How to wire 3phase 30 Amp disconnect
this video illustrates how to wire up a 30 Amp disconnect. please be sure to turn off all power before you get started.
Переглядів: 3 376

Відео

How to test and reset a GFCI outlet
Переглядів 3292 роки тому
This video explains how to test and reset a GFCI outlet. The video also explains the purpose of GFCI outlets.
How to reset a tripped curcuit breaker.
Переглядів 1032 роки тому
This video explains how to reset a tripped circuit breaker. If you have lights or outlets in your house that suddenly stop working, it is most likely due to a tripped circuit breaker. Learn how to reset a tripped curcuit breaker.
How to pull wire for a single pole switch.
Переглядів 5553 роки тому
This video explains how to pull wire, particularly non metallic sheathing cable, for a single pole switch. The video explains the 2 different ways that this can be done. The video also explains how to install a single pole switch.
How to install a 3 wire range outlet.
Переглядів 134 тис.4 роки тому
This video explains how to install a 50amp 3 wire range outlet.
How to install a plug for an extension cord
Переглядів 1,9 тис.4 роки тому
This video explains how to install a plug on the end of an extension cord.
How to install a 4 prong range cord
Переглядів 13 тис.4 роки тому
This video explains how to install a 4 prong range cord.
How to install a 3 prong range cord
Переглядів 6 тис.4 роки тому
This video explains how to install a 3 prong range cord for a stove or a range.
How to install a 3wire 30amp dryer outlet
Переглядів 338 тис.4 роки тому
This video explains how to install a 3wire 30 dryer outlet ( specifically in residential, using romex in a plastic box.)
How to install a 2 lamp ballast ( for T5 lamps)
Переглядів 11 тис.4 роки тому
This video explains how to replace and install a 2 lamp ballast, specifically for type T5 lamps.
HOW TO INSTALL A 4WIRE 30 amp DRYER OUTLET
Переглядів 18 тис.4 роки тому
This video explains how to install a 4wire dryer outlet. It informs the viewers that the wire size, and where and how to terminate each of the 4 wires.
How to install a 4 way switch
Переглядів 6064 роки тому
This video explain how to install a 4 way switch in a circuit that is wired using romax cable.
How to install a 3way switch
Переглядів 1785 років тому
This video explains how to install a 3 way switch, particularly in a house that is wired in romax. It specifically shows where each wire lands.
How to wire 3way switches using romex cable.
Переглядів 2,5 тис.5 років тому
In this video, I explain how to wire a set of 3way switches using romex cable ( I explain one way it can be done). There a different way you can do it. The video also talks about where 3ways are normally located and where they are needed.
How to use and read a receptacle outlet tester
Переглядів 55 тис.5 років тому
This video explains how to use, read, understand and troubleshoot using an receptacle outlet tester.
Determine the circuit color in a 3phase panel (divide by 6)
Переглядів 11 тис.5 років тому
Determine the circuit color in a 3phase panel (divide by 6)
How to install an A. C. Disconnect
Переглядів 323 тис.5 років тому
How to install an A. C. Disconnect
How to install a dimmer
Переглядів 1037 років тому
How to install a dimmer
Pushing or Pulling mc cable through metal studs
Переглядів 19 тис.7 років тому
Pushing or Pulling mc cable through metal studs
Explaining a parallel circuit
Переглядів 1027 років тому
Explaining a parallel circuit
How to install a 120volt GFCI outlet and install a regular outlet on the load side of the GFCI
Переглядів 5177 років тому
How to install a 120volt GFCI outlet and install a regular outlet on the load side of the GFCI
EXPLAINING A SERIES CIRCUIT
Переглядів 747 років тому
EXPLAINING A SERIES CIRCUIT
How to install a 120volt receptacle outlet
Переглядів 1107 років тому
How to install a 120volt receptacle outlet
HOW TO INSTALL A SINGLE POLE SWITCH IN A PLASTIC BOX
Переглядів 1,8 тис.7 років тому
HOW TO INSTALL A SINGLE POLE SWITCH IN A PLASTIC BOX
HOW TO PERFORM AN ELECTRICAL 3 POINT TEST
Переглядів 4 тис.7 років тому
HOW TO PERFORM AN ELECTRICAL 3 POINT TEST
HOW TO USE AN OHM'S LAW CIRCLE CHART
Переглядів 4,1 тис.7 років тому
HOW TO USE AN OHM'S LAW CIRCLE CHART

КОМЕНТАРІ

  • @Wissahickonwild
    @Wissahickonwild 5 днів тому

    Thank you for this

  • @dwaineruthannarmentrout1811
    @dwaineruthannarmentrout1811 12 днів тому

    Great video explaining all the details along the way. Thanks so much for taking the time to show all steps.

  • @MFD541
    @MFD541 16 днів тому

    2025 and you still ROCK! THANKS!

  • @LongDenis
    @LongDenis 17 днів тому

    Very helpful. Thank you

  • @SSJBAINS209
    @SSJBAINS209 18 днів тому

    Thank you for this 🙏🏽

  • @SISONHOMESTEAD
    @SISONHOMESTEAD 25 днів тому

    Great video!

  • @FernandoRodriguez-ds5ri
    @FernandoRodriguez-ds5ri 28 днів тому

    Wrong size box!?

  • @JohnnyRogers
    @JohnnyRogers Місяць тому

    This was very helpful. Thanks! so much!

  • @alijordanx8954
    @alijordanx8954 Місяць тому

    The wire going to the black common screw is coming from an 14/2 power source?

    • @rickyjewett6082
      @rickyjewett6082 Місяць тому

      @alijordanx8954 yes. On one of the 3 way switches, the wire going to the black common screw is coming from a 14/2 power source. On the other 3 way switch , the black common screw is coming from the light.

  • @kensmith9431
    @kensmith9431 Місяць тому

    One of the better videos on this. I think he should have shown tape on the back of the outlet, rather than just talking about it. Minor point though.

  • @hectorestrada2462
    @hectorestrada2462 Місяць тому

    Thanks very helpfu 😮

  • @YayboeSea-s4y
    @YayboeSea-s4y Місяць тому

    What If There Is No Ground Or Neutral Wire?

  • @tannercasper3177
    @tannercasper3177 Місяць тому

    Great vid super helpful

  • @miltonnegron65
    @miltonnegron65 Місяць тому

    Excellent video

  • @OwenPeterson-i8o
    @OwenPeterson-i8o 2 місяці тому

    Very nice job explaining the steps in this video. So the ground wire does not need to be connected at the outlet or the box? Why do you not cut it in the outlet box? Is that in case you need it for a future 4-prong? Appreciate it!

  • @CD-hc5ds
    @CD-hc5ds 2 місяці тому

    Hello A quick question about the ground wire. If your working withe a metal box instead of plastic, would you attach the bear ground to the metal box?

  • @WeldorLife
    @WeldorLife 2 місяці тому

    many people do great videos and this is one of them / a very good video, i appreciate it, very educational; a big help.

  • @Lindora01
    @Lindora01 2 місяці тому

    Wow! This was the very best explanation and video that I've seen yet! Great job sir! Can you make a video on how to add new Amp and wire to panel?

  • @RussPrince-f6n
    @RussPrince-f6n 2 місяці тому

    Very good and easy to follow

  • @edwardpolite88
    @edwardpolite88 2 місяці тому

    This is the Best Video I have seen on UA-cam explaining "line and the load", and "240 vs. 120" and where everything should land properly and to read the directions of course. Thank you!!

  • @jimmyhenry1891
    @jimmyhenry1891 2 місяці тому

    How about putting black tape on the white line side wire?

  • @ThodEssmann
    @ThodEssmann 2 місяці тому

    Thank you for this clear organized explanation. It was exactly what I needed. I didn't know what to do with the ground. The tape suggestion was really helpful. Thanks again.

  • @jesusmartinez2573
    @jesusmartinez2573 2 місяці тому

    Very good explantion

  • @1TakeDay
    @1TakeDay 2 місяці тому

    Thank you

  • @briinicholee7362
    @briinicholee7362 3 місяці тому

    What if you don’t have the red wire ,just black and white

  • @StrongLikeBullTV
    @StrongLikeBullTV 3 місяці тому

    Great video.

  • @spelunkerd
    @spelunkerd 3 місяці тому

    For those who think this is easy, you should know that the old NEMA 10 series plugs like this one have been illegal for new installations since about 1996 in the US. Appliances built before then were designed for buildings that did not have a dedicated ground circuit, so they used the neutral wire to carry ground faults. It will work, but it is potentially dangerous because the frame of the appliance may have some voltage on it caused by the imbalanced 120V loads. The NEMA 10 series were replaced with NEMA 14 series which have 4 wires, or NEMA 6 series which have three wires but no neutral (in those the third wire is a ground, not neutral). You don't want to be using a NEMA 6 plug on an appliance that runs some 120V circuits since the ground wire would end up carrying the unbalanced load back to the panel which is also illegal. NEMA 6 plugs are designed for appliances that don't require the use of 120V circuits to power oven lights, accessory plugs, or circuit boards. To tell which plug your appliance requires, check the wiring diagram and installation manual for the appliance. If it is a relatively new appliance, you probably don't want NEMA 10 receptacles! If the appliance supports a dedicated ground wire the most versatile and safest option is to use a NEMA 14 plug and receptacle AND be sure any ground/neutral bonding strap inside the appliance is removed. The 4 wire configuration of the NEMA 14 series is the direction almost all new appliances are moving to, and older plugs may be flagged during home inspections.

  • @forgivenandredeemed9460
    @forgivenandredeemed9460 3 місяці тому

    Excellent video...your a great teacher too!

  • @calvinbarnes7664
    @calvinbarnes7664 3 місяці тому

    I had 4y Outlet at my rental property date change it to a 3-wire I did not know until they moved out and lift it hanging black trash I am also black I own the house

  • @kyleenaustin2981
    @kyleenaustin2981 3 місяці тому

    This was so well done and useful!

  • @Sparky-ww5re
    @Sparky-ww5re 4 місяці тому

    Very clear and concise, you would make a good instructor at a trade school. Just my opinion, for a 100% complete guide to 3 light testers you need a total of 8 outlets. In addition to the 6 shown here, there is a condition where only the red light is lit. Ideal is the only manufacturer I'm aware of that lists this problem, but it is called hot on neutral with hot open. It simply means a hot/neutral reverse with an open neutral. The last condition is where all 3 lights are lit, usually with one light brighter than the other two. This occurs when the outlet is connected to 240V or something considerably more than 120V, either the result of a lost neutral on a multiwire branch circuit or possibly at the panel or the utility connection to the building, or the wrong outlet was installed, for example a standard 120V/ 15 or 20A duplex outlet could have been mistakenly installed for a larger window air conditioner that requires a single 240V/20A outlet.

  • @jodyshaw9043
    @jodyshaw9043 4 місяці тому

    thank you sir great video!!

  • @wackojacko1997
    @wackojacko1997 4 місяці тому

    That was good and to the point. Question: If I take the bare ground wire and clip it to the outlet plate (keeping it away from the two hots and common), would that not be safer? If for some odd reason one of the hot leads came loose in the box and touched the outlet plate, the presence of the ground would trip the breaker, and otherwise (absent the ground), the plate would be energized at 110V were someone (child) to touch the plate (I know, this is a really unlikely scenario). I did clip my ground to the plate, and I"m wondering if there's any specific danger I'm missing by doing this. I have a 3 wire outlet.

    • @surferdude642
      @surferdude642 4 місяці тому

      No, you need a 4 wire receptacle attaching the ground wire to the ground contact on the receptacle. Then use a 4 wire power cord, designed for this purpose, and attach the wires to the appliance per the instructions. The ground and neutral wires will be separated. The neutral wire connects to the neutral on the appliance and the ground wire connects to the metal frame.

    • @wackojacko1997
      @wackojacko1997 4 місяці тому

      @@surferdude642 I see my mistake, and I'm correcting it. Thank you.

  • @WICKEDPRO210
    @WICKEDPRO210 4 місяці тому

    Can the red go on the white plz let me no

  • @tommygunnzfrank3207
    @tommygunnzfrank3207 5 місяців тому

    Lol I had the nippers on the ground ready to cut it off

  • @tysebai
    @tysebai 5 місяців тому

    Well understood, No confusion, one thing at a time. Thank you?

  • @Codeman785
    @Codeman785 5 місяців тому

    My question is how in the world did you get the wire into that box? Mine will absolutely not fit those tiny romex slots. I'm going to have to drill out a hole.

  • @jasonwildbunch
    @jasonwildbunch 5 місяців тому

    Thanks bud it helped

  • @mariehailey6738
    @mariehailey6738 5 місяців тому

    Thank you, thank you, thank you!

  • @caidiaz9454
    @caidiaz9454 5 місяців тому

    Thank you sir.

  • @AdlerNicolas-l1l
    @AdlerNicolas-l1l 5 місяців тому

    Great Video for all level in installing an AC Disconnect

  • @AyhamMubeen
    @AyhamMubeen 5 місяців тому

    Great job Brother ❤❤❤❤

  • @davidstellwagen1073
    @davidstellwagen1073 5 місяців тому

    Violation of NEC 250.140(B) that allows 3 wire says "... if an equipment grounding conductor is not present in the outlet or junction box...". So that section doesn't apply, you have to use a a four wire receptacle in compliance with 250.140(A), and change the cord per appliance manufacturers instructions.

  • @davidw64us1964
    @davidw64us1964 5 місяців тому

    Ty for having this video

  • @luisvega74
    @luisvega74 5 місяців тому

    Thank you thank you so much. It helped me a lot. I just moved to a new home with a different outlet on the dryer and appreciate your help. Be grateful and God bless you.

  • @joel5466
    @joel5466 6 місяців тому

    It was really helpful!

  • @tutubito08
    @tutubito08 6 місяців тому

    Very good and clear explanation. Thanks

  • @richinman7774
    @richinman7774 6 місяців тому

    Since it is 240v shouldn't you use 10/2 Romex????? Asking for a friend...

    • @rickyjewett6082
      @rickyjewett6082 6 місяців тому

      @@richinman7774 that depends on the amperage size of the equipment. If the amprage size of the equipment is 20 amps or less, you can use size 12 romax.

  • @oodavidyyf8416
    @oodavidyyf8416 6 місяців тому

    Nice video but if it was 120v. How would that wire to the box.

  • @parkerjohnson5420
    @parkerjohnson5420 6 місяців тому

    Should wrap your white wire with some red tape to signify 240. I think that’s code.

    • @rickyjewett6082
      @rickyjewett6082 6 місяців тому

      @parkerjohnson5420 yes. That is true. Thank you.