HVAC Talkshow and Review For Homeowners & DIY
HVAC Talkshow and Review For Homeowners & DIY
  • 16
  • 328 059
How to Install DIY HVAC Plenums (and Save $$$)
In this video, produced by Steve Nagy and Chris Cherry, viewers will learn how to construct supply and return plenums using a plenum kit. Opting for a kit simplifies the process compared to purchasing sheet duct board and assembling it, which often requires specialized tools and experience. These kits include all necessary components for assembly, and we recommend using 1.5” plenums for enhanced efficiency. An increasing number of companies offer custom options, requiring only the dimensions of the air handler.
It is important to understand the distinction between supply and return plenums, as they may vary in size. The supply plenum connects to the top of the air handler, allowing heated or cooled air to exit the unit, while the return plenum is always attached to the suction side of the cabinet. (filtered return air)
To learn how to rebuild your duct system, click here.
This video covers essential topics for reconstructing your duct system, including extending flexible ducts, installing duct collars, fitting cans and grills, and basic principles of flexible duct design.
ua-cam.com/video/tgAlKPDMZdk/v-deo.html
For guidance on increasing airflow, click here.
ua-cam.com/video/sNq3z5NIgMY/v-deo.html
Please note;
This video recorded for the purpose of educating viewers about HVAC flexible duct system and installation. No company provided us with free products.
greenworksac.com/ac-system-replacement/
greenworksac.com/repair/
greenworksac.com/duct-system-replacement/
greenworksac.com/duct-cleaning/
greenworksac.com/ac-tune-up/
greenworksac.com/robotic-duct-inspection/
Trane review
ua-cam.com/video/3irDwQKfH4o/v-deo.html
Tempstar review
ua-cam.com/video/R0aoPO_7cmI/v-deo.html
Daikin review
ua-cam.com/video/1DBe0ATFYeg/v-deo.html
Carrier review
ua-cam.com/video/Zjd3-Frkua8/v-deo.html
Rheem Ruud review
ua-cam.com/video/a_zuG0VEYmY/v-deo.html
Lennox review
ua-cam.com/video/S4jcOubV3Vw/v-deo.html
GREENWORKSAC/
#flexible duct system #diy #smarthomeappliances #ductsystem #hvac #tempstar #trane #lennox #hvaclife #goodman #daikin #americanstandard #homeimprovment #ductsystem #carrier #heatpump #hvac #airconditioner #rheem #ruud #hvactechnician #hvac #airconditioning #heatpump #efficiency #inverter #diy #minisplit #ductless #environment #heat pump #airconditioning#flexible duct system #diy #smarthomeappliances #ductsystem #hvac #tempstar #trane #lennox #hvaclife #goodman #daikin #americanstandard #homeimprovment #ductsystem #carrier #heatpump #hvac #airconditioner #rheem #ruud #hvactechnician #hvac #airconditioning #heatpump #efficiency #inverter #diy #minisplit #ductless #environment #heat pump #airconditioning #ductlessairconditioning #hvaccontrols #hvacschool #hvacduct #ductwork #renovation #homedesign #plenum
Переглядів: 75

Відео

Boost Your Airflow Like a Pro (and Why You Should) (4k) HVAC Tips
Переглядів 1,3 тис.7 годин тому
This video, created by Steve Nagy and Chris Cherry, demonstrates how to address poor airflow in flexible duct systems. The key concept behind this method is to redirect a portion of the airflow from the rest of the house to a room experiencing airflow issues. However, it's important to avoid upsizing a duct too much, as this can lead to excessive airflow in that specific room, depriving other a...
Repair Or Replace Your HVAC Flexible Duct System And Save a Fortune
Переглядів 3,6 тис.День тому
This video, produced by Steve Nagy and Chris Cherry, demonstrates how easy it can be to change or repair flexible duct systems. A key factor to keep in mind is the necessity of having an appropriate design in place. The introduction of flexible duct systems has revolutionized the HVAC industry; it is truly an ingenious advancement. The origins of this invention cannot be credited to a single in...
Is R32 Worth the Risk? HVAC Flammability Test HVAC (4k) No Joke!
Переглядів 13 тис.28 днів тому
In this video, Steve Nagy and Chris Cherry demonstrate the flammability of the new A2L refrigerant, R32, in comparison to R290. R454B shares a similar flammability profile to R32. Both R454B and R32 are environmentally friendly refrigerants, representing a significant step towards healthier climate conditions while enhancing the efficiency of Heat Pumps and Air Conditioners. Interestingly, we f...
Why Your Thermostat Is Not Accurate (4k) Genius Solutions HVAC DIY
Переглядів 1,1 тис.Місяць тому
Trivia; Which one of the smart thermostats was affected least by the hot wall temperature? One of those thermostats did really well to our surprise when we artificially warmed the wall cavity. Submit the right answer in the comments below by November 18th and win that thermostat. This video was created by Steve Nagy and Chris Cherry along with guest member Madeline D, for the purpose to demonst...
The Truth About The New R32 VS R410A Heat Pump Air Conditioner (4k)
Переглядів 92 тис.Місяць тому
Join Steve Nagy and Chris Cherry in this informative video as they explore the key differences between the phasing-out R410A systems and the new R32 Heat Pump Air Conditioner systems. Please remember, this video is intended solely for educational purposes. Daikin did not supply any products or offer compensation for this review. The new R32 system demonstrates enhanced quality and efficiency. W...
Why Your Thermostat is Costing You a Fortune (4k) And The Solution Anyone Can Do
Переглядів 56 тис.Місяць тому
In this video, Steve Nagy and Chris Cherry, alongside guest member Madeline D, demonstrate how cold or hot wall temperatures can affect thermostat readings. While digital and smart thermostats are generally considered more precise than older analog models, they can still deviate by as much as 4°F, as shown in this video. Not all but many homes experience wall cavity temperature variations due t...
Angry? Do This Cheap Trick To Get Colder And Warmer Air From Your Air Conditioner And Heat Pump
Переглядів 15 тис.2 місяці тому
This video is for educational purposes. Demonstrating how to maintain and clean an indoor coil, evaporator coil for Heat Pumps and Air Conditioners. It's essential to maintain a clean coil especially in the Air Handler. When it comes to heating and cooling capacity the indoor coil needs to be as clean as possible. To maintain its cleanliness it is much more important than the outdoor coil itsel...
The Low Cost Air Conditioner Heat Pump People Can't Get Enough Of (4k)
Переглядів 7 тис.2 місяці тому
This video was created by Steve Nagy and Chris Cherry along with guest member Madeline D, for the purpose to review this Goodman Air Conditioner / Heat Pump system. Air Conditioner System; Air Handler Model Number AMST36CU1400 Condenser Model Number GSXN4036 Heat Pump System; Air Handler Model Number AMST36BU1400 Condenser Model Number GSZB403610 Please note; Goodman, Daikin, Amana did not prov...
Know before you buy! Tempstar (ICP) Air Conditioning System Review. Model# N4A5S and FJMA4
Переглядів 8 тис.6 місяців тому
This video was created By Steve Nagy (guy with glasses) and Chris Cherry for the purpose to review this Tempstar (ICP) AC models. (official AHRI match) Please see our other review videos. ua-cam.com/video/5RpdQJn-NPA/v-deo.html 7 Major AC Brand Review ua-cam.com/video/Zjd3-Frkua8/v-deo.html Carrier AC Review ua-cam.com/video/S4jcOubV3Vw/v-deo.html Lennox AC Review ua-cam.com/video/3irDwQKfH4o/v...
Know before you buy! Daikin Air Conditioning System Review. Model# DX4SEA and AMST Air Handler
Переглядів 4,7 тис.6 місяців тому
This video was created By Steve Nagy (guy with glasses) and Chris Cherry for the purpose to review this Daikin AC models. (official AHRI match) Please see our other review videos. ua-cam.com/video/5RpdQJn-NPA/v-deo.html 7 Major AC Brand Review ua-cam.com/video/Zjd3-Frkua8/v-deo.html Carrier AC Review ua-cam.com/video/S4jcOubV3Vw/v-deo.html Lennox AC Review ua-cam.com/video/3irDwQKfH4o/v-deo.htm...
Know before you buy! Rheem RUUD Air Conditioning System Review. Model# RA14AZ and RH1PZ
Переглядів 16 тис.6 місяців тому
This video was created By Steve Nagy (guy with glasses) and Chris Cherry for the purpose to review this Rheem RUUD AC models. (official AHRI match) Please see our other review videos. ua-cam.com/video/5RpdQJn-NPA/v-deo.html 7 Major AC Brand Review ua-cam.com/video/Zjd3-Frkua8/v-deo.html Carrier AC Review ua-cam.com/video/S4jcOubV3Vw/v-deo.html Lennox AC Review ua-cam.com/video/3irDwQKfH4o/v-deo...
Know before you buy! Trane Air Conditioning System Review. Model# 4TTR40 and TEM4B0
Переглядів 6 тис.6 місяців тому
This video was created By Steve Nagy (guy with glasses) and Chris Cherry for the purpose to review this Trane AC models. (official AHRI match) Please see our other review videos. ua-cam.com/video/5RpdQJn-NPA/v-deo.html 7 Major AC Brand Review ua-cam.com/video/Zjd3-Frkua8/v-deo.html Carrier AC Review ua-cam.com/video/S4jcOubV3Vw/v-deo.html Lennox AC Review ua-cam.com/video/3irDwQKfH4o/v-deo.html...
Know before you buy! Lennox Air Conditioning System Review. Model# ML17XC1 and CBA25UHE
Переглядів 20 тис.6 місяців тому
This video was created By Steve Nagy (guy with glasses) and Chris Cherry for the purpose to review this Lennox AC models. (official AHRI match) Please see our other review videos. ua-cam.com/video/5RpdQJn-NPA/v-deo.html 7 Major AC Brand Review ua-cam.com/video/Zjd3-Frkua8/v-deo.html Carrier AC Review ua-cam.com/video/S4jcOubV3Vw/v-deo.html Lennox AC Review ua-cam.com/video/3irDwQKfH4o/v-deo.htm...
Know before you buy! Carrier Air Conditioning System Review. Model# 24SCA53 and FJ4DXB. It's Real
Переглядів 1,1 тис.6 місяців тому
This video was created By Steve Nagy (guy with glasses) and Chris Cherry for the purpose to review these Carrier models. (official AHRI match) Please see our other review video. ua-cam.com/video/5RpdQJn-NPA/v-deo.html 7 Major AC Brand Review ua-cam.com/video/Zjd3-Frkua8/v-deo.html Carrier AC Review ua-cam.com/video/S4jcOubV3Vw/v-deo.html Lennox AC Review ua-cam.com/video/3irDwQKfH4o/v-deo.html ...
7 Best Heat Pump and Air Conditioner Brands Apples to Apples Best HVAC Review (4k)
Переглядів 84 тис.7 місяців тому
7 Best Heat Pump and Air Conditioner Brands Apples to Apples Best HVAC Review (4k)

КОМЕНТАРІ

  • @christophercooke9376
    @christophercooke9376 3 години тому

    Good video, but also important if you can design or have location where you can get all the way around air handler to seal to plenum, otherwise might be impossible to completely seal all sides.

    • @GWAC555
      @GWAC555 3 години тому

      Correct! Sometimes they are very had to get to.

  • @wes2460
    @wes2460 16 годин тому

    My Parents had a 1976 Carrier round one Heat pump installed and never had one problem with it save for it needed cleaning on the outside. We replaced in 2008 with a American standard 20 seer 5 ton heat pump with twin reciprocating compressors in it. A 5 ton compressor and a 2.5 ton I think. The carrier was more reliable but the American standard has been very good. The inside coils had to be replaced in 2014 but they paid for it all and after that no problems. It runs always just about very rarely using the 5 ton compressor. I don't trust Trane/American standard anymore. They used to make there own compressors and there reciprocating compressors were bullet proof that why there prices were higher. Well I had to replace a Trane 14 seer compressor not long ago on my rental unit I own. It was a L.G. that was pulled out of it. I was mad as hell cause I was told that's why are prices are higher cause we make our own. Which was a lie . I confronted him about it and produced my recording of him telling me that, which I always do with contractors. My three year old Gibson heat pump fried itself and not worth repairing. I installed a Ruud 15 seer heat pump in my house(8900$). Well it sucks bad. They don't have a accumulator for a heat pump and no compressor belly band heater . Its very weak on heat and LOUD as hell.. I bought me a dirt cheap 18,000 btu Mini split heat pump for 700 bucks and installed it myself. My house has a open floor plan this mini split cools and heats my whole place just fine. It got 2 below zero here last winter this mini split keep the house at 69 F no problem.My power bill dropped 40 bucks a month this system is a 23 seer and is silent. NO more large systems that are loud and break and even if this mini only last three year at 800 bucks to replace the whole thing is a no brainier. I did it myself and took me about 7 hours . The heating and air guy wanted 5000 bucks to do it. Which I laughed at him , I understand making a profit but that was a ripoff .

  • @TedCookHVAC
    @TedCookHVAC 22 години тому

    I like this video.

  • @realSamAndrew
    @realSamAndrew День тому

    I noticed you took down the previous version of this video after i commented on the error in the CFM calculation. Or was it just my imagination? 🧐🤔

    • @GWAC555
      @GWAC555 День тому

      We truly valued your input and bringing the error to our attention. The mistake originated from the video editor. We strive for accuracy on our channel. Consequently, we promptly removed the video and reposted it with the correct CFM readings.

  • @wojtek-33
    @wojtek-33 День тому

    Only if the person who did my HVAC didn't seal all my ducts with a half of tub of sealant on every connection.

    • @GWAC555
      @GWAC555 День тому

      Certain building codes require that joints be sealed with mastic. Once sealed, the joints can be removed by cutting the dried mastic and peeling it back, a procedure we frequently undertake. If this process results in damage to the surface of the mixing box, plenum, or register box, (can) you may use spray adhesive to improve the bond between the surface and the silver tape.

  • @mobgma
    @mobgma 2 дні тому

    can you do a vid on pros and cons of CFM vs velocity? what matters in most houses? they often talk about this also in leaf blowers

    • @GWAC555
      @GWAC555 День тому

      That's a good subject. Maybe we should.

  • @billsheehy1
    @billsheehy1 3 дні тому

    Excellent advice. Thanks so much.

    • @GWAC555
      @GWAC555 3 дні тому

      Glad it was helpful!

  • @sophiegrisom
    @sophiegrisom 4 дні тому

    The whole flammability concern is absurd. Many houses have a natural gas meter near the compressor, but I guess the EPA never noticed those. I installed a 1.5 ton Della mini-split SEER 22 last Spring which came charged with R32. Made by Medea, like most Chinese brands. I bought to better use my solar energy, just heating and cooling the living areas, but the little guy cooled my whole 2200 ft2 house this summer, even on 110 F days. Good since my central AC died right after I got it running.

  • @BleedingEdgeHVACR
    @BleedingEdgeHVACR 9 днів тому

    The HVAC industry wasn’t ready for A2Ls when it launched outside the US, and it still isn’t ready today, the only circumstance when the refrigerants flammability is an issue is when techs aren’t using key best practices when brazing including; recovering into a vacuum, purging with nitrogen after recovering, CUTTING OUT ALL COMPONENTS NOT SWEATING OUT and flowing nitrogen when actively brazing. The problem is 99% of Techs aren’t doing these practices, which is going to result in igniting the refrigerant when brazing under some circumstances. Otherwise A2L refrigerants like R32 and R454B are fine.

  • @scottdoran2683
    @scottdoran2683 9 днів тому

    I don't like an upside down board you went the wrong way

  • @OnequestionTenrupees
    @OnequestionTenrupees 10 днів тому

    Jaquar heat pump E02 lack of refrigerant ERROR HOW TO FIX PROBLEM

  • @ChrisWachtman
    @ChrisWachtman 10 днів тому

    I'm skeptical, and I'd need to see some real world examples of hot or cold walls skewing temperature readings enough to cost "a fortune"

  • @dus10dnd
    @dus10dnd 10 днів тому

    I really dislike the practice of cutting the vent hole in the drywall and leaving the exposed drywall. Air quality is a much greater priority than ever, we should really be sealing up that drywall so that the dust isn't getting picked up by the vents. And for those that want to try and dismiss that concern, you're indeed incorrect. It is a big deal. Yes, there is a lot of dust within a home, including new construction or remodels, but things should also be cleaned far better to remove as much as possible. In addition, sealing air infiltration points from unconditioned spacing is important and that includes these vents, anyhow. Also, I think extra work should be done when extending a duct to ensure that overlapping insulation doesn't separate. Some tape internally and even a zip tie externally. Some movement or shifting when setting the duct or blowing insulation likely will mess it up, even if you've gone through a lot of effort to create "slack" internally. It also looked like you were going to handle it, but when you taped the duct to the collar, the perforation in the lip is exposed. I would have covered that with the tape. The outer tape isn't enough. For air quality, we're talking about microscopic particulates and fiberglass is not something you want in your lungs. And... some better beer. :) Overall a great video, I think you did a great job, it was just things that I get very nit-picky about. You've performed a great service to the community!

  • @user-cz8do7xl8u
    @user-cz8do7xl8u 10 днів тому

    to add, the only difference is to include but not limited to: 1. Its in an attic 2. you're crawling around on rafters 3. it's 100 degrees 4. its dusty, dirty and poor air flow, dead mice, rats and if you're lucky a raccoon 5. it's not at hip height, in a conditioned space and you can reach everything 6. you're swimming in insulation 7. you're wearing long sleeve shirts, mask, dickies trousers 8. You're working on sheetrock 9. Everything you touch is wet, because its 100 degrees and you're sweating on everything 10. Your drill battery dies 11. Your head mounted lamp keep slipping and then the battery dies 12. You're doing this for 3 days straight praying for a cloudy day or rain 13. You're going in and out through a scuttle in a closet 14. The customer wonders why this is taking so long and doesn't like you're playing 5FDP 15. The office gives you "Emergency" calls after you're done for the day because you're on-call 16. The office gives you calls because the customer specifically requests you. 17. The office gives you calls because the on-call guy called in for the day. Yea, okay.

    • @GWAC555
      @GWAC555 10 днів тому

      We've been through all of what you have said. That's why duct systems are expensive. (team member)

    • @realSamAndrew
      @realSamAndrew 10 днів тому

      100 degrees? Must be a crisp fall day in the off season.

  • @tbrown121172
    @tbrown121172 10 днів тому

    My old central ac just stop working. R-22 condenser with a date code of 1989. Compressor finally went. Be hard pressed to get that longevity out of a new unit

  • @joesimonetti
    @joesimonetti 10 днів тому

    Cool idea on the transition box...how do you know how big to make it? My system is 4 ton, 1600cfm but ducted for 1200 cfm, so I need to fix that. I was thinking of feeding 1 - 14" and 2 - 12" flex to 3 different zones of the house and build 3 transition boxes to feed all the room ducts. So...basically 700 and 480 CFM boxes, respectively. I was thinking 1 - 16"x16"x16" cube and 2 - 14"x14"x14" cubes. Would that introduce too much loss in the system?

    • @GWAC555
      @GWAC555 10 днів тому

      First; using a cube transition box is not a bad idea however, obtain a duct design done by a professional load calculation company and strictly go by that.

  • @neutrodyne
    @neutrodyne 10 днів тому

    What is the deal with the copper vs aluminum condenser? Why is aluminum better?

    • @thedeadlee690
      @thedeadlee690 22 години тому

      Cheaper for them to manufacture, the savings are not passed on to the consumer through.

    • @wes2460
      @wes2460 16 годин тому

      Dont get no aluminum micro coil they leak bad. Thats what my Gibson had in it and they suck...

  • @tommytommy7096
    @tommytommy7096 11 днів тому

    Hey great video i learned a lot.. i was taught that insulation and a good contractor that is knowledgeable makes a systems last a long long time…..

  • @muhammadrezafahlevi7000
    @muhammadrezafahlevi7000 12 днів тому

    Recommended Daikin AC that uses R32 or R410? please help me answer because I want to install AC.

  • @emilepmartin
    @emilepmartin 13 днів тому

    Awesome job gents...enjoy the content, keep it coming!

    • @GWAC555
      @GWAC555 12 днів тому

      More to come!

  • @dus10dnd
    @dus10dnd 13 днів тому

    I think the only notable things on the new unit... it is R-32... and the fan blade. The other changes are simply incremental engineering changes that could have happened on a revised R-410a unit. I do think that 15" of overlapped coil is rather odd. Why not more? Why not less? I suspect the driving concern is storing it in a warehouse and shipping; that allows the unit to be slightly smaller which helps in those circumstances. It really doesn't matter for installation. Now the fan blade. That is cool. There are have been two major advances in propellers in the past few decades and I was hoping that they would make their way to our systems: 1. Toroidal blades: this is the innovation I really want to see. they're much more efficient and even quieter, by far. 2. Serrated trailing edge: this is mostly considered a way to make the movement quieter, but noise is the expression of energy, so the quieter it is, the more efficient it is. I'd like to see both. EDIT: So, I replaced my old AC with an ASHP last year when it died. I am really happy with the system. It was just a drop in replacement... I kept my gas furnace as the air handler and for backup heat. A significant contributing factor to the failure of the AC was the zoning system and a failed damper... and a failed temperature sensor in the zoning board. So, I have been to get rid of all of that and just get a 2nd unit for the upstairs. I was initially rather concerned about R-32. I still have some reservations, but I think I am ready for one. I was going to get an identical R-410a ASHP, but with an air handler, since it would be net new. Since it will be for upstairs, I think R-32 makes a lot of sense. The biggest reservation I have about R-32, still, is having it next to my gas burner for the furnace. Since I won't have this for the upstairs unit, R-32 seems like a no brainer. I am in an area where we get extended periods of below zero (fahrenheit) temperatures in late January and early February, so backup heat is super important to me, even though my ASHP seemed to work fine (I had the thermostat set to burn gas when it was below 5F overnight so I didn't wake up to a freezing house in the event that I somehow messed with my install... it was fine). Perhaps my concerns will prove unwarranted with two separate units and the improved performance of R-32.

  • @AbdicateDotNet
    @AbdicateDotNet 18 днів тому

    great educational video!! music + speech = hard to understand...

  • @zq12900
    @zq12900 18 днів тому

    Sir which is the safest gas for ac inverters

  • @robertmitchell832
    @robertmitchell832 20 днів тому

    With the open flame, you need to allow the gas to fill the chamber to reach the flame.

  • @AmericanPatriots87
    @AmericanPatriots87 20 днів тому

    Does it make sense to do both?

    • @GWAC555
      @GWAC555 20 днів тому

      It could but the clingwrap works just fine.

    • @AmericanPatriots87
      @AmericanPatriots87 20 днів тому

      @@GWAC555 so just doing the cling wrap is sufficient and the other is diminishing return? I have leftover bubble insulation would that work fine as well?

  • @skidivr
    @skidivr 21 день тому

    Had a daikin dealer give me some estimates today for 410 and 32 fit systems. they have an incentive now for the 410. im hoping to be able to hold off and get this 32 system you are showing. why didn't the rest of the industry use 32?

    • @GWAC555
      @GWAC555 20 днів тому

      GWP on the R454 is lower

  • @erbterb
    @erbterb 21 день тому

    We need larger fans for more efficient air flow. More air per kW. We need stacked pump mediums. One medium in the circuit inside/outside and a second medium in an inside/inside configuration. It is heat pumps all the way from absolute zero to the heat of the sun.

    • @GWAC555
      @GWAC555 20 днів тому

      Impressed! Great info

  • @stefanstix5176
    @stefanstix5176 21 день тому

    The concentration of the r32 was too high to be in the range of explosive mix. Between 13,5 and 27%Vol in air it is explosive. Below and above it's not. Try that again with 20% Vol.mix in Air 🤪

  • @pokeyt9241
    @pokeyt9241 22 дні тому

    I believe the statement was made that all the thermostats could be calibrated / adjusted for readings. I know at least the Nest thermostat has no adjustment to readings. The Ecobee does. Also, thermostats such as Nest and Ecobee can have their temperature swayed by how long the display is on. I know since I have both. Not sure of the others. Years ago I had a Honeywell LCD that had the option to keep the backlight on low level and it would throw off the reading by a degree or two.

    • @GWAC555
      @GWAC555 21 день тому

      Yes! Great observations.

  • @jakubhecko9872
    @jakubhecko9872 23 дні тому

    What do you mean by this video.. Europe is basically canceling R32 very soon

  • @hovercraftmk2
    @hovercraftmk2 23 дні тому

    Sensi

  • @P.R.Shriram
    @P.R.Shriram 23 дні тому

    What about silicone putty instead of clingwrap? Definitely more insulative, dielectric, won't trap moisture between its layers over time and you shouldn't need to disconnect wiring

  • @Chevytech1977
    @Chevytech1977 23 дні тому

    Have you done a comparison between R-134a and R-1234yf yet? Id love to see those

  • @janmo519
    @janmo519 24 дні тому

    Nobody buys R32 if you can buy R290.

    • @GWAC555
      @GWAC555 22 дні тому

      This is the reason why.... ua-cam.com/video/I04H_irTH24/v-deo.html

  • @Dream244
    @Dream244 25 днів тому

    This could be all resolved by just manufactures placing the temperature gauge as an external antenna on the thermostat.

    • @GWAC555
      @GWAC555 24 дні тому

      Yes. We know for sure that manufacturers are trying to solve this issue and constantly improving temperature accuracy. Someone will come up with the solution.

  • @John-vh1fk
    @John-vh1fk 25 днів тому

    My thermostat is in my bedroom and being an ecobee, having the ceiling fan on messes with the algorithm that accounts for the heat it produces. The main reading is always off so I have to set it to ignore the main thermostat and use the room sensors.

  • @macleanclassics
    @macleanclassics 25 днів тому

    So put the thermostat in the center hall, with the least windows. And no direct sun

  • @NYCHvac
    @NYCHvac 25 днів тому

    Loved this video ! I thought of making one like it and now I don’t have to lol my take away is that they are both flammable. Idc about “mildly “ because that’s like saying someone is mildly pregnant. I saw fire on both.

    • @GWAC555
      @GWAC555 25 днів тому

      Well said. We all need to be more careful from now on

  • @aspinthereddragon9302
    @aspinthereddragon9302 25 днів тому

    its difficult to do this when your air handler is in the attic

  • @christopherreus7799
    @christopherreus7799 26 днів тому

    Your point being? Government Gona do what there Gona do point final!!

  • @Ace707xtc
    @Ace707xtc 26 днів тому

    Madeline has an absolute dump truck

  • @carpecanem611
    @carpecanem611 26 днів тому

    Before making the change starting at 13:26 (foam in the wall), I urge you to verify that the area between the studs is NOT used for return air. Blocking this flow could alter the temperature in the room that this "duct" is attached to.

    • @GWAC555
      @GWAC555 26 днів тому

      The main idea is to seal the wall so that air from the wall cavity does not leak onto the thermostat. “As mentioned above, a low volume of air was circulated in the wall cavity. The team did it in a way that it didn’t affect the air temperature in the studio. The cured foam wasn’t blocking the air circulation at all. Please see the IR photo at the end of the video. It’s clearly visible that the foam behind the wall remained at room temperature (bright orange color), while the surface of the wall was blue, representing a cold wall surface." (team member)

  • @MichaelAmen316
    @MichaelAmen316 26 днів тому

    Digital Psychomotor $85.00? YIKES!

  • @carlmorgan8452
    @carlmorgan8452 26 днів тому

    Does it matter what it reads What is comfortable matters 🤔

  • @jstaffordii
    @jstaffordii 26 днів тому

    CO2 is the best option for consumer. Been used commercially for decades but will never happen because HVAC industry will lobby governments against it. Gas is obtainable without a license fo $3/lb.

    • @GWAC555
      @GWAC555 22 дні тому

      We agree with you!

  • @wtfman5313
    @wtfman5313 26 днів тому

    How about the exploding refrigerators! LOL! Personally, I'm convinced that all this climate change talk is BS and we're all being grifted by the industry so they can develop new expensive garbage to peddle more frequently. R-12, R-22 and R-502 were the best refrigerants ever made and systems lasted decades. Now, you're lucky to get 10 years. It's a shame people are so gullible and just go with the flow and allow these groups to mandate these BS regulations without absolute proof it's necessary and I think history will prove that the climate hoax was just smoke and mirrors for profit. It's the middle of August here in Augusta, Ga. and it's currently 64 degrees at 6:22 am and the high is only going to be around 85. I had hotter summers in the 70's, 80's and 90's.

    • @GWAC555
      @GWAC555 26 днів тому

      R32 Flammability Test m.ua-cam.com/video/Nnz4ODMyOJ8/v-deo.html

  • @wtfman5313
    @wtfman5313 26 днів тому

    Evaporator coils are crap today. I'm tired of changing them personally (thank God I'm about to retire), but I wonder if R-32 is flammable enough to ignite in a home where the evap coil pops a leak in a smokers house while they're smoking or lighting up?

    • @guytech7310
      @guytech7310 25 днів тому

      I don't believe R-32 will blow up. R-290 (propane) & R600 (butane) definately are. I think R-32 needs a flame source to burn & cannot do a sustain burn by itself.

    • @casemodder89
      @casemodder89 20 днів тому

      ​@@guytech7310excellent information ! R32 needs over 600°C to burn and dies off without a constant ignition source.

  • @jackmen4
    @jackmen4 26 днів тому

    Today I did my first R32 mini split system at my company here in Southern California. R410A is officially over. We aren’t going to be buying any more inverters with 410A

    • @johnnysoup
      @johnnysoup 22 дні тому

      What is the pricing difference between the 2 types if same seer 2 rating? Thanks

  • @skidivr
    @skidivr 27 днів тому

    what are your thoughts on the Daikin thermostats? I heard they can be a problem. ???

  • @leweezo33
    @leweezo33 27 днів тому

    very informative and entertaining

    • @GWAC555
      @GWAC555 24 дні тому

      Glad you enjoyed it