Connect LOGO! with Siemens HMI Panel in Tia PortaL || Ethernet

Поділитися
Вставка
  • Опубліковано 31 лип 2024
  • Lets try and hit 100 LIKES!!
    LIKE & SUBSCRIBE || OPEN THE DESCRIPTION ▼▼▼▼▼
    SUBSCRIBE For more Tutorials and Free Softwares
    ▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼
    This is a New Tutorial on How To to connect SIEMENS LOGO!8.FS4 with SIEMENS HMI Panel ( KTP 400 ) through Ethernet, using LOGO! Soft Comfort v8.2 & WinCC Advanced in Tia Portal 15.1.
    You can Donwload LOGO! Soft Comfort v8.2 through this video :
    • Video
    You can Download Tia Portal v16 through this Video :
    • Video
    Like & Subscribe and never miss any of the Next tutorials about Automation and LOGO! PLCs.
    ____ Summary _____
    00:00 Intro
    00:28 : Create the Program for the KTP 400
    06:22 : Create the Program for LOG! SOFT
    10:24 : Test through Digital Inputs
    10:43 : Test through Mementos
    #SIEMENS #LOGO! #TiaPortaL
  • Наука та технологія

КОМЕНТАРІ • 20

  • @brunovinyl
    @brunovinyl 2 роки тому

    Thanks ! Made it very clear to me .

    • @PROTUTO89
      @PROTUTO89  2 роки тому

      Thank you for Your feedback :)

  • @SpottedEagleOwls
    @SpottedEagleOwls 3 роки тому +1

    Thank you Sir for this. Do you have a video how to use analog values for inputs and outputs

  • @draganmihai4897
    @draganmihai4897 Рік тому

    Thanks very much !

  • @mohammedzayed6914
    @mohammedzayed6914 2 роки тому

    thanks , it become clear and easy >>>

    • @PROTUTO89
      @PROTUTO89  2 роки тому +1

      Thanks so much for your Feedback !

  • @MrTeamDecibel
    @MrTeamDecibel 2 роки тому +1

    Hey I followed your tutorial but when I press one of the HMI buttons I get an error: value could not be written to plc. Any idea how to fix this?

  • @aleemsafdar2120
    @aleemsafdar2120 2 роки тому

    Hi, Nice video you set Logo to Master in M/S Setting. But if we controlling PLC from HMI our PLC should be slave..??

  • @joeltshiela4605
    @joeltshiela4605 Рік тому

    Hello and thank you for the video. Is it possible to change views (go from one view to another) in the case of this video? . If yes, can you please show us

  • @furkansaygin5388
    @furkansaygin5388 3 роки тому

    çok iyi faydalı

    • @PROTUTO89
      @PROTUTO89  3 роки тому

      Thank you for your Feedback !

  • @komar2288
    @komar2288 2 роки тому

    how to change time to real in hmi? using only logo

  • @redcaae
    @redcaae 8 місяців тому

    Seria posible conectar un Logo! con un hmi dop de Delta?

  • @wilsonocasmantilla6987
    @wilsonocasmantilla6987 2 роки тому +1

    Great video. Is it posibble to read and write timers from KTP400?

  • @karoliczanwojtylanu
    @karoliczanwojtylanu 3 роки тому

    Nice video, thanks! Is it possible to programm LOGO in TIA Portal oder LOGO Soft Comfort is necessary?

    • @vinayaksisl
      @vinayaksisl 3 роки тому

      LOGO cannot be programmed in TIA Portal, it will need Logo Soft Comfort software seperately.

  • @velcerindustries4008
    @velcerindustries4008 2 роки тому

    Did you know how to fix this problem?: ***The 'Tahoma' font is not installed***

  • @kinghenry4612
    @kinghenry4612 20 годин тому

    Great video but the teaching demonstration is too fast for learners

  • @vioreltarba4269
    @vioreltarba4269 2 роки тому

    Vreau an limba română