- This video is on how to make connections of relay and make complete board, relay gives maximum saving and maximum safety to inverter, in this video you can learn how to make complete setup board of change over relay , relay can save your more money,
...............................................................,.........,
Follow my Facebook Page Talagang Online
/ talagang.onlline
-----------------------------------------------------------------------------------------------------..
HOW YOUR PERSONAL DATA SHARE ON SOCIAL MEDIA | HOW TO AVOID HACKING OF PERSONAL DATA | MUST WATCH
• HOW YOUR PERSONAL DATA...
------------------------------------
Subscribe my Channel
Like, Comments and Share the Video - Наука та технологія
ماشاءاللہ بہت ہی زبردست ہے
Masha Allah good informative video
ماشااللہ زبردست
Nice information
Nice information sir
Gud wrk sir
Mashala bilal bahi
Mashallah
It is a very good system
The problem is torque load, when their is power failure direct Wapda is off secondary source takes effect. In this process if the load is 800 watts for less than 30 sec the load climbs to 2400 watt
If load increases for example and light goes torque load can shut off your batteries (depending on the Ah of the battery)
I just reduce load and restart inverter
But other than this it is the best
Thanks for sharing experience
Assalam u Alykum
Billal Bie
Mayra gher ki wireing 4 feet ooper yani low load(fan led blub) par 3-29 ki wire use howe ha
Orr
Same 3-29 neecha 4 feet power plug pa b use howe ha joka teek nahi heavy load sa inverter trip hoga
Inverter with Home main line wireing ma Inverter orr Main line ka Nutral wire ko COMBINE ker ka inverter ka liya single phase ko poora gher alydha sa spread karon thu ya teel raha ga?
Sir yeh kam tu aik simple change over double pole breaker bee kr sakta hu kaya??
To yeh b simple change over he h ,
Assalam o alikum bhai
Humain relay laganay ki zroorat kun pash atti hai? Kun k wapda anay ki soorat ma inverter wapda ko bypass kr raha hota hai aur light janay ki soorat ma battaries py shift ho jata hai mean's k relay to is inverter k andar hi mojood hai...
Sir its for maximum saving, but its upto you, relay is not necessary
Inverex aerox 2.2 kW k sath konse panels and kitne panels lagana behter ha. Your suggestion?
Sir better to use inverex,fronus , Risen 330 ,360 watts 5 Panels
Sir mere pass inverex 2.2kw aerox hai 415WX4 panal hain kia 1 or add ker skta hon sie reply zaror kerna
Sir same question replied
Sir panels series mai lagay hain ya parellel mai detail plz???
Sir all panels are in parallel
Salam Walekum Rahmatullah and Barakat Sir, I want to know that I have three fans in my house and the balance is ready, so how much fat should I put on this maximum and which one would be better for inverter In which a CPU also runs and LED also runs If you give me a little guideline then it would be better for me And which plate should I use and which animal is John John? Which company is he right?
Sir not get your point, please contact me on WhatsApp please
Sir aerox 2.2kw sbu setting pe wapda mood pe charging nahi kar raha koi solution bataye
Contact on my WhatsApp no, 03216557487 , WhatsApp only please
You are already using a breaker between Load and Wapda / Inverter why need a relay to switch between Wapda and Inverter, if you switch off the breaker Wapda supply to inverter will be off anyway and Inverter will not take any current from Wapda it will use battery and solar only. I think only if your breaker does not support enough current then it make sense to use Relay
Sir relay is used for maximum saving , if your utility off during day time ok it make sense that inverter will work with pv and battries, but after evening or at 10 pm when you swith on utility all the utility liad will go through from inverter and full night your inverter will run your load from utility and charging battries, but in this relay when you swith on utility no load will be run and no need to charge battries from solar , as battries charge with 500+ Watts, so what you save at da6 time will consume at night
@@solar-wala-bhai2903 Bilal bhai your videos are very good I enjoy them keep it up. thanks for sharing your experience
اسلام وعلیکم
بلال بھائی آپ نے بہت مفید ویڈیو بنائی ہے اس سے واقعی انورٹر رات میں بائی پاس ہو جائے گا اور غیر ضروری لوڈ سے بچ جائے گا لیکن واپڈا بند ہونے کی صورت میں آپ کو بیک اپ بھی ملے گا۔
لیکن اس ویڈیو میں کافی وائرنگ انوالو ہے اس لیے سمجھانے کے لئے اگر وائرنگ ڈایاگرام بنا کر اس کی پکچر دکھا دی جائے تو اسے سمجھنے میں آسانی ہو گی۔
شکریہ
Sir 2 din tak Complete video upload krni h apney system ke kion k iss ko kafi upgrade kia h
Kon si type ki relay h sir
Isko generator relay b boltey hn, changeover relay
AoA, Sir relay lgana kiya zrori ha inverter k sath, or agr zrori ha to es ka kya faida ha, please explain.
Sir zarori bilkul b ni h ,wesey detail k lye yeh video h 👇👇👇👇
ua-cam.com/video/xgJZThmEvDY/v-deo.html
@@solar-wala-bhai2903 ok
I think koi b faida nhi hai already aroex series main complete computerized programming di hui hai jis se better setting kr sakhty hain. So, relay is just a waste of time
Sir isi lye log khtey hn k main ney solar system lagaya h or electric bill kam honey ke bjaye zyada ho gya h ,but its choice of people, i already said it not compulsory
220 volt ki
Yes
Yah kam UPS khud karte ha
♥♥♥
اس ریلے کے ساتھ LDR سنسر لگا دیں تو پاور آ ن آ ف کا مسلہ آ ٹو میں ہوجائے گا رات کو
G very soon Insha Allah
Sir iss say faida kaya hay.na hoto ??
Sir relay is used for maximum saving , if your utility off during day time ok it make sense that inverter will work with pv and battries, but after evening or at 10 pm when you swith on utility all the utility liad will go through from inverter and full night your inverter will run your load from utility and charging battries, but in this relay when you swith on utility no load will be run and no need to charge battries from solar , as battries charge with 500+ Watts, so what you save at da6 time will consume at night
Inverter ko 8 se 10 hours Ka araam milta hai
Iss Ka faida aapko May June mein pata lagay GA jab inverter bohat garam ho Jata hai
Exactly sir, thanks for support
Iska kya fayda hai bhai ?
Sir faida last pey btaya h k maximum saving kr saktey hn , iss terha apko battries utility sey charge ni krni parien ge
Sir ji 1st solar 2nd wapda ho or sath jab battery back pay havey load of ho aysa koi jugar hy😊
سر اگر دن میں pv سے کرنٹ آرہا ہوگا اس وقت واپڈا ہو خد سے بند کرنا پڑے گا کیا یہ خد ہی ایسا نہیں کر سکتی دن میں گھر pv پر چلائیے اور بیٹری بھی چارج کر دے اور جب رات کا وقت آے تو یہ واپڈا پر آجائے اور پھر وہی رات میں یہ اگر لائٹ چلی جائے تو یہ خد ہی پورا لوڈ بیٹری پر ڈال دے
اصل میں میرے گھر پر چینج اور لگا ہوا ہے اس طرح سے واپڈا کا بٹن روز خد بند کرنا پڑے گا تو رات میں لوڈ انویٹر سے واپڈا پر کر دو اور دن میں سولر پر اور چینج اور پر ریلے لگوا دو رات میں لائٹ جاے تو بیٹری چلے ورنا بند رہے اس طرح یہ سسٹم زیادہ بہتر رہے گا
Sir aisa he hota h iss system mn b
@@solar-wala-bhai2903 sir kindly share ur WhatsApp
03216557487 , sir please send voice message