Going by standards, its much appropriate to switch through the phase than having phase and neutral present in the same switch box, so 1 and 4 are better for me.
Method 1 and method 4 is exactly the same thing, only the switch is swapped around. Likewise with Method 2 Method 5 and Method 6 is exactly the same thing. Method 3 is something else
and if we will try it for two way connection from two different places it will operate only one off and one on but the same time if we will off the both switch it on the bulb will remain glow so where is two way connection in all the 6 types of wiring
Felicitaciones por el Diagrama.
Really good information
Going by standards, its much appropriate to switch through the phase than having phase and neutral present in the same switch box, so 1 and 4 are better for me.
Real information, nice bro. 👌👌👌👌👌👌👌👌👌❤️❤️❤️❤️❤️❤️👍👍👍👍👍👍👍👍👍👍👍👍👍👍
Thank you so much 😀
I think method no 4 is best
Very good and help full
சூப்பர் பிரதர் 🌹🌹🌹
Nice👍
Good sir but i would like to ask can we give neutral wire to switch ?
Yes, of course, one of the connection.
Does exchanging the two nodes has effects while we're connecting the two switches....?
there will be an ON/OFF switch position
Change
No1 is using kerala
Method 1 and method 4 is exactly the same thing, only the switch is swapped around. Likewise with Method 2 Method 5 and Method 6 is exactly the same thing. Method 3 is something else
In Spain this long commute is prohibited. In some modern mechanisms short circuits occur when activated. Regards.
Good.thanx
Good Sir ❤❤❤❤
Thank you!
You're helping me thanks
Very helpful and presentation bhai ❤❤❤❤
thanks
👍👍silent and most effective explaination.
which type is better..?? Reply
Type 2
Wrong
Type 4
Very good 🎉
Thanks for the visit
Nice sir
Type 4 is best
Thank you for your clear presentation, what if you incorporate advantages and disadvantages if there is any of each method over the other?
Good
Also helpful video..
Can it work on water pump
Type 2 suitable for water pump?? Genuine Reply
Which method will save wire.
Type 2
Type 2... But not safe
👏👏👏👏👏👏👏
Hey mujhe koi aisa diagram btao ek taraf normal switch ho aur dusri side 2 way switch ho
2no method is working but mcb down same time
❤❤❤🎉
For AC type 1 = type 4 and type 2 = type 5 = type 6.
Only two types wiring...
Yes your are right, just connecting node changed top and bottom wise
and if we will try it for two way connection from two different places it will operate only one off and one on but the same time if we will off the both switch it on the bulb will remain glow so where is two way connection in all the 6 types of wiring
I think mathod two is not good because fase and nutral are one switch i think it is not safe and long lasting conection
Why
Sem question
R u electrician? This is wrong.
Boom 💥🤯
How it is wrong
Video 5 , tắt đèn pha nóng vẫn còn
not wrong two of them i experienced practically
You need to know everything about Electricity and it's equipments😮😮😮@@PhuongTran-yd1lv
Type 4 easy way like
Types 3 method is waste any one light on the position
😂😂😂😂 so dangerous N and L in one switch
Why?
If the button fails it will short-circuit
Type - 2 is risky
nalla
Type 1 = Type 4 Circuit ✅
Type 6 = Type 5 = Type 2 Circuit ⚡️ Risky but it works.
Type 3 ❌ it's not 2 way switch circuit 😂
bhai g type 2 me to phase phase mil kr bulb ko ura hi dega..ye galat wiring h....
It's only three types why are you tell it's 6 types
You're just making it looks like 6 diagram. But 1 & 4 are the same and 2,5,6 are also the same? sorry mate
No 6 methods
only 2 useful methods
Wrong connection.one side of the bulb should be from phase.phase should be connected to the switch centre pole.
Type 3 is not a 2 way switch
connection wrong
Y
no one connection is right its either two on or two off in all the 6 types
Only 3 method
But you show 6 method
You are .,.....
दो मैथड 5 बार बातला रहे हो।
First method is ok remaining method's not safe and you're repeating same this is foolish
Only 2 types
Time waste
काहे बुरबक बना रहा है बे
Don't give wrong ideas
Starting the dots at the neutrals is very mis-informative. Pretty useless video.
wrong connection
Remove this vedio