sir mery pass Aerox iii3.2 invertor aur 4000 watts k panals aur 230 ampair ki 2 batteries hen raat 11:00pm light jati he aur load batteries per jatay he invertor off ho jata he (1 Fridge 1 TV 6 LED bulb 2 celling fans) ka load hota he .....lekin agar fridge light jany se pehly band ker do tu invertor off nahi hota he . is case me bhi invertor ki setting ka masla he? ya invertor me falt he? Faiz Ahmed from karachi
Sir settings mn problem hoga kion k itna load to 2.2 b asani sey chala leta h , ap kindly settings ke video bana kr mujey WhatsApp ker dien 03216557487, phr dekhta hon k kia issue ho sakta h
Sir uski waja yeh h k shamko hum battries ko charge ni honey detey , iss topic pey details k lye yeh video dekh lien apka concept clear ho jaye ga👇👇👇👇👇 ua-cam.com/video/D4wl8Hy4SaU/v-deo.html
Aoa, I am using Inverix Yukon 3.5 kw with 4 nos 550watt solar plate and 2nos Tubular batteries. I have also installed Ac Inverter 0.75 tons. But problem is when i open the AC in day time it drains my batteries, so why it is not taking full Ampere from Solar plates. Pls send some settings .Thanks
I have solar max 5 kw vm2. I have recently installed 4 Osaka T-2500 230 AH Tabular Batteries with the following settings. 01. SBU 02. 30A 05. USE 11. 2A ? 12. 47 13. 54 ? 16. ? 26. 57.6 27. 54.4 29. 40 Can you please recommend any changes? Also, I want to save the electric bill and set 11 to 2 A.
@@solar-wala-bhai2903 sir agar batteries full charge hain subha 10 say sham 5 tak wapda off kardaytay hain.kaya inverter work karta rahayga solar and batteries per load chalaa gaa.??
Sir mairay pass Phoenix ky 200 wali 2 batteries lagy ha or 2.2aerox invertor ha or 200 watt k 6 panals ha . Ap plz sitting #5,26,27,29 recommended setting reply kardain plz .....
@@solar-wala-bhai2903 sir apky dy hove setting bhot zabar10 ha .sir abi ak problem ha 1200wat k panals ha 11am par check keya tu 540 wat day Raha ha 30 v dy Raha ha or 22A dy Raha ha .jub k mairay khyal main 1200 nhe tu Kam say Kam 1000 watt tu Dayna chahye sir plz need ur guide line.........
Assalam o elikum janab ap ki video behtreen hy Mera sawal Ap na kitne penal connect kiya hy WO batay Or battery kn se achi ha es waqt Es ka sath kitne battery laga saktay hy 2.2kw ky sath or penal
Bhai mere pass 1.2 kw inverex ka inverter ha me us par medium size ka fridge chlata ho 150 watt k 6 pannel lgae ha A grade k me jb b fridge chlata ho aksar jhatka lga kr fridge on hota ha aksar light b band ho jati ha jb inverter dobara start krta ho to fridge sae chal jati ha yeh kia masla ha plz muje 1.2 ki 26/27 setting jo zabardast ha wo bta dain ta k meri fridge pora tark le sake
Sir agr battery FLD py rakhy tu ye default settings hoti. Kia ye. Setting b thek hai . Ya use py setting krni chahye? Meri ab ye setting hai. Battery cutt of voltage : 21.0 v back to grid vol: 23 v. Back to discharge 27.0 v.... Kindly guide me or send me USE option pye 3 no setting bta den. Thnx
Sir i have 1.2 Inverex Solar inverter, I have Acid Battery of 120 Amp, please guide me for setting of 26 and 27 or any best setting for bettery charging
@@solar-wala-bhai2903 i have Bought Tesla V2 5kw new model 2020 as per shop keeper he said it will Support net metering right now i am not interested in that but may be in future i know my connection and inverter both are Single phase.
AOA Sir setting no 5 mai fld or 13no ki setting mai mene 24.5 voltage set kiye hain but still inverter battery ko 27v tk wapda se charge krta hai evening mai aisa q?
Sir ap bhaion ke support hai or ap bhaion k Comments hn jo mazeed acha kam krney per force krtey hn , sir thanks a lot, and stay tuned for more upcoming videos
Sir possibility zaror h , or inverter k andar 150 amp ka fuse hota h battries pey hum jb 63 ya 100 use krtey hn to kbi kbi battries sey bht zyada amp out hotey hn jis ke waja sey 63 wala trip kr jata h
السلام علیکم بھائی میرے پاس 6 کلو واٹ کا سسٹم لگا ہوا ہے۔ اس میں مسئلہ یہ آ رہا ہے کے انورٹر ہیوی لوڈ زیادہ دیر تک نہیں اٹھا سکتا 30،40 منٹ تک بس۔ اس کے بعد 55 نمبر ایرر ا جاتا ہے۔ سسٹم شٹڈاون کرنے کے بعد جب ریسٹارٹ کر تا ہو تو پھر یہی ایرر پہلے کی نسبت جلدی ا جاتا ہے جیسے 10، 12 منٹ میں۔ کائنڈلی کوئی حل ہے اسکا تو گائڈ کر دیجیے
بھای جان اپ 2.2 اور3.2 صرف اسی کے اوپر ویڈیو بناتے رہتے ہو مہر بانی کرکے انویریکس 5.2 کی مکمل اور صاف ستھرا ویڈیو بھی بنا دو اسکے علاوہ اپ زرا سلو باتیں کریں تاکہ ہم صحیح طرح سے سمجھ سکے شکریہ عبدالقیوم پشاور
Sir uske waja h yeh h k uss time apka load zyada ho to battery b consume hoti h or sath battery charging b hoti h ,watts hidden mn charge krtey hn iss lye aisa show hota h ,its normal
Sir mera 2.2 kv inverex hai aur 5 solar panal lagye hue hai 330 watts ke parral main Pr us mn sirf 500 watts aur 18 ampar ban rha hai zyda nhi ho rhe is main kya masla hai plz reply
@@solar-wala-bhai2903 sir main ne load 1600 watts tk le gya pr bhi 450/500 watts se oper nhi gya kya masla hai main 4 panel series main lagye wah muje 800 watts 28 ampr mil rhe the abi main ne 5 panel parral main lagye sirf 500 watts mil rhe hai plz reply
Assalamu alaikum mohtarm Sir Plz Invrex 3.2kw ki mobile app setting main 👉Back to discharge voltage ki option ki samajh nahin a rahi woh bataen Kis liye hoti hai aur kahan kis value par set karni hai
Bahi mara 48v ka system ha jic pr ma na 185ah ki 4 battery talltubler lagi hain or load 350w ha Laken ya say sirf backup 7 hour dyti hain kiya ya thek ha ya ni ?
Sir meray pass 1.4 eco sol ka inverter ha wo battery overcharge ka fault de raha ha jab k battery bilkul new install ki ha plzzz uss ki settings k liye guide kar den
Sir I have Soler invertor but my electric bill is more then 6 thousand even my to load is (3celling fan +5leds+12watt+1fridge+1waterpump+ 2 pedestal fan only in night)
Sir mere pass inverex s1200 xp 720 waat ka ups he or main ne osaka ki 180amh ki battry lagaee he or 180 watt ki 2 plate or 200 watt ki 1 plate he. Pls mujhe is ki setting bata do
Bhe aslam alequm mere pas 2 tubler new battery 125ah ke hen 3.2 ka soler inverter he 5 plates 320 kw he battery rat ko 500 watt ke load per kitna backup de sak ti hen.
bro, I am using aerox III 3.2 green colour. it is continuously charging the battery even it reach at 28.8v or 28.9v voltage. I set bulk voltage 28.8 and floating voltage 27... please let me the issue..
Sir solar 150w ki 12 paltes hai 3 ki series hai pv 61 Hoti jesa hi ups ka Sath lagta pv 61 Sy start ho ka slow slow nechy aa ka 26 pa ruk jati 61 pa nai stable rehti asa q hai ???
Fronus pv2200 without solar koi seting bata den kis say bill me kami ay me sirf 1 120 Watts ka egg incubator chala rha ho inverter 24 hours charging krta rhta hy
Salam sir ji yehi Mera b masla hhe Mera inverter b krta he but aerox 1.2kw inverex red wala he to iski setting kiya rakhni hogi plz ansr jis se fridge asani se chal jae
@@solar-wala-bhai2903 ji mgr fridge on krte hi time 04 ,05 eror ajata he phr fridge ni chalta Phr me wpada on kr k fridge on krta hu taa iska tork wapda bardasht karle phr jb on hojata he to wapda off krta hu to chalta he mgr 15 se 20 minut bas
@@solar-wala-bhai2903 or jb k penal se inverter tk 6mm pure copper wire used ki he 32 amp DC breaker k sath or phr inverter se b betry k Liye 6mm wire or 125amp DC breaker used kiye hen han bas abi neutral alag ni Kara Jo abi tk comman chal ra he neutral ka b masla ho skta he
@@solar-wala-bhai2903 sir agr first setting SUB rakhian..tu phr bee bakee setting same rakhian gyain???..kindly reply me kyun kh maa battery ko as a last back up ph rakhna chahta hoo.
aor dosra yeh k hum agar ghar ka full lead battery per rakhain aor K Electric battery charge karta rahe Inverter ko tou kia setting karni ho gi, ghar ka load raat mein 500 watts hai
Sir hamre pass 2 dry battery he 150 liken backup nahi dete.. Abhi 1 month pehle le he. Hum ne shop wale ko wapes b ki os ne har trah se tasle kar le k battery me koie problem nahi he... Os ne battery full charge ki to kuch din sab tic raha liken ab pir backup problem ho raha he. Solar 10 lagaie he... 6 * 150 and 4* 400...ab me kia karo
sir fan ka hi issue araha hai battery full hai load 0 hai 3 din ho gay hai fan chal rahy hai bnd nhi hoty inverter heatup b nhi ho raha or load b 0 hai ye kia waja hai inverter musalsal awaz kar raha hai
Sir its upto you , if you want maximum saving then 12 no setting on 22 and 27 no setting on 25 , bcoz of this your batteries will charge from utility but not enough , as charging done with atleast 500+ watts , so 13 no on 27 , and if you set it at full then maximum time consume for charging and maximum loss of utility
اچھی کوشش لیکن آخر میں اصل بات نہیں سمجھ آسکی کہ بیٹری کی تمام سیٹینگز ہیں کیا 19 منٹ کی ویڈیو دیکھنے کے بعد بھی تشنگی باقی ہے کیونکہ آپ جس بھائی کو جواب دے رہے تھے اس کا تو مسئلہ شائد حل ہو گیا ہو لیکن عام یوزر کےلئے اس طرح فائدہ مند نہیں ہے. میرے خیال میں آخر میں بیٹری کی تمام سیٹینگز اکٹھی بتانی چاہیے تھیں شکریہ
Koi Bhai meei help kary GA me bht pershan Hun MERI SB sehri andary MN guzar rahi hain Mera off grid system Hy mujy setting krwnai Hy 185 ki 2bbattry Hain pr backup MN NH mil Raha 3 fab or 3 light b NH chalty RT 2 Bajy SB band ho jata Hy
Slam bhe subah ke time 12 baje 320 watt ke 5 platon ke pv out volt 172volt or 653 watt hote he kiyon volt ke hisab se watt to kam se kum 1000watt hone chahye.
@@solar-wala-bhai2903 sir yeh settings kerne k thori Der badd ups off hogya or ab ke show nahe ker Raha sirf battery pe chal Raha ha Maine restart bhi Kia reset bhi
Aoa h r u, farnous pv 3200 inverter hay software update ho gya hay 7 laken ab panel say load lanay ki bajaya sbu setting ma battery drain karta hy. Pehlay 1.5 kw or 2 kw tak jata ta load pay 180w kay 18 pannels hain 2 string ma lagay howay hain Abhi peak time pay with load 500 watt ta jata hy Thankd jzkAoa h r u, farnous pv 3200 inverter hay software update ho gya hay 7 laken ab panel say load lanay ki bajaya sbu setting ma battery drain karta hy. Pehlay 1.5 kw or 2 kw tak jata ta load pay 180w kay 18 pannels hain 2 string ma lagay howay hain Abhi peak time pay with load 600 watt ta jata hy Thankd jzk
مرحباً صديقي لدي بطارية z power tubular battery 240 Ah موضح على غلاف البطارية هذه القيم للشحن Cycle use : 15.4 v - 15.9 v Standby use :14.4 v - 14.9 v !!!!! هل هذه القيم مرتفعة ام صحيحة ؟ درجة الحرارة المحيطة بالبطارية °37C ارجوا منك ترجمة التعليق والرد على السؤال
Bhai ap ki vdo kuch samjh nhi aa rahi ap kabhi 26 py arahy ho kabhi 13 per...matlab ap ki vdo may koi continuity nhi. Kabhi ap idher jaty ho phir achank bilkul duaray option py chalay jaty ho.
میری پاس mah155 کے دو Narada بیٹریاں یے اور inverex 3.2 kw 2020 ماڈل کے ساتھ لگائی یے۔۔میرے پاس 250 watt کے 6 panel لگی ہیں۔جو مجھے 190 volt دیتا ھے۔اور واپڈا بھی ہے۔مگر میری بیٹریاں 27 Volts سے زیادہ جارج نہیں ہوتی جسکے وجہ سے 400 watt کا لوڈ backup صرف 2 گھنٹے چلتا ھے۔باقی setting نیچے ہے۔ 1: SBU 2:charging current 20 Mah 5: battery type USE 11:Utility charging current 20 13: Full 26: bulk charging 28.2 volt 27: floating charg 27 volt 29: Cut off charge 21 volt Any one help me please thanks
Bhae meri pas inverex 2.2 KW ka inverter ha jis ki sath ma na 250 Watt ki 4 Panels lagaye ha.ma na 2 penals ki Alag alag series banaye ha aur pir akher ma parrel connect keya ha.Ab ma na 435 Watt ki 2 perc technology panel purchsed kiye ha.baye esko kiss tarekh connect karna chye .aur agar 435 watt ki alag series bana ki iski sath connect karo tu wo 250 watt ki hisab se watt dega.ya pir charge controler ki sath kis tarah connact karo.taki muje 435 watt mil saki 250 ki panels ka volt 36.6 volt ki ha Aur 435 watt ka 44.6 volt deta ha Iski elana 2 nirada 155 amh ok 2 battery bi connect ha Baye apki reply ki reply ka wait karta ho My whatsup no +966563434109 Thanks
Sir better to use same panels , or ag laganey hn to parallel mn add kerien ,kion k 250 ke series ke waja sey 500 watts k arrey h to 435 jb add kerie gey to parallel mn add ho gien , but phr b apko better result chahey to same panels use krien
@@solar-wala-bhai2903 Sir Jo 250 volt ka ek series abi 72 Volt de raha ha agar 435 watt ko 250 watt ki sath parallel ma connect karo tu pir ye 44 volt dega.kyunki parallel ma jo kam volt ha usko consider kariga Thanks
May Allah make you very informative and basic video and our knowledge keeps increasing. May Allah reward you for this. Thank you.
Sir always i remember your intial support, jazak Allah, I try my best to transfer my knowledge to everyone as much i can
sir aap ne apni hi setting ko chaling kiya ha
sir mery pass Aerox iii3.2 invertor aur 4000 watts k panals aur 230 ampair ki 2 batteries hen raat 11:00pm light jati he aur load batteries per jatay he invertor off ho jata he (1 Fridge 1 TV 6 LED bulb 2 celling fans) ka load hota he .....lekin agar fridge light jany se pehly band ker do tu invertor off nahi hota he . is case me bhi invertor ki setting ka masla he? ya invertor me falt he? Faiz Ahmed from karachi
Sir settings mn problem hoga kion k itna load to 2.2 b asani sey chala leta h , ap kindly settings ke video bana kr mujey WhatsApp ker dien 03216557487, phr dekhta hon k kia issue ho sakta h
Aerox 1.2 py frig chla skty hn? Without inverter wali 200 wat wali
Very well excellent
Very informative video
Very easy lauanage
Very good behavior
Good show
God bless u
Jazak Allah
Sir soler plate 320 w wali 5 hen 3.3 kw hybird inverter he 2 tubler battery hen setting no2 SUb karni chah ye ya Sbu.
Sir agr maximum saving krna chahtey hn to SBU best h
@@solar-wala-bhai2903 SBu per battery ka back nahe rahta he kiyon
Sir uski waja yeh h k shamko hum battries ko charge ni honey detey , iss topic pey details k lye yeh video dekh lien apka concept clear ho jaye ga👇👇👇👇👇
ua-cam.com/video/D4wl8Hy4SaU/v-deo.html
Sir 5 plates per 1 ton inverter ac chal jata hay.kitna load hay ap ka .pv say kitnay watts miltay hain??
Aoa, I am using Inverix Yukon 3.5 kw with 4 nos 550watt solar plate and 2nos Tubular batteries. I have also installed Ac Inverter 0.75 tons. But problem is when i open the AC in day time it drains my batteries, so why it is not taking full Ampere from Solar plates. Pls send some settings .Thanks
Sir agr 5 ya 10 amp ley ra h to its notmal, wo sath he battries ko charge b kr deta h, no worry
JazakAllah
Please Suggest for 5kw solar what capacity size of Ideal battery used.
Sir better to use tall tublar 200 amh
I have solar max 5 kw vm2. I have recently installed 4 Osaka T-2500 230 AH Tabular Batteries with the following settings.
01. SBU
02. 30A
05. USE
11. 2A ?
12. 47
13. 54 ?
16. ?
26. 57.6
27. 54.4
29. 40
Can you please recommend any changes? Also, I want to save the electric bill and set 11 to 2 A.
Finally Apne Apni cv, flt, aur battery charging amp setting kia rakhi, aur kia yehi setting jo apne rakhi hai wohi 3kw inverter pr bhi rakh saktey hain?
G sir exactly same settings, both for 2.2 and 3.2
27 k jo floating voltage hain wo ap ne end main 26 set kar die the. Agar wo floating voltage 28v he rakhen to battery to kharab nai hogi?
Sir bilkul kharab ni hoge , but bhtr h k sp 26 ko 27v rakhien or 27 no ko 25 ya 25.5 tk rakhien
Sir 48 volt system k kitne rakhne hain?
Sir kindly make a video on nitrox 6kwa setting without using electricity thank you
Sir agar hum wapda off kardain sham 4.30 tak phir ya inverter batteries and solar ka saat aram say work karayga ??????
Sir very sorry,not getting your point, please explain
@@solar-wala-bhai2903 sir agar batteries full charge hain subha 10 say sham 5 tak wapda off kardaytay hain.kaya inverter work karta rahayga solar and batteries per load chalaa gaa.??
G bilkul sir , tabi to saving ho ge , or isi topic pey video under process h
@@solar-wala-bhai2903 thanks bilal bhai.Godbless u
I have 6kw nitrox inverter and I have four batteries of 90ah 12V
( kindly guide me
Battery Capacity?
A charge? and
A discharge ?
Sir ap ney batteries low capacity ke lagai hn , it's no recommended,
Although charge A not more then 15 & discharge 50A
Brother 90ah 12V ke 4 batteries hai - iss tarha 360ah key hisab say Charge / discharge set nahi karey gay?
Aoa sir, can we run refrigerator on 1800w homeage vertex 2414 invertor, solar panels of 2000watts are attatched?
Sir mairay pass Phoenix ky 200 wali 2 batteries lagy ha or 2.2aerox invertor ha or 200 watt k 6 panals ha . Ap plz sitting #5,26,27,29 recommended setting reply kardain plz .....
1 SOL
3 APL
5 USE
6 & 7 , DISABLE
12 , 23
13. 27
16 ,. CSO
23 , BYD
26. 28
27,. 27
29, 21
@@solar-wala-bhai2903 thank u sir for ur good response & very very useful information JazakaAllah .
Welcome
@@solar-wala-bhai2903 sir apky dy hove setting bhot zabar10 ha .sir abi ak problem ha 1200wat k panals ha 11am par check keya tu 540 wat day Raha ha 30 v dy Raha ha or 22A dy Raha ha .jub k mairay khyal main 1200 nhe tu Kam say Kam 1000 watt tu Dayna chahye sir plz need ur guide line.........
Sir ap ney load nai dala ho ga iss lye , kindly watch this
ua-cam.com/video/D4wl8Hy4SaU/v-deo.html
Assalam o elikum janab ap ki video behtreen hy
Mera sawal
Ap na kitne penal connect kiya hy WO batay
Or battery kn se achi ha es waqt
Es ka sath kitne battery laga saktay hy 2.2kw ky sath or penal
Sir mn ney 5 panels 330 watts k use kye hn , or tall tublar battries are best
Bhai mere pass 1.2 kw inverex ka inverter ha me us par medium size ka fridge chlata ho 150 watt k 6 pannel lgae ha A grade k me jb b fridge chlata ho aksar jhatka lga kr fridge on hota ha aksar light b band ho jati ha jb inverter dobara start krta ho to fridge sae chal jati ha yeh kia masla ha plz muje 1.2 ki 26/27 setting jo zabardast ha wo bta dain ta k meri fridge pora tark le sake
Sir Please contact on WhatsApp no for detail brief please, 03216557487
Ur voice and look like Ch shujahat hussain light .
Sir agr battery FLD py rakhy tu ye default settings hoti. Kia ye. Setting b thek hai . Ya use py setting krni chahye? Meri ab ye setting hai. Battery cutt of voltage : 21.0 v back to grid vol: 23 v. Back to discharge 27.0 v....
Kindly guide me or send me USE option pye 3 no setting bta den. Thnx
Sir 26 , 27 , 29 ke setting sirf use (user define) pey he kam kerien ge , Fld ke built-in setting ley ga wo b thek h
Thank you, mere pass inverex pro 1500 watts 24 v dc inventar hy,
Aik ghante me 4 Fan chale hy only,
Please Battery setting btae
Sorry, no idea
Sir i have 1.2 Inverex Solar inverter, I have Acid Battery of 120 Amp, please guide me for setting of 26 and 27 or any best setting for bettery charging
Sir already discussed on WhatsApp
@@solar-wala-bhai2903 thanx
Aoa Sir please tell the voltage for tubular battery equilization? Tx 3000 245 ah 48v(4 battries) 5kv system hy?
Very nice video.sir 60amp setting zaida nahe hay for batteries charging?????
Also tell k Single phase pe Pakistan main net metering hoti hai jab k inverter usko support krta ho and how is this work in setting
Sir 3 phase required,
@@solar-wala-bhai2903 i have Bought Tesla V2 5kw new model 2020 as per shop keeper he said it will Support net metering right now i am not interested in that but may be in future i know my connection and inverter both are Single phase.
Then please contact your nearest grid control centre
Sir i have inverex veyron 6000-48 kw system.Some time LCD venishs it goes to totally blue,how to reset the secreen LCD?
aoa brother h r u 1.2 inverex solr inverter ki solar kay bagair ups pay use karnay kay layay koi setting bata dain jis say kuch saving ho
Sir simply default pey rehney dien, default settings utility k hisab sey hoti hn
AOA
Sir setting no 5 mai fld or 13no ki setting mai mene 24.5 voltage set kiye hain but still inverter battery ko 27v tk wapda se charge krta hai evening mai aisa q?
Sir please send voice message on WhatsApp , 03216557487
Boss, I have 1.2 kw Inverex, it's fan is continuously running even after complete charging. Is it okay or have to make some changes in setup
Sir its normal , fan ka na chalna abnormal h
Sir first setting me sol,sub and sbu in me se konsi setting rakhna chaye
Inverter kon sa h apka?
@@solar-wala-bhai2903 humara inverter hai Ricardo micro
Kitney watts ka h?
@@solar-wala-bhai2903 3kv ka load chalta hai humara sir
Sir jb me apki video dekhti hun us me apne btaya tha sbu ka or ek video me apne sub ka btaya hai sir me apki video shok se dekhti hun
Professional way of explaining bro
Sir ap bhaion ke support hai or ap bhaion k Comments hn jo mazeed acha kam krney per force krtey hn , sir thanks a lot, and stay tuned for more upcoming videos
Sir mai ne youtube mai boht si video deki hai. Lekin waki sir apko man leya
Sir Jazak Allah, sab Allah ke madad h , or channel ka maksad b help kerna h srf
Sir AoA, kia yahi setting aerox 5.2 per bi ki ja sakti ha.
Sir bilkul , but uss mn SBU ni h،, uss ke jaga sub ker lien baki same
Sir AoA, ya system 48 volt ka ha, aur is may teeno option hn.
aur sir itni achi video banay per aap ky liye dhehro duaain aur bohat sa pyar kiun ky ye batain kisi ne nahi batain
Sir ap logon ke support or pyar he mera reward hn , JAZAK ALLAH,
Agar battery wala breaker din ma kisi waja sa trip hota ha to inverter kharab ho jai ga kya?
Sir possibility zaror h , or inverter k andar 150 amp ka fuse hota h battries pey hum jb 63 ya 100 use krtey hn to kbi kbi battries sey bht zyada amp out hotey hn jis ke waja sey 63 wala trip kr jata h
السلام علیکم بھائی میرے پاس 6 کلو واٹ کا سسٹم لگا ہوا ہے۔ اس میں مسئلہ یہ آ رہا ہے کے انورٹر ہیوی لوڈ زیادہ دیر تک نہیں اٹھا سکتا 30،40 منٹ تک بس۔ اس کے بعد 55 نمبر ایرر ا جاتا ہے۔ سسٹم شٹڈاون کرنے کے بعد جب ریسٹارٹ کر تا ہو تو پھر یہی ایرر پہلے کی نسبت جلدی ا جاتا ہے جیسے 10، 12 منٹ میں۔ کائنڈلی کوئی حل ہے اسکا تو گائڈ کر دیجیے
بھای جان اپ 2.2 اور3.2 صرف اسی کے اوپر ویڈیو بناتے رہتے ہو مہر بانی کرکے انویریکس 5.2 کی مکمل اور صاف ستھرا ویڈیو بھی بنا دو اسکے علاوہ اپ زرا سلو باتیں کریں تاکہ ہم صحیح طرح سے سمجھ سکے شکریہ
عبدالقیوم پشاور
Sir channel per veryon 5.2 , 2.5, nitrox 5.2 ke video mojood hn
Sir main ne 1.2kv inverx installat kia jb main us pe load dalta ho wo pv se watt kam lena shoro kar deta hy plz help me
Sir uske waja h yeh h k uss time apka load zyada ho to battery b consume hoti h or sath battery charging b hoti h ,watts hidden mn charge krtey hn iss lye aisa show hota h ,its normal
Sir mera 2.2 kv inverex hai aur 5 solar panal lagye hue hai 330 watts ke parral main
Pr us mn sirf 500 watts aur 18 ampar ban rha hai zyda nhi ho rhe is main kya masla hai plz reply
Sir ap load ziada chala k dekhien, jb load 400 watts ka hoga to controller 500 watts tk he ley ga
@@solar-wala-bhai2903 sir main ne load 1600 watts tk le gya pr bhi 450/500 watts se oper nhi gya kya masla hai main 4 panel series main lagye wah muje 800 watts 28 ampr mil rhe the abi main ne 5 panel parral main lagye sirf 500 watts mil rhe hai plz reply
Please contact me on WhatsApp no , 03216557487
@@mdinbugti306 bhai
Bhai ap apna WhatsApp number send kro
Sir aap ki ye video help full hai
Assalamu alaikum mohtarm Sir
Plz
Invrex 3.2kw ki mobile app setting main 👉Back to discharge voltage ki option ki samajh nahin a rahi woh bataen
Kis liye hoti hai aur kahan kis value par set karni hai
Bahi mara 48v ka system ha jic pr ma na 185ah ki 4 battery talltubler lagi hain or load 350w ha Laken ya say sirf backup 7 hour dyti hain kiya ya thek ha ya ni ?
Sir meray pass 1.4 eco sol ka inverter ha wo battery overcharge ka fault de raha ha jab k battery bilkul new install ki ha plzzz uss ki settings k liye guide kar den
Agr tezab wali battery h to simply flodded per rakh dien
24volt k pair ko kitny ampars par charge Karen 185ah 4batrees flotiong or bullk volt
Sir maximum 50 amp
Sir kia asa setting krne se battery backup zyada dy ga
G sir zaror dey ga INSHA ALLAH
Sir I have Soler invertor but my electric bill is more then 6 thousand even my to load is (3celling fan +5leds+12watt+1fridge+1waterpump+ 2 pedestal fan only in night)
Please guide me to control my bill and MAY ALLAH GIVE HAPPINEES IN YOUR WHOLE LIFE
Jazak Allah sir
Sir ap ney wapda direct de hui h ? Panels kitney watts k hn ?
Or inverter kon sa h ?
bhai fans walay computer main fan katni consume hooty hai question kaisa kertay ho
7
Sir mere pass inverex s1200 xp 720 waat ka ups he or main ne osaka ki 180amh ki battry lagaee he or 180 watt ki 2 plate or 200 watt ki 1 plate he. Pls mujhe is ki setting bata do
Bhe aslam alequm mere pas 2 tubler new battery 125ah ke hen 3.2 ka soler inverter he 5 plates 320 kw he battery rat ko 500 watt ke load per kitna backup de sak ti hen.
Sir approximately 4 hours on 500 watts, din mn to koi problem ni ap 1800 watts b easily chala saktey hn mn raat ka bata raha hoon,
@@solar-wala-bhai2903 sir max charging current 30amp 2 tubler battery wapda source per kitne amp pe charge hote he or kina time legen.
Sir 500 watts to 700 watts , time not confirmed, but may be 2 hours or +
bro, I am using aerox III 3.2 green colour. it is continuously charging the battery even it reach at 28.8v or 28.9v voltage. I set bulk voltage 28.8 and floating voltage 27... please let me the issue..
bhai Bulk voltage ke setting konse number par hai our Floating kis number hai?
Sir solar 150w ki 12 paltes hai 3 ki series hai pv 61 Hoti jesa hi ups ka Sath lagta pv 61 Sy start ho ka slow slow nechy aa ka 26 pa ruk jati 61 pa nai stable rehti asa q hai ???
Fronus pv2200 without solar koi seting bata den kis say bill me kami ay me sirf 1 120 Watts ka egg incubator chala rha ho inverter 24 hours charging krta rhta hy
Salam sir ji yehi Mera b masla hhe Mera inverter b krta he but aerox 1.2kw inverex red wala he to iski setting kiya rakhni hogi plz ansr jis se fridge asani se chal jae
Sir panels kitney watts k hn ?
Baki setting by default b rakhien to fredge chalta h agr uss mn koi masla na ho to
@@solar-wala-bhai2903 sir mere pas jinko k 460watt k 2 penal hen Jo k perarell me lagae hen or inverter to new he
To phr to to ap ka fredge easily chal sakta h
@@solar-wala-bhai2903 ji mgr fridge on krte hi time 04 ,05 eror ajata he phr fridge ni chalta
Phr me wpada on kr k fridge on krta hu taa iska tork wapda bardasht karle phr jb on hojata he to wapda off krta hu to chalta he mgr 15 se 20 minut bas
@@solar-wala-bhai2903 or jb k penal se inverter tk 6mm pure copper wire used ki he 32 amp DC breaker k sath or phr inverter se b betry k Liye 6mm wire or 125amp DC breaker used kiye hen
han bas abi neutral alag ni Kara Jo abi tk comman chal ra he neutral ka b masla ho skta he
Sir 26 pa krna sa tublar battery to full nai charge ho gi????
Set Bulk volt = 28.2v and Float Volt = 26.5v and charging amperes 10% of battery (AH) capacity.
Bhai jan mujhe din sy sham tak solor sy chalana hai phir sham ko wabda se phir agar wabda jae gi tb battery pe ae yeh iski setting bata dy 2.2 kw ki
Sir Please message at my WhatsApp no 03216557487, i will guide you in DETAIL
Sir salam i have 3.2, kv inverter which showing low watt i have installed 2000 watt panels total load is 0.75 submersible pump
Sir maximum load dal k check kerien ,
Sir final hum phir bulk aur floting ke kya settings kry aur 5 no pr use he rhny da plz... Replay
1 SBU
3 APL
5 USE
6 & 7 , DISABLE
12 , 22.5
13. 27.5
16 ,. CSO
23 , BYD
26. 28
27,. 27
29, 21
@@solar-wala-bhai2903 sir agr first setting SUB rakhian..tu phr bee bakee setting same rakhian gyain???..kindly reply me kyun kh maa battery ko as a last back up ph rakhna chahta hoo.
G sir bilkul ap SUB, rakhien or baki settings normal he rakhien to koi masla ni
battery soc 100 but still inverex nitrox 3kv solar inverter charging DIB-260 daewoo battery, 27.6 float v, 28.6 absorption v, please guide
Voltage limit KO 1 volt Bhara dien
@@solar-wala-bhai2903 voltage limit Matlab float voltage?
🌺🌺🌺ماشاءاللہ🌺🌺🌺
Very nice for torque load
Inverex ka 2.5 ka ups ha wo solar sy jb chang hota ha bee nhi data is ka kea masl ho sakt hai
aor dosra yeh k hum agar ghar ka full lead battery per rakhain aor K Electric battery charge karta rahe Inverter ko tou kia setting karni ho gi, ghar ka load raat mein 500 watts hai
Sir sbu setting hoti h, 12 or 13 no ke setting krni hoge
Thanks JazakAllah
Sir hamre pass 2 dry battery he 150 liken backup nahi dete.. Abhi 1 month pehle le he. Hum ne shop wale ko wapes b ki os ne har trah se tasle kar le k battery me koie problem nahi he... Os ne battery full charge ki to kuch din sab tic raha liken ab pir backup problem ho raha he. Solar 10 lagaie he... 6 * 150 and 4* 400...ab me kia karo
Trion k ups ki setting batein 180ah battery , load shedding almost 1 hour in two days
Sorry,no idea
sir fan ka hi issue araha hai battery full hai load 0 hai 3 din ho gay hai fan chal rahy hai bnd nhi hoty inverter heatup b nhi ho raha or load b 0 hai ye kia waja hai inverter musalsal awaz kar raha hai
Mera inverter changing stop nay karta jis ki waja se battery heetup ho kr pool gain aur kharab ho gyn
Kia waja ho sakty h
Excellent
Sir kindly final battery setting bta Dy? Bulk. Floating?
Sir bulk 28, and floating 26.5,
@@solar-wala-bhai2903 sir kindly tell back to grid voltage aur back to discharge voltage ki b bta den? Thnx
Sir its upto you , if you want maximum saving then 12 no setting on 22 and 27 no setting on 25 , bcoz of this your batteries will charge from utility but not enough , as charging done with atleast 500+ watts , so 13 no on 27 , and if you set it at full then maximum time consume for charging and maximum loss of utility
اچھی کوشش
لیکن آخر میں اصل بات نہیں سمجھ آسکی کہ بیٹری کی تمام سیٹینگز ہیں کیا
19 منٹ کی ویڈیو دیکھنے کے بعد بھی تشنگی باقی ہے کیونکہ آپ جس بھائی کو جواب دے رہے تھے اس کا تو مسئلہ شائد حل ہو گیا ہو لیکن عام یوزر کےلئے اس طرح فائدہ مند نہیں ہے. میرے خیال میں آخر میں بیٹری کی تمام سیٹینگز اکٹھی بتانی چاہیے تھیں
شکریہ
Sir thanks for observation, your point is great but i am always here to help people, but in coming video a summary of video should be at the end
Lovely..
Please make a detailed video too on bypass enable option...
Ok sir ,with in 3 days please
Koi Bhai meei help kary GA me bht pershan Hun MERI SB sehri andary MN guzar rahi hain Mera off grid system Hy mujy setting krwnai Hy 185 ki 2bbattry Hain pr backup MN NH mil Raha 3 fab or 3 light b NH chalty RT 2 Bajy SB band ho jata Hy
Sir leave a message on WhatsApp,03216557487 ONLY WhatsApp please
@@solar-wala-bhai2903 okk sir kal afternoon MN kal msg krta Hun mujy bus setting krwa dain plzzzzzzzzz
Sir aap Andary mein Anak kyun laga kar bathy howay hain ..😂😂😂اندھیرے میں عینک ۔۔عجیب بات ھے ۔
Good work
Sir ap sari baat tafseel sa samjata ho
Sir 1.2 aerox ki settings b krwa dain plz
Sir allah pak ap ko khush kra
Jazak Allah sir
Slam bhe subah ke time 12 baje 320 watt ke 5 platon ke pv out volt 172volt or 653 watt hote he kiyon volt ke hisab se watt to kam se kum 1000watt hone chahye.
میرے پاس 2.2 اینورکس اینورٹر ھے جو کہ مسلسل جارجنگ کرتا رہتا ھے اور بیٹری کو اوور چارج کرتا ھے آٹو سٹاپ نہیں ہوتا اسکا کیا حل ھے
Sir apko kesey pata k overcharge krta h
100 ampere ki 2 batteries hai (24 volts) unki setting Kia rakhain ? End ma samajh nahe aya
1 SOL
3 APL
5 USE
6 & 7 , DISABLE
12 , 23
13. 27
16 ,. CSO
23 , BYD
26. 28
27,. 27
29, 21
@@solar-wala-bhai2903 I have latest 3.2 aerox ferozy color.. I don't have SOL at 1
@@solar-wala-bhai2903 sir yeh settings kerne k thori Der badd ups off hogya or ab ke show nahe ker Raha sirf battery pe chal Raha ha Maine restart bhi Kia reset bhi
Then SBU is best
Sir KINDLY send video on my WhatsApp no , 032I 6557 487
jb dolar ya wapda battery ko full kr deta he to sara load battery par chlne lg jata he esa ku hota he bhai smaj ni a rhe iski wja zrur btao
Nice g
❤❤❤
sir thanku
Aoa h r u, farnous pv 3200 inverter hay software update ho gya hay 7 laken ab panel say load lanay ki bajaya sbu setting ma battery drain karta hy.
Pehlay 1.5 kw or 2 kw tak jata ta load pay
180w kay 18 pannels hain 2 string ma lagay howay hain
Abhi peak time pay with load 500 watt ta jata hy
Thankd jzkAoa h r u, farnous pv 3200 inverter hay software update ho gya hay 7 laken ab panel say load lanay ki bajaya sbu setting ma battery drain karta hy.
Pehlay 1.5 kw or 2 kw tak jata ta load pay
180w kay 18 pannels hain 2 string ma lagay howay hain
Abhi peak time pay with load 600 watt ta jata hy
Thankd jzk
Already discussed on WhatsApp
مرحباً صديقي
لدي بطارية z power tubular battery 240 Ah
موضح على غلاف البطارية هذه القيم للشحن
Cycle use : 15.4 v - 15.9 v
Standby use :14.4 v - 14.9 v
!!!!!
هل هذه القيم مرتفعة ام صحيحة ؟
درجة الحرارة المحيطة بالبطارية °37C
ارجوا منك ترجمة التعليق والرد على السؤال
AA sir mery pass inverex 3.2 aerox kw 6 panels 320 watt aur 2 tubular battery 110Ah ke lagi hy .kindly important setting Bata dein
Bhai ap ki vdo kuch samjh nhi aa rahi ap kabhi 26 py arahy ho kabhi 13 per...matlab ap ki vdo may koi continuity nhi. Kabhi ap idher jaty ho phir achank bilkul duaray option py chalay jaty ho.
AP bahot tafsel say batta rahay ho abi tak koi youtub may nahi battaya
Sir Allah ka karam h ,or ap bhaion ke support h ni to mn to iss qabil nai hon
24 main 4batrees ko kitny ampar Dana or bulk volt kitny do
Sir battries kitney Amp ke hn?
@@solar-wala-bhai2903 185ah TR 1800 4batrees hain kitny ampar don flloting or bulk kitny rakhon or 24vt wala inverter hai
40 amp , maximum 50 amp ,
Bulk 28, floating 26.5
@@solar-wala-bhai2903 mujhy full backup chaiye kun k sirf solar system hai wapda not available
Inverter konsa hai ?
Nice video and good effort bro
Sir apna whatsapp dain maine 2.2kw ki setting samajni hai, non solar setup hai,
03216557487 WhatsApp only
24 100 ki battry hai ous k bluk our floting kia rake
I have fronus 3.2 inverter which always charges that make alots of noise
Bluetooth kese on krte hai is inverter ka?
Sir Bluetooth option ni h , wifi device k sath ap use kr saktey hn ya Lan cable sey
Ok sir
lan cabil sa kasa use hoga . direct laga k dakhi not working
میری پاس mah155 کے دو Narada بیٹریاں یے اور inverex 3.2 kw 2020 ماڈل کے ساتھ لگائی یے۔۔میرے پاس 250 watt کے 6 panel لگی ہیں۔جو مجھے 190 volt دیتا ھے۔اور واپڈا بھی ہے۔مگر میری بیٹریاں 27 Volts سے زیادہ جارج نہیں ہوتی جسکے وجہ سے 400 watt کا لوڈ backup صرف 2 گھنٹے چلتا ھے۔باقی setting نیچے ہے۔
1: SBU
2:charging current 20 Mah
5: battery type USE
11:Utility charging current 20
13: Full
26: bulk charging 28.2 volt
27: floating charg 27 volt
29: Cut off charge 21 volt
Any one help me please thanks
No 2 settings pey charging current 20 sey 30 ya 40 kr dien
❤
بھائی میرا یو پی ایس اوور چارج کر رہا ہے بیٹری فل ہونے پر آف نہیں ہوتا ھیرے پلیز مدد کریں
Kindly send message on WhatsApp no 03216557487
Bhai jan mjhe kia ap ka mob num mil jae ga ek do chese pochne ha aerox 2.2 kw ka ek do masla ha
Sir whatsapp no , 03216557487
Bhae meri pas inverex 2.2 KW ka inverter ha jis ki sath ma na 250 Watt ki 4 Panels lagaye ha.ma na 2 penals ki Alag alag series banaye ha aur pir akher ma parrel connect keya ha.Ab ma na 435 Watt ki 2 perc technology panel purchsed kiye ha.baye esko kiss tarekh connect karna chye .aur agar 435 watt ki alag series bana ki iski sath connect karo tu wo 250 watt ki hisab se watt dega.ya pir charge controler ki sath kis tarah connact karo.taki muje 435 watt mil saki
250 ki panels ka volt 36.6 volt ki ha
Aur 435 watt ka 44.6 volt deta ha
Iski elana 2 nirada 155 amh ok 2 battery bi connect ha
Baye apki reply ki reply ka wait karta ho
My whatsup no +966563434109
Thanks
Sir better to use same panels , or ag laganey hn to parallel mn add kerien ,kion k 250 ke series ke waja sey 500 watts k arrey h to 435 jb add kerie gey to parallel mn add ho gien , but phr b apko better result chahey to same panels use krien
@@solar-wala-bhai2903 Sir Jo 250 volt ka ek series abi 72 Volt de raha ha agar 435 watt ko 250 watt ki sath parallel ma connect karo tu pir ye 44 volt dega.kyunki parallel ma jo kam volt ha usko consider kariga
Thanks
Ns invater3 kv ke seting battay
Ns complete name h ?
شجاعت ہاشمی
Tasla company achi hy
Achi h sir