Hello sir.h r u.sir aap ek video 3.3 card synchronize ki bhi bnaye with all 3.3 card kya kya kha kha se control hota hai .sir ho sakye to dg (Generator) per hi sab kuch guied karey.thxssss
Sir 125 kva ka d g set hi kirlosker 60 amp pr jakr voltag drop karta hi d c 120 v tk ho jati hi rootor feeld exitor rebonding kr deya hi plz problem solv karin
45 kVA Cummins Dg set silent non indastryal ac supply nahi rahta hai usme AVR available hota hea mere Dg set mea AVR available nahi hai mena dekha to altanator khola to usmea AVR nahi rahta or black colour ka driver jesa kuch hea
High ac voltage issue in cummins 15 kva dg. Output voltage 230 but dg tripped by showing high ac voltage within 2 to 3 sec after start. What is the reason?
Real teacher ho sir ji aap jai hind
Sir acha se smjha aa gya bht acha se smjha ya sir thaku
Very good👍👍👍 sir thanks for information u r great👏👏👏👏
Good ❤ astad
am from pakistan
Bahut acha samzaya sir 🙏🙏🙏🙏
Super explain
Dear Sir Thank You So Much 🙏
Thnx sir nice information..
Valo good
PSO 500pdf Hai Kya
Thanks sir ji
Thanks so much sir 🙏🙏🙏🙏🙏🙏
Avr as480 ka voltage settings bateyea
Super sir
Avr change kiya to bhi error aati hea faulty avr dusrea DG mea chalta hea to kya issue hoga
Hello sir.h r u.sir aap ek video 3.3 card synchronize ki bhi bnaye with all 3.3 card kya kya kha kha se control hota hai .sir ho sakye to dg (Generator) per hi sab kuch guied karey.thxssss
Ok
Am fine brother
Sir please DG synchronising per video please
Sir high speed problem plz explain sir
Sir we have some problem in 320 kva DG, when we put load on dg it stops and fault code 1446 appears please help.
Sir speed bias kya hota hai please video banana
Next week
Pls explain Synchronization with pcc3.3
Now synchronisation pannel not available I will try
Sir Dg neutral ko Erth sa lagao to volts hi hojat ha
No
Low AC voltage k se hota hai
Exiction voltage kaha se aata h sir 🙏🏻🙏🏻🙏🏻
Sir exition volt akbar13
Akbar16.5 q aya
Sir 125 kva ka d g set hi kirlosker 60 amp pr jakr voltag drop karta hi d c 120 v tk ho jati hi rootor feeld exitor rebonding kr deya hi plz problem solv karin
Excitation voltage 120 hai ?
@@technicalmanish9032 sir load 60 amp dalne pr DC 120 ho jati ho
Please call me on my whatsaap no +919839787404
Pls english explain essay to understand me sir
45 kVA Cummins Dg set silent non indastryal ac supply nahi rahta hai usme AVR available hota hea mere Dg set mea AVR available nahi hai mena dekha to altanator khola to usmea AVR nahi rahta or black colour ka driver jesa kuch hea
Please send me pics on WhatsApp no +919839787404
High ac voltage issue in cummins 15 kva dg.
Output voltage 230 but dg tripped by showing high ac voltage within 2 to 3 sec after start.
What is the reason?
Same problem.how to rectify
Hi sir men power plant me Kam karta hun sir ge apka number mile ga plz plz sir
+919839787404
@@technicalmanish9032 sir engin ki bare me mujhi SB Kusch btao this my new feld ok sir thenkx
15 kVA and 45 kVA AVR same hota hai
Yes
but why use facemask on camera?
Sir whatsapp grpup ma kra ko