TOOL CHANGE PARAM

Поділитися
Вставка
  • Опубліковано 9 лис 2024

КОМЕНТАРІ • 6

  • @policebox1092
    @policebox1092 3 роки тому +1

    THANKS FOR SHARING

  • @kevinmikemuriuki
    @kevinmikemuriuki Рік тому

    Great video! Can this be used to resolve a mid tool change problem? A tool got stuck on the spindle while executing M6 command. The swinger arms are attached to both tools while the tool partially out of the spindle. The machine doesn't seem to realise that there is a next (indicates zero) to still attached to the arm and has mixed up both tool number. Apc step resolve doesn't seem to work.

    • @pocketcharleywithgosiger
      @pocketcharleywithgosiger  Рік тому

      This process should solve the issue, as long as the reason behind the interruption is not something electrical. If, for instance, a clamp/unclamp switch fails causing the stoppage, you won't be able to use this cycle as the machine is still dependent on that particular switch to allow forward progress. If the interruption was an emergency stop, then this will also not work, as the machine will be unable to confirm that the X and Z axis are in their G30 P1 location and the spindle will no longer be in orient lock position. These situations require turning on the system check mode and walking the tool arm back, then confirming the registration of tools is corrected

  • @policebox1092
    @policebox1092 3 роки тому

    Sir
    I have a one question
    How use about OSP P200L ?
    OSP P200L have no No tool M6 parameter.

  • @chadwilliams426
    @chadwilliams426 5 років тому

    Was wondering f you could help me figure out how to set and or write a parts counter program for the genos L250e. Thanks