How to Check For Bad Compressor

Поділитися
Вставка
  • Опубліковано 19 лис 2024

КОМЕНТАРІ • 11

  • @edwardeliyahhamner4340
    @edwardeliyahhamner4340 3 роки тому

    I love how simple you made this test

  • @realestateinfonet9041
    @realestateinfonet9041 3 роки тому

    Awesome information! Thanks for taking the time to share it with us! Sincere regards!

  • @martinjuarez333
    @martinjuarez333 5 років тому +1

    Thank you so much man you are awesome I learn something NEW in this video thanks for taking your time to make this videos and help a lot of people like me,God bless you

  • @leeleviner8159
    @leeleviner8159 5 років тому +1

    thanks for taking time to do these.

  • @jamesrooney7689
    @jamesrooney7689 5 років тому +1

    great video well explained thank you

  • @jesuschavero7307
    @jesuschavero7307 5 років тому +1

    I liked your video very well explain. ...thanks keep up those videos 👍👍

  • @bhultsable
    @bhultsable 5 років тому

    Appreciate your vid. Quite simple and helpful trouble shoot strategy. What if your numbers on the compressor connections don't add up? I tested mine and the numbers should read 4.9 but instead only get a 4.0 total of the two resistance readings. Is this something that indicates why the compressor will not start? Thanks for any feedback...

  • @steven-sl7jv
    @steven-sl7jv 4 роки тому +1

    All this is done on the same setting on the amp meter?

  • @IvanHVAC
    @IvanHVAC 5 років тому

    Was the compressor bad?

  • @ibbriley399
    @ibbriley399 2 роки тому

    Actually, you are measuring continuity from the compressor lead to paint on the surface of the equipment. You have no idea what the resistance to ground is.