How to Replace a HVAC TXV with Piston

Поділитися
Вставка
  • Опубліковано 28 вер 2024
  • Welcome to HVAC with John Israel UA-cam Channel. On this channel I Bring you along on HVAC Service calls, HVAC Installs, HVAC Maintenance and pretty much anything else HVAC related. Enjoy and thanks for watching.

КОМЕНТАРІ • 236

  • @TedCookHVAC
    @TedCookHVAC 4 роки тому +23

    Sometimes that tiny bit of efficiency sacrificed is well worth it for trouble free operation..... good video John !! Keep them coming.

    • @hugoayala6262
      @hugoayala6262 Рік тому

      Can I do the same with a duel fuel system? Since I’m having trouble to get a hp coil?

  • @Heavy_metal_rulez
    @Heavy_metal_rulez 4 роки тому +35

    I have done the same thing many times before when a txv fails. A piston is a much more simplistic metering device that can literally be trouble free. I wouldn't have changed the drier either. Good job John!

    • @walterdarvin9983
      @walterdarvin9983 2 місяці тому

      Very good job done John

    • @corycross5120
      @corycross5120 Місяць тому

      What about the screen before txv what if that was clogged? Was there not one? I only have 1 1/2 exp. Just asking.

    • @dbh3978
      @dbh3978 Місяць тому +1

      How do you know what piston size use if the manufacturer only references to replace only for another TXV???

  • @frankgonz31
    @frankgonz31 4 роки тому +29

    I wouldn't change the drier ether, it's just an in and out job.and when you have been doing this for awhile you know your stuff.great job .

    • @m0fr3sh90
      @m0fr3sh90 4 роки тому +1

      The txv failing so quick and crappy drainline shows the installer was a hack. Why take a chance with leaving the dryer, 5 minutes to replace.

    • @UltraHydrophobiccoat
      @UltraHydrophobiccoat 4 роки тому

      No, you can have dirty stuff there

    • @bobakleh1397
      @bobakleh1397 3 роки тому +1

      Agreed, if you leave the system open for a while then it can bring in some moisture. Even then, the filter drier will dry it out, and its a brand new drier. Forget that, look at that boogers on the braze. SMH.

    • @rodgraff1782
      @rodgraff1782 Рік тому +1

      From the looks of those braze joints, and burned up grommet at the indoor coil, one has to wonder how good the rest of the workmanship is. Maybe the TXV failed due to scale or contamination in the system. I would definitely change the dryer. Who knows what contaminants are inside that system,if you’re not the one who put it in?

  • @andrewtylerjr2342
    @andrewtylerjr2342 2 роки тому +6

    I say... Great Job! We've bought a new house one and a half years ago. The TXV has to be replace already. I think that the piston system would be a wonderful idea... Thank You for Sharing

  • @bobwhitfield9491
    @bobwhitfield9491 3 роки тому +2

    Thanks for the content bubba John I'm going through school in Vegas and I learn best from watching people do the job. I'm from the south so I can listen to you talk without getting distracted or annoyed! Hell yeah and thank you!

  • @andreeriner811
    @andreeriner811 3 роки тому +4

    I have no issues with replacing a bad txt with a piston I’ve done it a million times. I’m like you though, if it’s a warranty unit I will get a new valve if it’s under warranty. I also agree with you about the filter dryer.

    • @kreep3r
      @kreep3r Рік тому

      There are houses with undersized units that need a piston to produce 32 - 33 degree coil temp

  • @TheLenaweeTrekker
    @TheLenaweeTrekker 4 роки тому +1

    Oh yeah, good hardware gets saved. I have the old Tecumseh compressor covers and a bunch of the overload holding brackets and the new Tecumseh compressor covers. I also save the different capacitor mounting brackets. I have a Graslin defrost timer box filled with the extra parts from those ACME 700 fan motor kits.
    I can't believe how many times those old bits saved my butt in the field.

  • @Austin23191
    @Austin23191 2 роки тому +2

    I agree with you about the filter drier. I replaced a txv on a trane unit today and the drier was built into the condenser. I pumped the condenser down so I wouldn't have to recover the r22 and pulled a real good vacuum. 1 Trublu hose on the suction and bluevac gauge on the liquid. Pulled down to 211 microns in about 20 minutes

  • @waynehensley132
    @waynehensley132 4 роки тому +1

    Nice job John, really enjoyed watching this

  • @rodgraff1782
    @rodgraff1782 Рік тому +3

    I always put the caps on the service valves while pulling a vacuum. Don’t trust the O rings alone.

  • @thisisyourcaptainspeaking2259
    @thisisyourcaptainspeaking2259 3 роки тому

    Thanks for taking us along, good work.

  • @pnajera3938
    @pnajera3938 4 роки тому +15

    Not a problem installing a new filter dryer , thats why they have vacuum pumps.

  • @indyoutdoors812
    @indyoutdoors812 4 роки тому +2

    John, please provide more videos, and get back to the hangouts. Miss ya brother

  • @thecurious6721
    @thecurious6721 Місяць тому

    I like the way you show your work the same way that 99% of the techs do, and dont give a shit of the opinion of 1% youtube police 😂👍

  • @williamjthepoet1675
    @williamjthepoet1675 4 роки тому +6

    Did I not see a nitrogen pressure test?

    • @johnson4940
      @johnson4940 3 роки тому +1

      If you trust your work enough you can skip nitrogen test!

    • @egbertsanchez6264
      @egbertsanchez6264 3 роки тому +1

      He held vacuum before releasing refrigerant. Ultimately if micron reading don’t rise there’s no leak

  • @gmillions1
    @gmillions1 2 місяці тому

    How do you size the piston or are they a fixed size orifice?

  • @MyLeafy1
    @MyLeafy1 3 роки тому +1

    piston came with the airhander optional bag or you cross referenced it? nice work

  • @robertport3620
    @robertport3620 4 місяці тому +1

    A TXV system is far superior of a metering device than a piston. I would never change to a piston. But I have been doing this for 50 years.

  • @PURGE-3000
    @PURGE-3000 3 місяці тому

    What about in cool weather? Won’t the piston over fill with liquid and that might reach the compressor ?

  • @brianbray5397
    @brianbray5397 2 роки тому +1

    Be aware that when you jump power using the equipment ground as a return, everything bonded now has return current on it.
    i have done it myself when there is no alternative, just be aware of what your doing.

  • @dirkcanyow
    @dirkcanyow 4 роки тому +1

    Great video John, thank you for passing along the knowledge.

  • @gerardonavarrogomez7289
    @gerardonavarrogomez7289 4 роки тому +1

    Hi ! Excellent videos thanks 🙏🏻 1 question if I want to work with the home insurance to they send me jobs how can I do that I don’t know if you can answer this but thanks for your videos again

  • @emanuels.6541
    @emanuels.6541 Місяць тому

    How do you know what size piston to install

  • @kennethdandurand3472
    @kennethdandurand3472 3 роки тому

    OK, I am still new to this, so please answer me this. I picked up a Evap coil by ADP. The liquid line attaches to the front of the case...and has a piston in it, but the unit is for r22 or 410a and has a cap on it. At 12:00 on your video you have what I do on the right or bottom side, but I can not find anything to connect to it...i.e 3/8 copper tubing to your left side or top. What kind of connector is that on the left or top side? Under the cap on mine is the white seal, then piston, and then another small white seal. I spent the better part of an hour going to every fitting I could at Lowes...so they do not have it. I recon that the threads are for a TXV valve...so what else has those threads??? This is obviously not a flared or compression connection. The threads appear to be (exact measurements here...) .75 OD of the threads, and the flat is .675 and the threads appear to be 24 Tpi. Help, maybe?

  • @fernandofrancisco3106
    @fernandofrancisco3106 Місяць тому

    Good to know

  • @Demy26
    @Demy26 4 роки тому

    Good job John.

  • @chaunceyturner871
    @chaunceyturner871 3 роки тому +1

    Ok! Keeping it real.

  • @SuperCano1997
    @SuperCano1997 2 роки тому

    How do you choose a piston for each brand? I am starting in the field.

  • @MrsTashaG
    @MrsTashaG 4 роки тому

    Good job, John

  • @treyconner1991
    @treyconner1991 4 роки тому

    Good stuff, John.

  • @richardvisco6370
    @richardvisco6370 3 роки тому +3

    How do you know what size piston to use did you call manufacturer or have a chart

    • @jeffreyjohn2037
      @jeffreyjohn2037 2 роки тому

      Download a chart. 22 and 410a require specific size

  • @dieseldc409
    @dieseldc409 3 роки тому

    What’s the size of the brass cap you installed over the schrader? Same size as the high side cap outside? Thanks

  • @OBASTOS1
    @OBASTOS1 4 роки тому

    Hey body are you and your family okay with the huracán?
    God bless you!

  • @andygalindo8978
    @andygalindo8978 4 роки тому

    Great video

  • @hvactechpr7872
    @hvactechpr7872 4 роки тому

    7/16" open wrench on that equalizer does the trick with a 5/8" open for the nut

  • @proudlysig3934
    @proudlysig3934 4 роки тому +3

    No offense but this is the problem in our industry people still act like it's 1985.. if you install a txv properly like flowing nitrogen when you braze and keep the valve and bulb cool you normally don't have many problems out of them just my 2 cents. Don't get me wrong fixed metering devices are great man but grown with the times txv is the way to go..

    • @eleven8948
      @eleven8948 4 роки тому

      Whats the advantages/disadvantages between the 2?

    • @angelt4186
      @angelt4186 4 роки тому +1

      @@eleven8948 TXV would save you a couple of bucks per month (that's the advantages). However, when they break (and they will break before the compressor gives up) you will spend around $800-$900 to replace it (that's the disadvantage). Choice is yours!

    • @rodgraff1782
      @rodgraff1782 Рік тому

      @@angelt4186 I’ve worked on a lot of systems with TXVs. I never had to replace one, except for the power head. I only worked with Sporlan and Alco valves. Efficiency is not the only advantage of using an expansion valve. They are much better at controlling the refrigerant under adverse conditions, such as a lower than desired ambient. Better refrigerant control equals longer compressor life. I don’t know anything about the reliability of some of these new cheaper valves, probably made in red China. Most of my experience with TXVs were on larger commercial systems. They did not use valves like Danfoss. Pistons are not an option on commercial units. They are mostly TXVs and EEVs. Again, hardly any TXV problems except for the occasional power element. It’s all about the cleanliness and care taken during system installations. It’s odd that all these so called TXV problems are on residential split systems.

  • @wlms04
    @wlms04 4 роки тому

    Glad to see you're back uploading

  • @TheJj787
    @TheJj787 Рік тому +1

    Oh my God, you not replace the filter dryer 😂😂😂😂

  • @paulrozinski1488
    @paulrozinski1488 3 роки тому

    You said that the unit can’t keep up with cooling. The second clue is that it’s a construction company office. I’ll bet that there are people coming in and out all day long and those people were probably outside in the heat all day and looking for some relief. I’ll bet if you run the unit with only 1 or 2 people present, the unit will keep up.
    Wanda u think ???🤔

  • @RichieRich210
    @RichieRich210 4 роки тому

    Have you sent that shirt for judycat boss?

  • @kevinkevin9448
    @kevinkevin9448 4 роки тому +1

    Nice video why would I change it to a piston just wondering

    • @rpsmith
      @rpsmith 3 роки тому

      I have no clue why anyone would prefer a piston over a TXV.

    • @jeffreyjohn2037
      @jeffreyjohn2037 2 роки тому

      @@rpsmith so you are clueless?

    • @armantokimiadi1900
      @armantokimiadi1900 2 роки тому

      @@rpsmith I have some rental properties, 30 to 40-year-old houses. Some have Bryant air handle units those have piston flow raters. I bought those properties back then in 1995 and 1996. One Bryant unit condenser has a Master Valves; metal seal valved is closed after you charged the system. I have never lost any freon in the system the last 12 years. No problem with piston rater for the air handler for 27 years, of course never replace it yet on PSC motor inside the air handler. The other condenser is RUUD. It does not have master valves at the condenser, have to charge the freon every 3 years. Inside unit is Bryant; 27 years old, just replace the PSC motor last year. It costs me $125 and I installed it myself about 3 hours with cleaning up the blower wheel. All using R22 systems. You do not know how expensive is to change the TXV now a day, between $750 to $1000. Lucky, I do not have to have a headache with the txv. Now a day I have to change the compressor on my 8-year-old condenser. Your efficiency of your air conditioning system is determined by how much heat is removed from the inside that depends on how much freon flows in pounds multiplied by latent heat of evaporation of the freon. Other newer house I had to replace X-motor inside the air handler on 3-year-old unit, this pissed me off. It cost me $400 motor only, I installed it myself. Hand down I choose the refrigeration system using master valves at the condenser, sight glass, piston rater; psc motor at the air handles. If your suction line by your condenser is at 40 to 45 degrees that is the best to cool your compressor, your compressor will last very very long. Compressor for the Bryant unit was piston compressor that still working like a champ (27 years since I bought the house). The compressor for Ruud was Rotary compressor made by Copeland) 27-year span is a long time to see who perform best. Regards, Armanto. Mechanical Engineer

  • @mnew213
    @mnew213 4 роки тому

    How much you charge for this service?

  • @joelmelendez5916
    @joelmelendez5916 4 роки тому

    The txv was faulty ???

  • @tonygarcia1743
    @tonygarcia1743 3 місяці тому

    👍👍👍👍

  • @dexenationgracey1979
    @dexenationgracey1979 2 роки тому

    Is a TXV even that much more efficient than a piston? Seems like they're not worth the hassle.

    • @Austin23191
      @Austin23191 2 роки тому +1

      They are a tiny bit more efficient but they aren't worth the hassle. You get 1 maybe 2 extra seer on single stage equipment by using a txv but a much bigger headache when it fails. I should ask Rheem what size piston my coil needs when the txv finally goes bad

  • @mr.18s73
    @mr.18s73 4 роки тому

    What about a carrier coil.....not the sam3

  • @marchomeautorepairs
    @marchomeautorepairs 3 роки тому

    Keep up the good work

  • @jimtalor7971
    @jimtalor7971 4 роки тому

    Let me say something!! You Da Man!!

  • @frankgonz31
    @frankgonz31 4 роки тому +7

    it's a pain when it's in attic.

  • @97Napkins
    @97Napkins 4 роки тому

    I get the feeling system had air in it but whatever. lol Thats why you shouldnt install DU-Crap or any other off brand units. Stick with Trane or Carrier. Been installing Carrier for 6 years now and no bad txvs or leaking coils or dead compressors. have 100s of units in the field. Better belive goodmans would have problems like those by now. I dont need those problems in my life.

  • @twosawyers
    @twosawyers 4 роки тому

    I thought the TXVs were adjustable?

  • @crazydan2327
    @crazydan2327 2 роки тому

    It's the same cabinet as a 5 ton

  • @johngnass27
    @johngnass27 3 роки тому

    De minimus

  • @ricardogalvan7064
    @ricardogalvan7064 3 місяці тому

    Can't see nothing

  • @Quentyn73
    @Quentyn73 4 роки тому +4

    Couldn't you just insulate the bulb? That would've brought things back in line. It looked totally not insulated, it's normal to restrict when it's exposed

    • @joelsadowsky3436
      @joelsadowsky3436 4 роки тому +3

      If the sensor bulb is not insulated or loose it would flood the evaporator and not restrict

    • @abnergarcia6252
      @abnergarcia6252 4 роки тому

      Do you have to insulated even though is inside the evaporator coil housing????

    • @jasonreitz6049
      @jasonreitz6049 4 роки тому

      Exactly, if the bulb is not insulated it will think superheat is too high so the TXV will open more to try to lower the superheat to specs

  • @Akronkangaroo
    @Akronkangaroo 3 місяці тому

    Not really understanding why someone would do this. Seems like you made more work for yourself

  • @stevenbennett9785
    @stevenbennett9785 4 роки тому

    Aluminum condenser but copper evap! I hate Lennox equipment. Dave is behind times!

  • @alejandroalba4758
    @alejandroalba4758 4 роки тому

    I think is better way to say that you don't give a shit about what we think, just saying

  • @dcmarvelunited5529
    @dcmarvelunited5529 4 роки тому +2

    Couldn't you just have adjusted the txv for proper superheat instead of replacing it?

    • @johnisraelhvac2019
      @johnisraelhvac2019  4 роки тому +2

      The valve wasn’t adjustable

    • @dcmarvelunited5529
      @dcmarvelunited5529 4 роки тому

      Aw ok so pretty much the txv went bad. Do you know how long ago the unit was installed before you were called to it?

    • @frankgonz31
      @frankgonz31 4 роки тому

      actually if you remove it from the suction line it'll tell you what's wrong , sometimes.

    • @twosawyers
      @twosawyers 4 роки тому

      I thought all TXVs were adjustable?

    • @dcmarvelunited5529
      @dcmarvelunited5529 4 роки тому

      @@twosawyers thats what i thought.

  • @jeffdavis5700
    @jeffdavis5700 4 роки тому +6

    What size piston did you use?

  • @rogerghiardi7723
    @rogerghiardi7723 3 роки тому +3

    Makes no sense to go to piston, system was designed for a TXV, its also probably under warranty being a brand new unit. Also new filter dryer.

  • @thejnelson88
    @thejnelson88 4 роки тому +7

    Wow, how to drop efficiency and kill the warranty at the same time...

    • @johnisraelhvac2019
      @johnisraelhvac2019  4 роки тому +2

      😂😂😂

    • @thejnelson88
      @thejnelson88 4 роки тому +8

      Hmm let's see your qualifications are you make videos on UA-cam working on residential systems with from one video shows that you lack the knowledge and expertise to perform repairs correctly.
      My qualifications are working on ammonia and synthetic refrigerant refrigeration systems that have miles of piping and complex control systems. What you did in this video is kill the efficiency of the unit and modify it outside of its design by the manufacturer. All in the name of making it easier for you to work on because you lack the common understanding of a txv system. Your probably could have used a manufacturer approved oil treatment to the issue. Even then replacing the txv is not that complicated and time consuming. Given the lack skill with brazing on the install it's safe to presume the installer did not flow nitrogen. With POE oil being hydroscopic its best to install a new filter drier after open a system for repair that's cheap insurance. You can laugh or you can grow with times thought txvs have been around longer than I have been alive so I don't think that's your problem.

    • @johnisraelhvac2019
      @johnisraelhvac2019  4 роки тому +6

      👏🏻👏🏻

    • @vandammewannabe4086
      @vandammewannabe4086 4 роки тому

      @@johnisraelhvac2019 😂😂😂😂

    • @zaidzaw6777
      @zaidzaw6777 4 роки тому

      It was just need few pounds of juice..

  • @Mwfrizzellandsons
    @Mwfrizzellandsons 2 роки тому +4

    I’m not an HVAC man. I just like to know how things work. Excellent video. Thanks.

  • @PB-et9my
    @PB-et9my 10 місяців тому +2

    I appreciate the logical yet professional approach to solving the problem. That's what most of us do that just want to get the job done, take of the customer and no go back a 100 times!
    You can solve a problem or service it over and over...

  • @bobrylander2132
    @bobrylander2132 2 місяці тому +1

    John,.. do your thing, and how you want to do it. Forget all the a-holes who always have negative complaints on what you should and should not do. Wish you could install my new HVAC system. Keep up the good work! 👍

  • @armandorodriguez6447
    @armandorodriguez6447 8 годин тому

    My 3 ton Trane is 26 smh and just went with a piston. No room for txv,tight closet and and 80% flue pipe + bi pass round duct share space. Bro good video

  • @waynespringer501
    @waynespringer501 3 роки тому +2

    The filter drier should have been moved inside, therefore you should have replaced it along with not robbing them by removing a txv for a piston. You should rename your channel to Shade Tree HVAC

    • @joesours6751
      @joesours6751 3 роки тому

      TXV sucks may be energy efficient but not cost efficient when built like crap and you have to pay to change out. Also this is some trash unit from r e micheal that you can tell was not purged bc of the burn mark up the door fuck a TXV and a filter dryer get in get out it’s trashed anyway from the start

  • @paulshlasko3608
    @paulshlasko3608 Рік тому +1

    If the txv goes bad, doesn't the quality of the coolant become suspect? So putting in a new dryer would make sense unless you were in a hurry or something?

  • @wilzv4382
    @wilzv4382 4 роки тому +2

    Been enjoying your videos. I'd like to see a complete step by step on a condenser change out. I know it would be hard to film, but I'm curious of the process and I cant seem to find any videos on it. Either way though great videos. Keep em comin!

  • @tmmyjay
    @tmmyjay 5 місяців тому

    Excellent video! Are the pistons based on tonnage? If anyone has a part number for a piston that works on a 4 ton (York-XAHC48FXXN1A coil) heat pump, please let me know. It ships without a TXV and I'm having a ridiculously hard time sourcing the correct one.

  • @christopherhaak9824
    @christopherhaak9824 Місяць тому

    A TXV should be installed with Staybrite 8. With a good install and vacuum, the TXV is a very robust metering device. Looks like a hack install from the get go.

  • @dbh3978
    @dbh3978 Місяць тому

    How do you know what piston size use if the manufacturer only references to replace only for another TXV???

  • @hvac01453
    @hvac01453 4 роки тому +1

    Good job. The only critique I would add is, you skipped a step... namely pressurizing the system for leaks, to check your work. We’re not perfect and sometimes things don’t close up the way we would like them to. even if it’s only 40 psi ( because of the pump down ) and some bubbles. This way, if the service valve leaked, it still couldn’t leak into the refrigerant side because of the higher pressure.

  • @txhvacr1978
    @txhvacr1978 4 роки тому +1

    Ever think why the txv went bad, a piston may have less parts but it cant control the heat load, how about doing a proper evacuation and install a txv properly, and if there are noncondensables in the system or coming from the dryer, now the piston will be blocked

  • @andreeriner811
    @andreeriner811 3 роки тому +1

    Some of these hacks that install these units know they have no intentions of ever going back to work on them. I go behind people like that to, it’s pitiful

  • @pelon542
    @pelon542 4 роки тому +2

    that loose low voltage wire would've driven me nuts lol

    • @jeffreyjohn2037
      @jeffreyjohn2037 2 роки тому

      Shows the hackery of the original installer.

  • @kanive1566
    @kanive1566 Місяць тому

    Does it matter which brand piston you use or are most of them interchangeable with TXV's?

  • @HappyLife-vh2ey
    @HappyLife-vh2ey 11 місяців тому

    SO I'm 69 years old just had major surgery .
    I had no ac tech came in went in the ac closet n said the txv failed and put in a piston . He's an old timer and said it will solve the problem and system will run for a long time without issues. Hopefully this is ok he charged me 1k and added 410. Will this affect other components in a negative way. Oh yes unit is 2 years old . I ty all for any opinions. GOD BLESS ..

  • @Parabellum-X
    @Parabellum-X Рік тому

    OH MY GOD! AT 5:59, YOU PUT YOUR YELLOW HOSE ON THE GROUND WHERE DIRT IS GOING TO STICK TO THE OIL AT THE END CONNECTION! AND YOU'RE A HACK FOR NOT CHANGING OUT THE FILTER/DRIER! 😱
    😆 LMAO! Im just messin wit you!!!
    I'm actually surprised no one said anything about the hose-on-the-ground thing! (You know, those nit-pickin turds who hug trees and stuff.) 😆
    You said the system was brand new; there's no need to change out the drier; you're only changing out the metering device.
    Good video, bro; keep 'em comin!
    ua-cam.com/users/sgaming/emoji/7ff574f2/emoji_u1f631.pngua-cam.com/users/sgaming/emoji/7ff574f2/emoji_u1f631.png

  • @ThermalDynamicSevices
    @ThermalDynamicSevices 4 роки тому +8

    The guy who installed that condenser sure did leave some ugly solder joints lol I wouldn’t change the drier either, keep up the good work John!

  • @zaidzaw6777
    @zaidzaw6777 4 роки тому +1

    It was just need few pounds of juice..

  • @darrenaugustine6508
    @darrenaugustine6508 2 роки тому +1

    What size piston do you use? Do you have a chart for different tonnages?

  • @rogergregory6512
    @rogergregory6512 4 роки тому +1

    Man I hadn't seen anything from you in awhile I didn't know if you were still alive. Glad you are.....

  • @michaelwright4095
    @michaelwright4095 2 місяці тому

    How did you determine what size piston to use?

  • @RW-to2fy
    @RW-to2fy 8 місяців тому

    Need to adjust the camera angle in order to see the work area

  • @walterrifle2725
    @walterrifle2725 5 місяців тому

    Ted Cook wouldn’t have done it this way

  • @picklerix6162
    @picklerix6162 4 роки тому +1

    The closet that my furnace and 5 ton coil is located is a little bit wider but shorter than the one in this video. Removing the old HVAC equipment out wasn't that bad but installing the new equipment was a pain in the rear. I had to get a winch and pulley to drop down the old coil from the attic (after removing the furnace) and pull up the new coil. My daughter helped me remove the old furnace (after I removed the blower assembly) and she also helped me lift the new furnace into place. I dropped the new coil down onto the new furnace after I put a thick bead of silicone on top of the furnace to seal it. I attached and sealed the new plenum to the top of the new coil. I think I lost ten pounds just installing the furnace and coil. BTW, I pre-piped the coil (so the pipe would be easily accessible for final soldering with Stay-Brite 8) and pressure tested the coil and pipe before soldering it to the line set. I have no idea how the installer got the original furnace, coil, and plenum installed in my house when it was built. Somebody said that it was probably installed before the sheetrock went in and that makes sense.

    • @greyguy9767
      @greyguy9767 2 роки тому +1

      Not necessary to caulk the coil box. The amount of air loss is a minute factor on a proper fitting coil. May never come out again.

  • @tonydelgrego2906
    @tonydelgrego2906 4 роки тому +1

    As always another great job and a new customer.
    Stay safe my friend

  • @jorgeLopez-xn9uy
    @jorgeLopez-xn9uy 4 роки тому +1

    Thank you so much. This video is really helpful..

  • @steveg5576
    @steveg5576 4 роки тому +1

    You got stickers now ????

  • @serenity6988
    @serenity6988 2 роки тому +1

    a real hvac tech!! Thank You...

  • @larryh2161
    @larryh2161 3 роки тому +1

    how about pressurizing with nitrogen before the vacuum?

  • @jsparlin1
    @jsparlin1 Рік тому

    what size piston?

  • @prettycureforever7102
    @prettycureforever7102 4 роки тому +1

    Couldn't you have just put a new power head in that bby see if it works

    • @jonsaircond8520
      @jonsaircond8520 4 роки тому

      Power heads for residential valves aren't removable

  • @ajgonzalez9926
    @ajgonzalez9926 2 роки тому

    What

  • @basspig
    @basspig Рік тому

    I don't quite understand why you're measuring superheat when you have a txv. Supposedly superheat varies with the operation of a TXV. Or so a technician at Mr Cool told me.

  • @Aj-hi2kc
    @Aj-hi2kc 4 роки тому +1

    Evening John, while I understand location makes all the difference; what do you typically charge to replace HVAC TXV? Local companies are quoting between $1800 and $2000. Thanks in advance.

    • @ljv2094
      @ljv2094 3 роки тому

      That's how much we charge in the bay area

    • @brettr5188
      @brettr5188 Рік тому +3

      That’s insane. A txv is about 100 dollars. 2 hours of labor. No way it should be over a 500 dollar job unless u lost all your refrigerant.

    • @infl
      @infl Рік тому

      @@brettr5188Man they’ll charge you $1000 for a capacitor…

  • @booch32484
    @booch32484 4 роки тому +1

    Nice wrist burn bro

    • @tomwalker9184
      @tomwalker9184 4 роки тому

      That's a tattoo they call the burner

  • @chinowong69
    @chinowong69 Рік тому

    What piston size did you use ? I believe you said it's a 3ton 410a. Right?

  • @Howyoudoing98765
    @Howyoudoing98765 4 роки тому +1

    No disrespect. All in fun keep up the great work and the videos.