whole bill was like 6 and some change including the diagnostic

  • @bearg4019
    @bearg4019 21 день тому

    Wow... Now that it's clean...customer should have a lower light bill..now that compressor isn't working so hard...awesome job

  • @Ben-iz9ud
    @Ben-iz9ud 21 день тому

    Probably should start showing you turn off the power lol.

    • @Hvac_legend_
      @Hvac_legend_ 20 днів тому

      Nope, I believe in natural selection. We need techs with brains anyway

  • @mustangmike6421
    @mustangmike6421 21 день тому

    Heard the song and knew he knew what he was doing😂😂😂

    • @jonathan_herr
      @jonathan_herr 20 днів тому

      To be thinking that that song is good music? Yech.

  • @chaseherigstad8576
    @chaseherigstad8576 21 день тому

    Careful with that nu-brite on that grass, they’re gonna be pissed when it’s all dead

  • @keithpreston7252
    @keithpreston7252 21 день тому

    Yes sir that'll be 500 buckaroos cuz gonna be cold cold now

  • @IH8URFACEH8ER
    @IH8URFACEH8ER 21 день тому

    Spine fin coils are water only. Nu-brite is way too strong.

  • @mikev.1034
    @mikev.1034 21 день тому

    👍🤙🤘😮

  • @user-su5ft8lc9q
    @user-su5ft8lc9q 21 день тому

    Glad you didn't step off the ledge, looks bit DANGEROUS

    • @Hvac_legend_
      @Hvac_legend_ 21 день тому

      Would have went and saw Dr. Summeroff

  • @Djcarp83
    @Djcarp83 27 днів тому

    Good old carrier heat exchangers, they keep us busy

  • @Djcarp83
    @Djcarp83 27 днів тому

    And they hate hard low volt wires, they want it to be shielded stranded wire

  • @Djcarp83
    @Djcarp83 27 днів тому

    Worked for a carrier dealer and installed many communicating Infiniti systems, the tech is cool but carrier is just all around bad design, many inverter issues, worst heat exchanger design ever, ecm inducers, many installation errors……we are a Rheem dealer now, phenomenal service records……it all starts at the install

  • @user-su5ft8lc9q
    @user-su5ft8lc9q Місяць тому

    What, i thought you couldn't stop a Trane

  • @StonedBarbiee
    @StonedBarbiee Місяць тому

    That’s called the we’re friends discount

  • @raultorres9231
    @raultorres9231 Місяць тому

    is it really worth all the time and effort taking all the metal and coil out just to swap the compressor?

    • @Hvac_legend_
      @Hvac_legend_ Місяць тому

      I only do it if it's a tall one that's a pain to reach down in. Really only adds 10-15 minutes

  • @ryannorton1278
    @ryannorton1278 Місяць тому

    How old is the unit? I’m assuming it’s the variable speed unit?

  • @ryannorton1278
    @ryannorton1278 Місяць тому

    How old is the unit? I’m assuming it’s the variable speed unit?

  • @TheHouseofSniffers
    @TheHouseofSniffers Місяць тому

    That will be $250 sir.

  • @ericcomfort6228
    @ericcomfort6228 2 місяці тому

    Is the outside condenser unit the same for a heat pump vs a regular AC system? I know the inside “furnace” unit is different.

  • @oilandfireguy1739
    @oilandfireguy1739 2 місяці тому

    Lol atleast you where ready! Haha i try to look at the label first to see if its a long shank. Atleast with the equipment i work on, tp valve on the side will be longer to get past insulation, if its op the top, it tends to be short and on a nipple

  • @YYZ88YYZ
    @YYZ88YYZ 2 місяці тому

    Mines just went at my house 7yrs after I installed it, sent me a new one 2-3days later from the 15yr warranty.

  • @turboskywalker9108
    @turboskywalker9108 2 місяці тому

    Too much work. I just remove compressor and braze it back in. No need to remove coil unless you cant reach down there

    • @Hvac_legend_
      @Hvac_legend_ 2 місяці тому

      Ive done it both ways. Short coils it doesn't make sense to remove it. Tall coils it makes life easier and takes maybe 15 extra minutes to cut it out and braze it back in after.

  • @modquad18
    @modquad18 2 місяці тому

    Man, an hvac guy used one of those crimp connectors on my filter/dryer and it failed massively about 4 mos later. Now my compressor is dead and he says it’s because the reversing valve musta got stuck in the middle. Is he BS’ing me?

    • @leviv2870
      @leviv2870 2 місяці тому

      Maybe but those press fittings are good if installed correctly, the pipe itself will split before the seals

  • @donmahone4847
    @donmahone4847 2 місяці тому

    As long as the clearance above the ac unit is 5’ or more, the airflow will not be increased in air pressure. That should last along time. IMHO

  • @Brooks.Mechanical.Electric
    @Brooks.Mechanical.Electric 2 місяці тому

    What refrigerant are you putting in the Bosch? Doesn't look like 410A bottle you got there. Has Bosch already started shipping them out with R32?

    • @Hvac_legend_
      @Hvac_legend_ 2 місяці тому

      It's 410, all our bottles the last 2 years or so have come gray. Even R22

    • @Brooks.Mechanical.Electric
      @Brooks.Mechanical.Electric 2 місяці тому

      @@Hvac_legend_ I thought that might be the case, but with all the changes these days, seeing that bottle got me worrying. Thanks for the feedback, take care!

  • @josecruz3237
    @josecruz3237 3 місяці тому

    Danfoss compressor to the field 😊

  • @brwnohno
    @brwnohno 3 місяці тому

    Why? That's an old r22 Trane!?!

    • @Hvac_legend_
      @Hvac_legend_ 3 місяці тому

      Nope, 410. Was only 7 or 8 years old and the compressor was under warrenty

  • @Djcarp83
    @Djcarp83 3 місяці тому

    Ya took the coil off to replace the compressor😅 then used a B tank…….typical Trane bs 😂 I would of had the compressor out and in in 15 minutes

  • @The1realro
    @The1realro 3 місяці тому

    Dude what size are those damn compressor bolts

  • @arianduran1725
    @arianduran1725 3 місяці тому

    Why do people keep calling brazing solder ?! It's not soldering 🚫. More heat , makes the difference. Less heat is soldering 😉

    • @Djcarp83
      @Djcarp83 3 місяці тому

      Facts, but in a lot of r22 systems still solder there connections because r22 system are under a much lower pressure then r410a, not me I braze everything or press it

    • @modquad18
      @modquad18 2 місяці тому

      Old habits hard to break

  • @mjethier
    @mjethier 3 місяці тому

    that american standard logo is so friggin old. are you that poor of a professional to not basically force someone into something more efficient and that cost less than the repair itself? or is th is work in a 3rd world country?

    • @joshuasims7357
      @joshuasims7357 3 місяці тому

      prob because it lasted that long to begin with. almost all techs ive spoken to have told me to fix my appliances til i cant cause the new ones wont last as long.

    • @albertodominguez150
      @albertodominguez150 3 місяці тому

      Very disappointed in your comments

    • @thomasmann3560
      @thomasmann3560 3 місяці тому

      How tf is changing a compressor more then replacing the unit?

    • @Hvac_legend_
      @Hvac_legend_ 3 місяці тому

      ​@thomasmann3560 I'm pretty sure the guys a troll account. Compressor was under warrenty and repair was thousands less than a new system

    • @mjethier
      @mjethier 3 місяці тому

      im pretty sure I've had my account for eons. I don't see the point in patching up hot garbage from god knows how many years ago. Prove me otherwise that the logo isn't from an oldschool American standard and I'll apologize. @@Hvac_legend_

  • @doms8903
    @doms8903 3 місяці тому

    Lucky if you get 10 -12 years from a pin boiler

    • @Hvac_legend_
      @Hvac_legend_ 3 місяці тому

      Ha manufacturered in 13, right in the middle of your range. Nothing is built to last anymore

  • @mikev.1034
    @mikev.1034 3 місяці тому

    👍👍

  • @Pipesolutionsinc
    @Pipesolutionsinc 3 місяці тому

    Dam don’t think I’ve seen that before

  • @Pipesolutionsinc
    @Pipesolutionsinc 3 місяці тому

    Looks like you have done this a time or two , why does the unit sit so high off the ground? ✌️

    • @Hvac_legend_
      @Hvac_legend_ 3 місяці тому

      Raising it helps keep it higher than snow and ice.

    • @ardoario4990
      @ardoario4990 2 місяці тому

      Great job. How much do you charge for a job like this with the compressor included? Thanks for sharing.

  • @mikev.1034
    @mikev.1034 3 місяці тому

    👍👍

  • @Djcarp83
    @Djcarp83 3 місяці тому

    It’s a shit design heat exchanger it holds way to much water as you can see it’s just gonna do it again, if you could clean the water while it’s in the heat exchanger it would eat through that bitch, we don’t sell many of those around my parts but I personally have a Rheem tankless and as long as I clean it once a year I’ve been good

    • @Hvac_legend_
      @Hvac_legend_ 3 місяці тому

      Not a fan of the brand period. This is 1st one I've done on a on demand but have done a million on the combis. Think it's 2015/16 almost every single one leaks and tech support tells you it's normal unless you argue with them

    • @terrelknowles6680
      @terrelknowles6680 3 місяці тому

      Did the original water supply line up with the new heat exchange unit because mine we had to cut it and weld the old and the new line together

  • @Djcarp83
    @Djcarp83 3 місяці тому

    People don’t understand how Acidic condensate water is out of a high efficiency furnace, I’ve seen it eat rubber hoses on pressure switches to breaking down drains when dummies use black iron and galvanized pipes instead of pvc

  • @mikev.1034
    @mikev.1034 3 місяці тому

    👍👍

  • @kenngo4539
    @kenngo4539 4 місяці тому

    Made in china ?

  • @Phasmomancer
    @Phasmomancer 4 місяці тому

    Why Is This Brand New Furnace Not Heating? "American Standard" Well there you go, theres the problem.

  • @charlespaine987
    @charlespaine987 4 місяці тому

    The prime rule of ownership , maintenance pay me now or pay me later . Part 2 pay me later is ALWAYS MORE EXPENSIVE and potentially deadly!