Ultrasonic angle probe v2 block calibration by using olympus epoch 600
Вставка
- Опубліковано 30 лис 2024
- in this video I have explained about following calibrations
and how to use the olympus epoch 600 flaw detector
exit point
range calibration
verify the angle of beam & sensitivity
very good sir
Navigation Pas is good or Knob Configuration which is good for site work and Training
Thanks for the video sir
Most welcome
good
good very usefull
Thanks for your helping..
Please make for VI block calibration....
Also defects and how to sizing
Thanks shortly will upload
V2 block 70 degree angle prope calibration hole of depth 8mm or 7.5 mm?
7.5 mm
How to change in to mm please tell me sir
Please send video DAC 19 mm SDH Block olympus 650 machine