ANO ANG TAMANG MAIN BREAKER.

Поділитися
Вставка
  • Опубліковано 4 лют 2025
  • ANO ANG TAMANG MAIN BREAKER.
    youtube.com/@S...
    branch circuit breaker,circuit breaker,ano ang tamang main breaker sa bahay,paano mag install ng circuit breaker,15amp circuit breaker,20amp circuit breaker,paano magsize ng circuit breaker ng aircon,paano mag install ng circuit breaker para sa aircon,circuit breaker for 1hp aircon,ilang watts ang kaya ng single circuit breaker,how to install circuit breaker for aircon,50amp main circuit breaker,ano ang tamang wire para sa ating breaker?paano mag compute ng load,paano magcompute ng electrical sa bahay,paano mag compute ng breaker,paano mag compute ng circuit breaker?,paano magcompute ng load schedule,magcompute ng electrical sa maliit na bahay,paano magcompute ng schedule of load,ano ang tamang main breaker sa bahay,paano mag compute ng outlet,paano mag compute ng aircon load?,paano gumawa ng load computation para sa main circuit breaker/,paano mag compute ng 1.5hp aircon unit?

КОМЕНТАРІ • 210

  • @teacherperry8514
    @teacherperry8514 28 днів тому +1

    Twice niyo po i multiply yan sa 80% kaya ganyan ang naging computation ni sir sa pangalawang way nang pag compute. Tama po yung ginawa nyang computation.

  • @xyboarge515
    @xyboarge515 Рік тому +2

    Salamat po

  • @MrMIXMAGIC
    @MrMIXMAGIC 6 місяців тому +9

    naguluhan ako sabe mo kunin 80% lahat ng CB so tama na ung 44A para sa 20A, 20A, 15A. Bawat isa na may 80% total nila is 44A.... di mo na need i multiply sa 80% ung result ng tatlo.

    • @jasonromero3248
      @jasonromero3248 2 місяці тому

      Tamara ma nga

    • @teacherperry8514
      @teacherperry8514 28 днів тому

      Tama computation niya. Dmo lang naintindihan. Yung 2nd way ng computation nya need mo yan i multiply ng twice sa 80% para makuha mo yung tamang sagot.

  • @dj3tv442
    @dj3tv442 Рік тому +2

    Hi sir pde ba ung 15 amper size 12 wire na breaker?sa electricfan dalawa,3 ilaw heather at rice cooker

    • @SAYDETV
      @SAYDETV  Рік тому +1

      Pwede tamang tama lang yang load mo.

  • @josedelacruz4069
    @josedelacruz4069 Рік тому

    Thanks for sharing bro new subs

    • @SAYDETV
      @SAYDETV  Рік тому

      Welcome po salamat 😊

  • @JojoCruzSolano
    @JojoCruzSolano Рік тому +3

    sir diba na compute mo lahat ng breaker kada isa sa 80 percent sagot mo 44 ampere computin pa uli yan 44percent sa 80 prcent.

    • @SAYDETV
      @SAYDETV  Рік тому +2

      Pinakamadaling paraan lang yan na sa breaker lang magbase, load computation kung marami kang appliances.

    • @bonweslly
      @bonweslly Рік тому +4

      Same question.
      Panu kung sabay sabay ginamit at naconsume mo ung 44 amps or kahit 40 amps nalang.
      Edi baka di kayanin nang main?

    • @kuyanoltv8516
      @kuyanoltv8516 11 місяців тому +1

      Mataas na ang 44A na consume, almost 10% lang ma consume

    • @fandulan
      @fandulan 9 місяців тому +3

      yan din ang point ko. nka .8 na lahat bat mag x.8 ka pa sa main. dapat yan total na lang yan. simple math.

    • @iashtiheal5491
      @iashtiheal5491 9 місяців тому

      Naku mali pala yung alam ko, kala ko e-total ko lang lahat ng branch tapos kunin yung safety factor na 20% para sa main, dahil inisip ko kung sabay2x ang gamit ng load sa bawat branch baka ho mag ooverload. At mag ttrip yung main.
      Marami pa pala akong dapat malaman. Salamat boss

  • @darwinmiranda1029
    @darwinmiranda1029 14 днів тому

    Boss ilng amp ung main. poso, outlet, at saka sa ilaw.

  • @st.gabriel3406
    @st.gabriel3406 5 місяців тому +1

    un iba mas mataas AMP mas ok dw..un pag compute ng consuming device po sna watts pra malamang ilan AMP sa ilaw, outlet ganun

  • @RaulLopez-tw8xn
    @RaulLopez-tw8xn 11 місяців тому +1

    Sir o.k. lng po ba kung nabaliktad Ang breaker?

  • @joselitoabcede8826
    @joselitoabcede8826 День тому

    2x kna ngbawas ng .80 percent.

  • @NBA.mix143
    @NBA.mix143 Місяць тому +1

    Nice sir panu pag 60ampere sir ang ilagay?

    • @SAYDETV
      @SAYDETV  Місяць тому

      Tataas din ang load na pwede ilagay

  • @robertourbino9168
    @robertourbino9168 9 місяців тому +1

    kung 84amp po ipan po dapat ang main sa😊lsmat po sana masagot nyo po

  • @rasheediverson3169
    @rasheediverson3169 4 місяці тому +1

    Pag naglagay ka ba ng outside breaker, typically yung box sa baba ng metro, kailangan pa rin bang lagyan ng breaker yung Main ng Panel Board sa loob ng bahay?

    • @SAYDETV
      @SAYDETV  4 місяці тому

      Kailangan po mas importante po ang main breaker sa loob ng bahay, sa kahit wala na yon.

  • @Luisito-i7i
    @Luisito-i7i 4 місяці тому +1

    Brother now ko lng nkita video mo kya now lng din nkapanood,, sa outlet ano ano ba ang dapat gmitin na appliances at sa aircon anong hp puwede salamat

    • @Luisito-i7i
      @Luisito-i7i 4 місяці тому

      20amp.c breaker mo,at sa outlet 20amp din Bro

    • @SAYDETV
      @SAYDETV  4 місяці тому

      20A po na breaker sng para sa mga outlet sa loob ng bahay at sa airon depende po sa hourse power (hp) ng aircon, 1.5hp na aircon =30A breaker, pag bumaba sa 1.5hp 20A na na breaker, pag mas mataas sa 1.5hp message ka ulit mas mataas na breaker na dyan

  • @PrincessZyraSultan-yw8tn
    @PrincessZyraSultan-yw8tn 8 місяців тому +1

    Tanong lang po 30a ang main breaker 9 ilaw appliances tv, washing dryer tpos may 20a cb pra sa ac ok lng po yun

    • @SAYDETV
      @SAYDETV  6 місяців тому

      Ok lang yan kaya yan na 30A

  • @ZuperZaiYen
    @ZuperZaiYen 2 місяці тому +1

    Pano po pag special outlet, 1 outlet sa washing area at un isa outlet sa refregerator sala area. 30 amp ba or 20amp ggamitin boss?

    • @SAYDETV
      @SAYDETV  2 місяці тому

      20A lang pag outlet, pag special outlet 30A kung 1hp na aircon pataas ang isasaksak mo

  • @CatherineZaragosa-wv1jw
    @CatherineZaragosa-wv1jw 24 дні тому +2

    Sir ok lang ba may sarili breaker yung ref ko 30amp

    • @SAYDETV
      @SAYDETV  23 дні тому

      Ok na ok po safe yan 👍🏿

  • @robertpascua1941
    @robertpascua1941 9 місяців тому +1

    Thank you broth😊er

    • @SAYDETV
      @SAYDETV  6 місяців тому

      Thank you too

  • @Iantot89
    @Iantot89 12 днів тому +1

    Lods may nabili kasi kaming bahay...mga 15yrs n sguro edad nung bahay...eh napansin ko ung mga wall outlet nya 15a 125v lang...ok lang b un?or mas amgandang palitan ng 15a 250v?

    • @SAYDETV
      @SAYDETV  9 днів тому +1

      Kung ok pa naman wag mo na palitan ganon ang mga lumang outlet per butas yan 125v kabilaan 250v

    • @Iantot89
      @Iantot89 8 днів тому

      @SAYDETV thank u boss..nalinawan n Ako..Tanong ko na din Po...may Isang outlet Ako dto na 50v lang ang reading sa tester..ano Po Kya problema nun...direct ko Po xang chineck sa wire nya...

  • @relampagosrahmes5
    @relampagosrahmes5 10 місяців тому +1

    Sir puede 20A gamitin para sa ilaw at puede ba mag sabay ng isang outlet sa apat na light switch?

    • @SAYDETV
      @SAYDETV  10 місяців тому +1

      Pwedeng pwede po may video tayo nyan

  • @rickyozon729
    @rickyozon729 2 місяці тому +1

    Ano size ng wire idol pwd sa 40amp main OK lng ba ung #10wire sa service entrance

    • @SAYDETV
      @SAYDETV  2 місяці тому

      #8 po para sa 40A, kung #10 ay 30A

  • @silenceplay7276
    @silenceplay7276 3 місяці тому +1

    Ano po ang tamang main breaker sa 60.8? Total na po lahat yan sa 30A+30A+20A+15A?
    Sa main ba 60A ba gagamitin o mag 70A na ako?

    • @SAYDETV
      @SAYDETV  3 місяці тому +1

      60A lang gamitin mo dyan kasi hindi nman ok lahat ng breaker mo full load yan at ang appliances mo hindi rin sabay sabay ang paggamit

    • @silenceplay7276
      @silenceplay7276 3 місяці тому

      @@SAYDETV marami pong salamat

  • @ellaganerecacho
    @ellaganerecacho 5 місяців тому +1

    Ilang amp breaker po ba ang pwede sa safari na submeter? Ang gamit eh. Electric fan, 2 cellphones, washing , dryer, booper, ilaw, rice cooker, mini rice cooker dreepor.

    • @SAYDETV
      @SAYDETV  5 місяців тому

      60A pwede na dyan sa mga appliances mo

    • @ellaganerecacho
      @ellaganerecacho 5 місяців тому

      @@SAYDETV talaga ba? 60amp? Daig ko pa may aircon at ref nyan.

  • @minimalist8477
    @minimalist8477 5 місяців тому +2

    Bkit di mo n lng kunin total load then multiply by 80%

  • @edcelrodriguez6796
    @edcelrodriguez6796 Рік тому

    lods sa outlet po ba kasama na po ba jan yung mga e.Fan at washing??ty po

    • @SAYDETV
      @SAYDETV  Рік тому

      Oo kasama na dyan,

  • @kidoskids2019
    @kidoskids2019 11 місяців тому +1

    sir pwede koba pagsamain ang dalawang aircon sa 40anp ?

    • @SAYDETV
      @SAYDETV  10 місяців тому

      Pwede piro 1hp lang na aircon

    • @sheryllmelandres-d2c
      @sheryllmelandres-d2c 8 місяців тому

      ​@@SAYDETVboss kapag dalawang aircon 1.5 po pasok parin po b 40 ampere main breaker

  • @RubenBarrogo
    @RubenBarrogo 4 місяці тому +1

    Kulng ung paliwanang di malaman Kung ilang ilaw at outlet ang pwede.

  • @chilltv9079
    @chilltv9079 2 місяці тому +1

    Dalawang beses mona minultiply sa 80%

  • @boytabirao6029
    @boytabirao6029 19 днів тому +1

    E paano po kung 3 aircon at isang heater ilan ang amperahe ng main breaker

    • @SAYDETV
      @SAYDETV  16 днів тому

      100A pwede na

  • @israelisaga4817
    @israelisaga4817 6 місяців тому

    Tanong lang idol...baguhan lang
    20A = 16A
    20A = 16A
    20A = 16A
    15A = 12A
    = 60A
    ×.80
    = 48A
    Anong breaker ang mas malapit sa 48A para sa main breaker at anong size ng wire para main breaker...sana masagot..salamat...

    • @SAYDETV
      @SAYDETV  6 місяців тому

      Kung hindi mo na dadagdagan ang load mo pwede ka gumamit ng 40A, piro kung sakali may additional na load o appliances gamit ka na lang ng 60A or 50A kung makakita ka ng 50A

    • @israelisaga4817
      @israelisaga4817 6 місяців тому

      @@SAYDETV salamat lods...keep sharing your knowledge..

  • @jayyu8373
    @jayyu8373 3 місяці тому +1

    Pano sir kung 16 branches yung panel box? Pano ang computation? Siyam na 30amp, dalawa 15 amp, dalawa 20amp ? Ang nakuha sa computation is 217.6 amp. Paki sagot po.

    • @SAYDETV
      @SAYDETV  3 місяці тому

      Pwede ka dyan gumamit ng 200A pwede rin 150A depende sa load mo

    • @jayyu8373
      @jayyu8373 3 місяці тому

      @@SAYDETV d b po masyado ng mataas 200amp sir?

  • @galaxyunicorn6170
    @galaxyunicorn6170 6 місяців тому

    Tanong lang sayde tv.pàano kung dalawa o tatlong aircon tapos may electric cooker at electric oven? Sana mabigyan mo ako ng kasagutan salamat

    • @SAYDETV
      @SAYDETV  6 місяців тому

      100A ang gamitin mo na main breaker tapos ang sa aircon 20A bawat isa, 20A rin sa ibang mga outlet at 15A para sa ilaw

    • @galaxyunicorn6170
      @galaxyunicorn6170 6 місяців тому

      @@SAYDETV salamat sa iyo saydetv.

  • @salahudinsatar-ke1zg
    @salahudinsatar-ke1zg 10 днів тому +1

    Sir goodday po, sir kapag 10 branches po ung gamit kong panel board,
    MB. - 20 amp
    20 amp - 20 amp
    15 amp - 15 amp
    20 amp - 20 amp
    20 amp - spare
    Anu po pwding gamiting MAIN BREAKER sir.

    • @SAYDETV
      @SAYDETV  9 днів тому +1

      100A na main pwede na, hindi nman sabay sabay ginagamit na mga appliances at hindi rin full load ang mga breaker

    • @salahudinsatar-ke1zg
      @salahudinsatar-ke1zg 9 днів тому

      @@SAYDETV salamat po sir newbee pa KC ako sa larangan Ng electrical,

  • @merlitojose2021
    @merlitojose2021 Рік тому

    Magandang araw bosing magtatanong sana ako sir kasi itong tunnel vent poultry nmin nakaka ground pag hinahawakan itong mga pintuan niya sir steel plate itong mga pintuan niya sir ano kaya dapat gawin sir para maalis ang ground nitong mga pintuan niya..salamat sir godbless

    • @SAYDETV
      @SAYDETV  Рік тому

      Nasagot ko na to sa isa mong tanong.

    • @merlitojose2021
      @merlitojose2021 Рік тому

      Hindi ko mahanap sir kung saan banda yong vlog mo na may sagot

    • @merlitojose2021
      @merlitojose2021 Рік тому

      Ok na po sir nahanap ko na salsmat ulit godbless

  • @rastybongalosa1657
    @rastybongalosa1657 6 місяців тому

    Sir pwede po ba ako mag install ng bahay ,,kung marunong nmn ako,,kahit walang certificate ng nc2😅

    • @SAYDETV
      @SAYDETV  6 місяців тому

      Pwede piro kailangan pa aprovan mo license elect. or engr. Kung sa bahay mo ok la din

  • @rebarz3523
    @rebarz3523 8 місяців тому +1

    Sir paano mag compute ng amphere para sa watts na gagamitim natin

    • @DaniloMunez
      @DaniloMunez 8 місяців тому +1

      Ok lang ,,

    • @SAYDETV
      @SAYDETV  6 місяців тому

      P=Power/watts
      I=Current/amps
      V=Volt/voltage
      Formula
      I × V = P
      P ÷ I = V
      V ÷ P = I

  • @AllenAcierto
    @AllenAcierto 11 місяців тому +1

    Lods yung breaker ko 16A sa ilaw tas 20A sa outlet ilan amp. Ang main breaker ko nito.kasi pag compute ko 23.04A

    • @AllenAcierto
      @AllenAcierto 11 місяців тому

      20A po ba gagamitin ko na main breaker or 30A na.sana mapansin.salamat

    • @SAYDETV
      @SAYDETV  10 місяців тому

      30A gamitin mo dyan kasi 23.4 ang load mo, maganda yan para nagtitrip kagad pag may problima sa load mo

  • @JunFabros-n1z
    @JunFabros-n1z 3 місяці тому +1

    Sir 30amp ang main ko pwede pa po ba ako magdagdag ng 30amp din at 20 amp. may ref poako tv computer at washing gamit ko

    • @SAYDETV
      @SAYDETV  3 місяці тому

      Pwede, 30A main tapos ang branches mo 20A para sa mga outlet at 15A para sa mga ilaw

    • @JunFabros-n1z
      @JunFabros-n1z 3 місяці тому

      @@SAYDETV sir pwede po ba pagdugtungin ang solid wire sa 10mm na strand

  • @FernandoCo-h6w
    @FernandoCo-h6w 5 місяців тому +2

    Paano kapag ang lumabas is 57.6? Ang ggamitin kb is 60amp?

    • @claribelvelasco1957
      @claribelvelasco1957 4 місяці тому +1

      Yes po un kasi pinaka malapit na measure. Pag 50amp nman mababa po

    • @FernandoCo-h6w
      @FernandoCo-h6w 4 місяці тому

      @@claribelvelasco1957 pwde kb sya lagyan ng 100amp? Para sa main

    • @FernandoCo-h6w
      @FernandoCo-h6w 4 місяці тому +1

      @@claribelvelasco1957 kumukurap kasi ung ilaw pag nag bbukas kmi ng aircon

    • @SAYDETV
      @SAYDETV  4 місяці тому

      Hindi main breaker ang problem nyan, dapat ihiwalay ng supply ang aircon, hindi dapat kasama sa mga outlet sa loob bahay kasi ganon ang mangyayari

  • @ronaldmaratas3224
    @ronaldmaratas3224 Рік тому +1

    Sir may anim ako na sewing machine250 watts 1/3 hp VAMP 1.97 ang mga motor po ilang amp po ang gagamitin ko na CB at ilang amp naman po ang main CB ko po
    Salamat at more power sa channel mo..

    • @SAYDETV
      @SAYDETV  Рік тому

      Ilang house power 1hp ba at 3hp or 1.3hp?

  • @SmilingClipperButterfly-zt4wi
    @SmilingClipperButterfly-zt4wi 5 місяців тому +1

    👍👍👍👍👍

  • @decenasoundworks
    @decenasoundworks Рік тому

    Boss sana masagut mo ..pwd ba baliktad Ang live at ground sa breaker galing sa poste

    • @SAYDETV
      @SAYDETV  Рік тому

      Pwede kahit magkabaliktad basta wag langagkasalubong.

    • @decenasoundworks
      @decenasoundworks Рік тому

      @@SAYDETV thanks bro God bless

  • @eveliasoreno6015
    @eveliasoreno6015 Рік тому

    idol pgawa nman ng schematic nito slmat sana mpansin

  • @airsoftone5893
    @airsoftone5893 Місяць тому +1

    Ganon ba yun? Ang taas pala ng kailangan ko na rating ng Main MCB. 3 AC of 1.5HP, 2 shower heater of 6000W each, 1 oven, 1 range hood, 1 toilet extractor, 1 washing machine, 1 dryer, lightings interior at exterior, etc... may pump pa sa labas.

    • @SAYDETV
      @SAYDETV  Місяць тому

      100A or 150A ang main mo nyan, hindi nman yan sabay sabay ginagamit

  • @RobertValdez-wy6ro
    @RobertValdez-wy6ro 26 днів тому +1

    Sp 60 ampers dapat pra mgibh 44 ampers

  • @jasjamjr1862
    @jasjamjr1862 6 місяців тому

    Sir 30amps ang nilagay ng electrician samin appliances namin dryer,washing rice cooker tv na may tv plus ,5 cellphone na chinacharge tsaka isang speaker at 5 ilaw namin Plantsa pero madalang lang ginagamit,ayos lang po ba un at ang tanong kopa po pwede parin po ba non ang 30amps kung sakaling makabili ako ng ref?sana po.mapansin nio salamat po😊

    • @SAYDETV
      @SAYDETV  5 місяців тому

      Kaya pa yan ng 30A kahit madagdagan pa ng ref, pwe rin lagyan mo ng sariling breaker ang ref 20A.

  • @jhoryldandoy6174
    @jhoryldandoy6174 Рік тому

    Boss kya n b ang 30amp sa 7 ilaw 4 n outlet w/ appliances lalo n yung sa ref

    • @SAYDETV
      @SAYDETV  Рік тому

      Oo kaya na yan malaki pa allowance nyan

  • @fernandobautista7089
    @fernandobautista7089 9 місяців тому

    Sir good am Po ask ko lang kung ano Po Ang sanhi ng pag iinit ng Isang breaker over load Po ba salamat

    • @SAYDETV
      @SAYDETV  9 місяців тому +1

      Oo overload yan piro kung minsan kahit hindi overload basta malapit na masira ang breaker umiinit yan sign na malapit na bumigay.

  • @Jonmix07-zj8qr
    @Jonmix07-zj8qr Рік тому +1

    Sir patulong po, meron ako Single Phase Induction motor 1.5HP Pure Copper 10.4A na ginagamit ko sa pressure washer. Gusto ko sana lagyan ng magnetic switch.ilang amps po dapat na magnetic switch? Thank you and advance sir

    • @SAYDETV
      @SAYDETV  Рік тому +1

      30A ang gamitin mo para sa 1.5hp.

    • @kuyanoltv8516
      @kuyanoltv8516 11 місяців тому

      ​@@SAYDETVkahit 20.lang boss

  • @EricksonDakit
    @EricksonDakit Рік тому

    Boss ilang ilaw naman Ang allowed sa 15 amperes konware tag 100watts?

    • @SAYDETV
      @SAYDETV  Рік тому +1

      27 pcs bulb na tig 100W may video na tayo nyan ito ang link 👇ua-cam.com/video/zPre6juLtpA/v-deo.htmlsi=2IfzVMS6kZIewbpU

  • @mara69323
    @mara69323 8 місяців тому

    32amp X 6
    16amp X 2
    total of 224amp
    144 pag na compute na sir...
    MAIN 63Amp as contractor Installed
    pwede ba syang taasan kasi yung contractor nag install eh..............thanks

    • @SAYDETV
      @SAYDETV  6 місяців тому

      Pwede sir, pwede rin hindi na kasi yong load mo hindi nman yan sabaysabay ginagamit

  • @darwindugan4934
    @darwindugan4934 8 місяців тому +1

    Taga diin k?

    • @SAYDETV
      @SAYDETV  6 місяців тому

      Mindanao

  • @Ruel_Espiritu
    @Ruel_Espiritu 11 місяців тому

    Paano naman idol yung 179.2 na compute sa madaming breaker para sa aircon

    • @SAYDETV
      @SAYDETV  10 місяців тому

      Ang kailangan lang mas mataas ng kunti main breaker sa computation ng load mo.

  • @ariesvaliente3995
    @ariesvaliente3995 Рік тому

    Idol main ko 60a branch 4pc 30a at isang 15a ,, pwede kya un,,

    • @SAYDETV
      @SAYDETV  Рік тому

      Para saan ang 30A dapat 20A lang tapos ang 30A para sa mga mataas ang power lang yan kagaya ng aircon

    • @ariesvaliente3995
      @ariesvaliente3995 Рік тому

      @@SAYDETV bawat kwarto n kc nilagay ko Isang breaker,, Isa kusina kaya 30a n nilagay ko , , ok lng kaya un, ,

    • @BoharyPondiaranao
      @BoharyPondiaranao Рік тому

      Idol 60A ang main breaker ko 4pcs 20A at 2pcs 15A pwede ba yun.sana masagot agad,salamat.

    • @teacherperry8514
      @teacherperry8514 28 днів тому

      ​@@BoharyPondiaranaosabog kapo jan boss i add mo lahat yan 20x4= 80 + 15 + 15 = 110 X .80 = 88 X .80 ulit total= 70.4 ang need mong MAIN Circuit Breaker.
      Ang payo ko sayo hatiin mo nalang yan sa dalawa.
      20 + 20 + 15 = 55x.80 = 44 then multiply again sa .80 = 35.2 so ang need mo na breaker is #40mcb.

  • @BabyAndrei2025
    @BabyAndrei2025 Рік тому

    Sir sayde, Yung nabili po namin is 60 na main 20 sa outlet at 15 ilaw, Papalitan ko po ba yung 60 na main ng 40? Sana po masagot.. salamat!

    • @SAYDETV
      @SAYDETV  Рік тому +1

      Kung kumpleto ka po ng appliances sa bahay mo ay pwedeng wag mo na palitan ang 60A, kung miron ka kahit isa dyan aircon or ref wag mo na palitan ang 60A. kung kunti lang naman ang appliances mo palitan mo ng 40A mataas masyado ang 60A.

    • @BabyAndrei2025
      @BabyAndrei2025 Рік тому

      Salamat po..

  • @masterbrook0358
    @masterbrook0358 10 місяців тому

    Anong size ng main breaker ang pwede sa 4pcs 20A at 1pc 15A diko malaman kung 60A or pwede poba sa 70A nalang? Ano po recommend nyo?
    or if 5pcs na 20A at 1pc 15A nasa total 73.6A by 80% safe poba sa 70A main breaker? ano po recommend nyo?

    • @SAYDETV
      @SAYDETV  10 місяців тому

      60A lang recommended ko masyado naataas ang 70A

    • @masterbrook0358
      @masterbrook0358 10 місяців тому

      @@SAYDETV ket sa 5pcs na 20A at 1pc 15A masyado parin mataas sa 70A?

  • @johnkuyzvlogmotorbikeandsc4523
    @johnkuyzvlogmotorbikeandsc4523 9 місяців тому

    Sir pwd ba yung inverter welding sa outlet na 20amp breaker o hindi pwd..

    • @SAYDETV
      @SAYDETV  9 місяців тому

      Kung portable lang ang welding mo ok lang piro kung malaki hindi

    • @sheryllmelandres-d2c
      @sheryllmelandres-d2c 8 місяців тому

      ​@@SAYDETVboss pano kapag 20 ampere breaker at malaking welding. San po magsasak ngwelding machine kung 20 ampere lng po para sa outlet

  • @JolevieBestudio
    @JolevieBestudio 5 місяців тому +1

    Morning boss ganyan dn gusto ko itanong 30 dn sana ilagay ko Buti na kita ko vlog mo.....ano Po wire gamitin ko sa 40Am galing main supply

    • @SAYDETV
      @SAYDETV  4 місяці тому

      #8 po para sa 40A

  • @medinapareja
    @medinapareja 7 місяців тому

    Dalawa 15 ahmps at apat 20 ahmps po.Ano sa main ampere po?

    • @SAYDETV
      @SAYDETV  7 місяців тому

      60A gamitin mo

  • @MyPinkBlush
    @MyPinkBlush 6 місяців тому

    0.5 hp po ang aircon ko. Ilan amperes na breaker ang gagamitin para sa aircon?

    • @SAYDETV
      @SAYDETV  6 місяців тому

      0.5hp 20A lang na breaker

  • @chrismanggan8955
    @chrismanggan8955 7 місяців тому

    Tanong lang po sir ung cb.electric meter ko 30amp.ngaun po ung panel box ko main breaker nya 40amp.wire no.10 thhn tapos ung branch breaker 30amp.at 20amp.tama ba un sir or mali.slamat po sa sagot

    • @SAYDETV
      @SAYDETV  6 місяців тому

      Pwede na yan piro pwede mo rin palitan ang 40A mo na main ng 30A lang at ang branch mo ay 20A para sa outlet at 15A para sa ilaw.

  • @LuisAlforque
    @LuisAlforque 5 місяців тому +3

    Sir ask q lng.. Pwede qb taasan yun main breaker nmn na.. 60 amp.. Nag overload kc.. Plagi nag trip off yun aircon nmn.. Kapag nakaunplug yun isang ref nmn hnd na nagtitrip yun aircon.. Tanong q lng.. Anong size kaya ang pwede sa main breaker.. Sna masagot po slmt po.

    • @LuisAlforque
      @LuisAlforque 5 місяців тому +1

      Yun panel board q my load na 3x 20 amp saka 2x30 amp. Bkit Kaya nagtrip yun 30amp. Yun main breaker q 60 amp. Nag overload cia.. Ano kaya maganda gawin.. Slmt po s sagot.

    • @SAYDETV
      @SAYDETV  5 місяців тому

      Alin ang nagtitrip lage yong main breaker ba o yong breaker ng aircon? Kung main breaker ay pwede mo yang taasan ng 75A kung breaker ng aircon nman ay palitan mo ng 30A

    • @LuisAlforque
      @LuisAlforque 5 місяців тому

      Yun breaker lng ng aircon ang plagi nagtitrip.. 20cb tpos nakaconnect yun sa,30cb..tpos nkaconnect p yun sa main breaker.. Rcbo ang breaker.. Iniisip bka sobrang sensitive yun kya ngtitrip.. Balak q plitan ng mcb yun kulay itim.. Susubukan q bka hnd n magtrip. month plang yun ac nmn..

  • @darwindugan4934
    @darwindugan4934 8 місяців тому +1

    Pwde b 50A

    • @SAYDETV
      @SAYDETV  6 місяців тому

      Pwede sir depende sa loadp

  • @junmercadojr3587
    @junmercadojr3587 Рік тому

    Sir syde PANO b magdagdag ng ilaw in actual situation...KC nkasemento n ung mga pipe at wala nmang nka install na junction box para sa mga joints.bale direct nko magtap sa linya pero wala power bkit Kya???? Line to line ito..ung dalawang linya galing switch ung isa direk sa ilaw tpos ung kasu od na return sa ilaw nka konek sa Isang live at ung isa pa n linyang ntira sa switch e ikinonek ko sa isa pang live pero bkit wala power????? Tnks...

    • @SAYDETV
      @SAYDETV  Рік тому +1

      Mali ang tapping, saan ka kumuha ng supply? Ito ang sundan mo, ang isang wire ng supply mo idiritso mo agad sa receptacle ng ilaw, tapos ang isa pang wire ng supply mo e-connect mo sa switch sa common tapos ang return ng switch deretso uli sa receptacle.

    • @AlicemejiaCajucom
      @AlicemejiaCajucom 9 місяців тому

      Dalawang 2hp na airco saka tatlong ilaw dalawang elactricfan ilan ampers po dapat na ilagay samain

  • @jay-arsalvador3020
    @jay-arsalvador3020 Рік тому

    4 na freezer ilang amp na dapat sir?

    • @SAYDETV
      @SAYDETV  Рік тому

      apat rin na 30A breaker tig iisa sila.

    • @jay-arsalvador3020
      @jay-arsalvador3020 Рік тому

      @@SAYDETV ilang ang watts po ba ng isang freezer?

    • @SAYDETV
      @SAYDETV  Рік тому

      @@jay-arsalvador3020 depende sa laki, tinggnan mo may makikita yan dyan specification kung ilang watts or ampers. Piro pag sinabing freezer or ref may sariling breaker yan 30A or 20A.

  • @danilodagohoy7801
    @danilodagohoy7801 Рік тому

    Pwede po ba 30amper dalawa?

    • @SAYDETV
      @SAYDETV  Рік тому

      Pag branches na breaker 20A lang sa outlet at 25A sa ilaw gamit ka ng 30A kung air con, freezer or kahit ano na appliances na mataas na ang power

  • @BernandinoAguilar-ng2uj
    @BernandinoAguilar-ng2uj 6 місяців тому

    boss saan k.kumuha ng formula mu.n .80

    • @SAYDETV
      @SAYDETV  6 місяців тому

      Power factor yan, pag nag compute ng load

  • @bethninalucernas4863
    @bethninalucernas4863 2 місяці тому +1

    Bakit di po 30a?

    • @SAYDETV
      @SAYDETV  2 місяці тому

      Pwede sir 30A kung mababa lang ang load mo

  • @Protect-l3e
    @Protect-l3e 9 місяців тому

    Sir ok lang po ba? 21 lahat ang ilaw namin sa bahay ang dalawang ilaw tig 20 watts ang iban tig 3watts at may .5hp aircon, may 1ref, may 1 dispenser, 1 tv, at may isang electric fan na malaki pang sala at dalawang electric fan na maliit..tapos yung main breaker is 100 amper ok lang po ba ito o kailangan namin palitan..dati kasi 60A ang gamit namit pero lagi nag titrip..

    • @Protect-l3e
      @Protect-l3e 9 місяців тому

      May automatic washing machine din pala sir

    • @SAYDETV
      @SAYDETV  9 місяців тому

      Malaki na yang 100A , sana 60A din ipinalit mo kasi nasira na yon kaya laging nagtitrip piro yong load ng bahay nyo kaya lang ng 60A. Ang 100A pwede nman yan kaya lng midyo mataas para sa load ng bahay nyo, ok lang 75A. At kung may idadagdag pa kayo nh appliances hayaan mo yang 100A

  • @JunRivera-gg8xv
    @JunRivera-gg8xv Рік тому

    Sir papano Kong yong main breaker ay 40 amp lang. Papano Kong laging nka trip.

    • @SAYDETV
      @SAYDETV  Рік тому

      Kung dati ay hindi naman nagtitrip at wala kang idinagdag na load at wala naman problem sa wiring tapos panay na ang trip ngayon palitan mo lang ng 40A rin , piro kung may mga idinagdag ka na load palitan mo ng 50A o 60A.

  • @kidoskids2019
    @kidoskids2019 11 місяців тому

    sir ok lng ba may 12 branches ako 100amp main breajer tpos my apat na tig 20amp my 7 na tig 15amp ok lng ba yan sir thnk uu

    • @curi0usminds
      @curi0usminds 10 місяців тому +1

      125A CB

    • @SAYDETV
      @SAYDETV  10 місяців тому

      Pwede yan sir na main 100A kahit nga 60A lang hindi naman sabay sabay ginagamit ang load mo at depende rin yan sa dami ng load mo,.

  • @danielcastelo625
    @danielcastelo625 11 місяців тому

    Boss yung main q 60A tpos ppsok s bhay 40A pra s mnga ilaw computer rice ckr heater At electrcpn tpos 20A pra s ref pro bt ng shoshort p rn yung main ano po kya dhilan

    • @EraydaJoyBronidor-vb8us
      @EraydaJoyBronidor-vb8us 11 місяців тому

      Ganyan din po samin sana masagot

    • @SAYDETV
      @SAYDETV  10 місяців тому

      Ang 60A ay mataas na main na yan, baka may mali sa wiring, paki send po kung ilang ang appliances mo sa bahay, at panel board po ba ang main safety switch nyo?

  • @saskemananaliksik17
    @saskemananaliksik17 Рік тому

    Wat if sir kng meron akong aircon na 1hp at may ref aq.. ang main ko ay 40amp lng kaya po ba pagisahain na lng connection ng ref at aircon mag taas na lng aq ng breaker. Sana masagot po ang aking katanungan salamat po.

    • @SAYDETV
      @SAYDETV  Рік тому

      Wag kna magtaas ng breaker kaya pa yan ng 40A ihiwalay mo na lang ang aircon at ref, piro kong kulang sa breaker pwede narin pag isahin

    • @saskemananaliksik17
      @saskemananaliksik17 Рік тому

      @@SAYDETV 4 branches lng panel ko sir. Kaya ba pag isahin ko na lng un ref at aircon sa 20amp na breaker. ..?

  • @relampagosrahmes5
    @relampagosrahmes5 10 місяців тому

    Magkabit ako ng isang 15A at apat na 20A so ang 60A main breaker puede na?

  • @janaspacio3353
    @janaspacio3353 Рік тому

    Sir bumili po aq MCB 240V~ 6kaic nkalagay, pero ang dumating 415V~ 6kaic. Ang sabi nung seller 220V up to 415V daw po un, tama po ba?

    • @SAYDETV
      @SAYDETV  Рік тому

      Oo tama ok lang, ibig sabihin nyan hanggang 415 volt na supply ay pwede dyan.

    • @raultario8419
      @raultario8419 10 місяців тому

      Gudpm..sir saan galing ung 80%

  • @JudylynPusing
    @JudylynPusing 9 місяців тому

    Hello sir ask klng my nkaki sub meter sa akin deneret sa entrance taos 60 breaker nya ok lng po b yun

    • @SAYDETV
      @SAYDETV  6 місяців тому

      Ok lang po yan

  • @robertcelestial656
    @robertcelestial656 4 місяці тому +3

    Ang labo mo mag calcula boss, ang gulo ng paliwanag mo, saka dapat kalculahin mo din kung wattage ng ilaw e halimbawa mo lng, apat bah or ilan, para ma cumpute ng maayos Kase pag beginners hndi ka tlaga maiintindihan,

  • @rickfer9549
    @rickfer9549 2 місяці тому +1

    Boss 1hp aircon ginabit sa breaker na 30amp ok lang ba yun

    • @SAYDETV
      @SAYDETV  2 місяці тому

      Ok lang sir kahit 20A pwede yan kasi 1hp lang nman na aircon

  • @FernandoCo-h6w
    @FernandoCo-h6w 5 місяців тому +1

    Sir ano po kaya problema kpg kumukurap ung ilaw namin kpg bumubukas kmi ng aircon? 60amp ung main breaker namin.

    • @SAYDETV
      @SAYDETV  4 місяці тому

      😊 kasi ang aircon may compressor, motor yan kaya pag ON mo hihigupin ang power kaya kukurap kunti ang ilaw mo at appliances, ang aircon po dapat nakahiwalay ang supply nyan may sariling breaker at outlet para hindi maapektuhan ang ilaw at mga appliances pag nag automatic ON/OFF ang aircon,

    • @FernandoCo-h6w
      @FernandoCo-h6w 4 місяці тому

      ​@@SAYDETVnka separate naman po sya ng outlet at breaker na 30amp pero kumikurap p din kpg bbuksan kpo. Pwde kb gaeing 100amp ung main breaker ko?

  • @yujinkamote5604
    @yujinkamote5604 Рік тому

    Patulong po sir, May tatlong 1hp ako na aircon meron po syang 30amp breaker tig iisa at isang .5 hp na aircon din ang nailgay ay 30amp din po. Meron din po ako water station na my breaker na 30 amp at jetmatic + ref meron po syang 30amp . Ngayon po ang main breaker ko po ay 60 amp lang kaya po ba yan or ano po ipapalit ko na amp. Or mag add nlang ako ng another 60 amp i jump ko nlang po..
    Salamat po sir sana po mapansin

    • @SAYDETV
      @SAYDETV  Рік тому

      Pagnagtrip ang 60A na main mo palitan mo ng 75A or 100A piro kung hindi hayaan mo na, yong sa mga aircon mo dapat 20A lang yan ang 30A para na yan sa 1.5hp.

  • @rodenreyes6320
    @rodenreyes6320 7 місяців тому

    Pwede kayang mag-series ng 2 main breaker na magkasunod ang size( ex. 40 and 60) kung hindi ka sigurado?

    • @SAYDETV
      @SAYDETV  7 місяців тому

      Gamit ka na lang po ng 40A pag nagtrip hindi kaya, pwede na po yong 60A

  • @dinoolea8862
    @dinoolea8862 Місяць тому +1

    Kng ganyan sir. Useless phlagay mo ng branch

  • @joelbuenaventura6426
    @joelbuenaventura6426 6 місяців тому

    Sir anu maganda sa Main
    *2pcs 1.5 hp Aircon, tv ref ilaw

    • @SAYDETV
      @SAYDETV  6 місяців тому

      100A gamitin mo na main, 30A sa bawat 1.5hp na aircon 20A sa ret 20A sa mga outlet at 15A sa mga ilaw

    • @joelbuenaventura6426
      @joelbuenaventura6426 6 місяців тому

      Sir may fb ka

    • @joelbuenaventura6426
      @joelbuenaventura6426 6 місяців тому

      @@SAYDETV Hindi ko kasi alam kung ilang breaker ang need ko.. ung 1st flr kasi nandun ung Main Breaker .. Nandun ung 20amp 1hp aircon, 15amp ilaw.. at 20amp outlet plano ko ung 20amp outlet diretso ko na sa 2nd flr dahil sa 2nd flr magkakadugtong na ang outlet ng aircon 1hp outlet at ilaw

  • @ChitaMadriaga
    @ChitaMadriaga 7 місяців тому +1

    Tma lhat cnb m Sr kso hnd ako snap ayn s cnsabi m Isa lng akng welder kso spot plnh trip n kaagad Ang GMT k 30amprs n welding machine bkt m cnsabi yn

    • @SAYDETV
      @SAYDETV  7 місяців тому

      Para lang po yan sa house wiring iba na po pag welding machine recommended dyan gamit ka ng transformer,

  • @AG-wt7hc
    @AG-wt7hc 5 місяців тому

    bt ung iba 60Amp na nilalagay.

    • @SAYDETV
      @SAYDETV  5 місяців тому

      Depende po sa laki ng load

  • @yram_prislin
    @yram_prislin 8 місяців тому +1

    Sir sa 60 A ano pong breaker ilagay? Salamat sa sagot sir

    • @SAYDETV
      @SAYDETV  6 місяців тому +1

      60A main
      30A aircon
      20A ref
      20A common outlet
      15A ilaw
      Pwede pa additional

  • @SolarBoyPH
    @SolarBoyPH 10 місяців тому

    Sir pwede po ba main ko 30 amp, tapos 30 amp sa out let at ilaw, iisa lng ksi linya ginawa sa ilaw at outlet ko, tapos aircon 20amp. Pwede na po ba gawing main ang 30amp?

    • @SAYDETV
      @SAYDETV  10 місяців тому

      30A ang main tapos 20A gamitin mo sa ilaw at outlet

    • @SolarBoyPH
      @SolarBoyPH 6 місяців тому

      Ok po, it means pwede po pagsamahin ang breaker ng ilaw at outlet ko. Kahit 20amp lng po? Kakayanin po ba nya ang load ng washing, ilaw, tv, at computer?

    • @SolarBoyPH
      @SolarBoyPH 6 місяців тому

      ​@@SAYDETVbali yang sinasabi ko sir, sa 2nd floor lng po yan ng bahay ko, bali ung outlet ko sa baba at mga ilaw, bali naka rekta lng po sya sa main. Ok lng po ba yun? Or need ko pa magdagdag ng circuit breaker? Kasi ung main ko po is 30amp po.

    • @SolarBoyPH
      @SolarBoyPH 6 місяців тому

      Sana po mapansin new subs nyo po ako thanks​@@SAYDETV

    • @JunFabros-n1z
      @JunFabros-n1z 3 місяці тому

      ​@@SAYDETVsir kong 30amp ang main ok lng po ba magdagdag pa ng 30amp at 20 amp