How to connect Encoder with S7-1200 ? || High Speed Counter HSC || TIA PORTAL || Lesson#13

Поділитися
Вставка
  • Опубліковано 21 жов 2024

КОМЕНТАРІ • 44

  • @ymmijjohnsson
    @ymmijjohnsson 9 місяців тому

    keep up the good work. There are many channels with the Siemens tia portal, but not many that are as informative as yours

  • @medosust
    @medosust Рік тому +1

    Very helpful especially wiring

  • @gilbertopadovani
    @gilbertopadovani 7 місяців тому

    Thanks for the explanation.
    Could you tell me where to buy the Seiki CB2000-HC encoder? I tried searching but without success. Thanks in advance.

  • @hymdt
    @hymdt Рік тому

    you saved our day with this information ... thanks

  • @rashidchibvuri2036
    @rashidchibvuri2036 5 місяців тому

    Great explanation sir thank you.

  • @allagomar6033
    @allagomar6033 3 роки тому

    Thank you so much bro i wish to continu like this video

  • @pajur
    @pajur 4 місяці тому

    Why is Z signal connected to I0.2? Does it have any sense here? According to S7-1200 manual, only A/B signals are needed.

  • @electromecanica_automatismos
    @electromecanica_automatismos 2 роки тому

    By the way...in this wiring diagram I suppose that your Rotary Encode is NPN output (If not --- PNP--- M (0V) must be connected to 1M.... that`s right?)

  • @nirutg5130
    @nirutg5130 2 роки тому

    Thank you very much

  • @rincebaby145
    @rincebaby145 8 місяців тому

    Nice video.but how we get reset input the encoder

  • @shameehaajmal1517
    @shameehaajmal1517 2 роки тому

    Great video! Can I know why all three encoder signal wires are connected to the PLC?

    • @EASYPLCTRAINING
      @EASYPLCTRAINING  2 роки тому +1

      Good question! three wires to detect if the encoder is moving in CW or CCW direction

  • @thomassaook7787
    @thomassaook7787 4 роки тому +1

    simple & accurate

  • @botas82
    @botas82 3 роки тому

    Great vídeo, thanks a lot.

  • @tourdhorizon97
    @tourdhorizon97 3 роки тому +2

    2000 pulses per Revolution, how is it possible for this small encoder ????

  • @tarekmohsen7572
    @tarekmohsen7572 3 роки тому

    Thank you

  • @mahmudrajon9104
    @mahmudrajon9104 4 роки тому

    very good work.

  • @sarpturker5034
    @sarpturker5034 3 роки тому

    Good tutorial. But one think i cant figure out. Where is the Orange cable Z-phase I0.2? Cant see it in Hardware Inputs?

  • @rokibhasan2823
    @rokibhasan2823 4 роки тому

    Can i change the input in monitor mode without using encoder??

  • @ahmedrezk2281
    @ahmedrezk2281 4 роки тому +3

    The jumpre on L+and1m error

  • @kingofthering1224
    @kingofthering1224 9 місяців тому

    why the counter value reach out to 1700.....??? it must be 1500 only ??? I'm right

  • @muhammaddanishhameed9865
    @muhammaddanishhameed9865 3 роки тому

    Bhai, encoder se motor ka rpm kis tarah calculate ka sakta hein siemens mein

  • @balajisekar2071
    @balajisekar2071 3 роки тому

    How to connect two or more encoder in one plc

    • @EASYPLCTRAINING
      @EASYPLCTRAINING  3 роки тому +1

      You can install encoder input cards with the plc

  • @MaterieUltimeUnofficialChannel
    @MaterieUltimeUnofficialChannel 4 роки тому +1

    why +24V is connected to 0V?

  • @yadavsaroj1657
    @yadavsaroj1657 4 роки тому

    Sir please same program in omron plc cx-program

  • @vorapobautomation9760
    @vorapobautomation9760 4 роки тому

    How about S7-1500 HSC ?

  • @decentmkiza8570
    @decentmkiza8570 4 роки тому

    Can you do a video of a stepper motor connection and programming

  • @desifiedCanada
    @desifiedCanada 2 роки тому

    How to reset count value ?

    • @EASYPLCTRAINING
      @EASYPLCTRAINING  2 роки тому +1

      Move zero in the data register

    • @desifiedCanada
      @desifiedCanada 2 роки тому

      @@EASYPLCTRAINING is there any option for external reset ?

    • @EASYPLCTRAINING
      @EASYPLCTRAINING  2 роки тому +1

      Connect a push button with the PLC, use thus push button signal to move the zero to the encoder data register

    • @desifiedCanada
      @desifiedCanada 2 роки тому

      @@EASYPLCTRAINING should we move zero in IW1000 or QW1000?

    • @ghouseahmed4u
      @ghouseahmed4u 2 роки тому

      @@EASYPLCTRAINING can we do like this - "Since pulses are DInt format, after counter finishes counting until 2147483647, then can i move "1" to ID1000 directly, so that the cycle repeats?

  • @peppealfano65
    @peppealfano65 4 роки тому

    non si vede bene

  • @nazmikaddora1457
    @nazmikaddora1457 3 роки тому

    Thank you so much