Thank you for this video. These drives have a very confusing menu structure. Most of the functionality in these things I don't even use. I've been tearing my hair out at work trying to get this to work, as described in this video. Re. another video, you mention changing running modes alters some settings, so no wonder why I messed up a drive that was already working... Videos like this are very helpful in understanding the book. Now that I've watched this, I go back and read the menu settings in the book, and I just want to plant my face in my hands, as I feel so stupid that I didn't get it from reading it...
Thank you for your message Saif. We house most of our documentation in a virtual database here: www.se.com/ww/en/download/. If this does not address your concerns, please reach out to a technical support person in your location.www.se.com/ww/en/work/support/country-selector/contact-us.jsp
hello i have a problem with my VFD is showing Over speed i using in Hydraulic pump do you know What parameter can I change to avoid that issue. is ATV630C16n4
Thank you for your message. We house most of our documentation in a virtual database here: www.se.com/ww/en/download/. If this does not address your concerns, please reach out to a technical support person in your location.www.se.com/ww/en/work/support/country-selector/contact-us.jsp
I have problem we have a machine Use two inverter and controled in one volume .. when it damage i change the other one but when i start up the two inverter is more than 10hz defference i need only 2 hz defferent each other ...and now how to set this parameter
Hi Rudy, Thanks for reaching out. Please contact our support team directly for further assistance. Phone: 800-468-5342 option 1 (Internally dial 25777) Hours of operation: 8am-8pm ET, Mon-Fri excluding holidays e-mail: customer.services@us.schneider-electric.com
Remote mode means the speed (frequency or motor speed in Hertz) and command (start and stop control) come from a source outside of the drive (such as a computer or building control center). Local mode means the speed and command are performed using the buttons on the drive itself. These controls can be separate so the command to start can be done locally using the buttons on the drive and the speed can come from a computer (or vice versa).
Hi, thanks for the video, I have gone through all of these commands but still when I run the speed is locked in at 15 and cannot be altered by the dial... is there a limit that’s in place that I can turn off? Please advise
^^This - I wrongly assumed that I could configure the same way as an ATV61/71, by simply going to CTL, access level to 3 (from reading the 312 manual), I/O mode to separate and then ref to the jog wheel with command on the terminal. It didn't work, found this video which helped, but why does the VSD need to be put into local mode in the first place? If you configure the separate I/O mode, command on terminal speed ref on jog wheel, why doesn't it run? Stupid
Thanks for reaching out. The ATV312 is much different than the 61 or 71 as it relates to HMI control. The ATV312 knobs primary function in menu navigation. Speed reference is secondary. The knob can be used as speed control by setting FR1 to AIV1, but to use the knob you must navigate to LFR parameter first (easily done by pressing knob 3 times) The display is shown as 0-100% only, not in Hz this way. In local mode, the knob is primarily speed control, and secondary menu navigation. The way the 312 was engineered, to use the knob for speed control without going to the LFR parameter, we have to put the drive into local mode (knob now works without going to LFR) and set the profile to separate and command via terminals. Hope this helps.
Schneider Electric Altivar -Трехпроводное управление Three-wire control-button ua-cam.com/video/D8ZfJ-XtkHU/v-deo.html
Dmltry Radchenko atv320d15n4bkw20hp380to500vlt
Very nice teaching sir 👍
Thank you very much for your feedback!
Thank you for this video. These drives have a very confusing menu structure. Most of the functionality in these things I don't even use. I've been tearing my hair out at work trying to get this to work, as described in this video. Re. another video, you mention changing running modes alters some settings, so no wonder why I messed up a drive that was already working... Videos like this are very helpful in understanding the book. Now that I've watched this, I go back and read the menu settings in the book, and I just want to plant my face in my hands, as I feel so stupid that I didn't get it from reading it...
U saved my life today.. This inverter really really hard to use.. The programming structure really really really hard to understand..
thank you for sharing this video..good job
Did you just connect the 24v, li1 and li2 + the powersupply for this?
How can we operate the motor in reverse direction using the keypad of this drive?
Thank you for your message Saif. We house most of our documentation in a virtual database here: www.se.com/ww/en/download/. If this does not address your concerns, please reach out to a technical support person in your location.www.se.com/ww/en/work/support/country-selector/contact-us.jsp
Hi,
Once we done this do we need to change rEF parameter to AIUI for the jog enabling? or will it automatically set?
Thank you, you saved my day!!!!
Problems in inverter keypad atv12h075m2 not functioning and out cff code.What should i do?
hello i have a problem with my VFD is showing Over speed i using in Hydraulic pump do you know What parameter can I change to avoid that issue. is ATV630C16n4
Thank you for your message. We house most of our documentation in a virtual database here: www.se.com/ww/en/download/. If this does not address your concerns, please reach out to a technical support person in your location.www.se.com/ww/en/work/support/country-selector/contact-us.jsp
i want ur help...how to connect digital speed meter to avt312 drive? and any parameter setting to digital speed meter....plzhelp me
je voudrai savoir en detail la connection du bornier electronique d un variateur movitrac(x10)
Please Sir solution for OPF1 foalt Atv12hu15m2 vfd
only fowerd run motor no rerwes run motor drive contection p24 F Forwed R rewes but no reweses motor run plz help me
my ATV312 doesn't show rdy in first time i press and i hold the mode key and after rEF displays help me thank you.
How to activate relay function. How to use 0 frequency use normally No 0.1Hz Normally Nc How to activate. Pls send program settings.
Thanks man!!!
All can u help me how to set parameter setting two units of inverter control in one volume
I have problem we have a machine
Use two inverter and controled in one volume .. when it damage i change the other one but when i start up the two inverter is more than 10hz defference i need only 2 hz defferent each other
...and now how to set this parameter
Please help me
Hi Rudy,
Thanks for reaching out. Please contact our support team directly for further assistance.
Phone: 800-468-5342 option 1 (Internally dial 25777)
Hours of operation: 8am-8pm ET, Mon-Fri excluding holidays
e-mail: customer.services@us.schneider-electric.com
Opf1 foalt solution please sir Atv12hu15m2
I dont understand for vfd controll by remote mode
plz tell me about this from starting
Remote mode means the speed (frequency or motor speed in Hertz) and command (start and stop control) come from a source outside of the drive (such as a computer or building control center). Local mode means the speed and command are performed using the buttons on the drive itself. These controls can be separate so the command to start can be done locally using the buttons on the drive and the speed can come from a computer (or vice versa).
Как настроить реверс
How to use DC break Schneider altiva312 ac drive
Input voltage 230volt
Out put voltage 220 3phase
Motor kW 0.75kw
Hi, thanks for the video, I have gone through all of these commands but still when I run the speed is locked in at 15 and cannot be altered by the dial... is there a limit that’s in place that I can turn off? Please advise
thanks
Great
why keep changing ,procedures .in Schneider products , please keep it uniform and make it user friendly .
^^This - I wrongly assumed that I could configure the same way as an ATV61/71, by simply going to CTL, access level to 3 (from reading the 312 manual), I/O mode to separate and then ref to the jog wheel with command on the terminal. It didn't work, found this video which helped, but why does the VSD need to be put into local mode in the first place? If you configure the separate I/O mode, command on terminal speed ref on jog wheel, why doesn't it run? Stupid
Thanks for reaching out. The ATV312 is much different than the 61 or 71 as it relates to HMI control. The ATV312 knobs primary function in menu navigation. Speed reference is secondary. The knob can be used as speed control by setting FR1 to AIV1, but to use the knob you must navigate to LFR parameter first (easily done by pressing knob 3 times) The display is shown as 0-100% only, not in Hz this way. In local mode, the knob is primarily speed control, and secondary menu navigation. The way the 312 was engineered, to use the knob for speed control without going to the LFR parameter, we have to put the drive into local mode (knob now works without going to LFR) and set the profile to separate and command via terminals. Hope this helps.
Sir my v fd derrik not work in load
OSF come, so, that one resetting program tell him
Plz Hindi vedio language to knowledge
Schneider Electric Altivar -Трехпроводное управление Three-wire control-button ua-cam.com/video/D8ZfJ-XtkHU/v-deo.html