Siemens S7-1200 PLC encoder high speed counter setup in TIA portal and TP700 HMI programming. Eng

Поділитися
Вставка
  • Опубліковано 3 сер 2024
  • Siemens S7-1200 PLC encoder high speed counter setup in TIA portal and TP700 HMI programming. Please see manual form Siemens to check out programming and set up examples.
    Siemens HSC application examples: cache.industry.siemens.com/dl...
    Siemens S7-1200 PLC Encoder Wiring and Fault finding tips: • Siemens S7-1200 PLC en...
    Website: igselectronics.co.uk/
    eBay store: www.ebay.co.uk/str/igselectro...
    Linked in: / ingus-sudints-1b2a2517a
  • Наука та технологія

КОМЕНТАРІ • 14

  • @mini-momentclips
    @mini-momentclips 6 місяців тому

    Your English speaking is so nice for non native speaker ❤❤
    Very knowledgeable tutorial
    Keep it up

  • @bendjakovic955
    @bendjakovic955 Рік тому +1

    Bloody brilliant!! You have a new subscriber Ingus 👍

  • @Aeeeeelex
    @Aeeeeelex Рік тому +1

    You’re the best. Keep up the good work!

  • @user-ib6hl4cp5q
    @user-ib6hl4cp5q Рік тому +1

    Such nice content :) Thank you so much. I just recently found your channel. I will be watching a lot of your videos from now on!
    One question, why are you talking about an S400 PLC on this video and the previous one? I only see you using a S1200 and S1500 on the video.

  • @thomassaook7787
    @thomassaook7787 2 роки тому +1

    Great job, thank you

  • @kme8134
    @kme8134 2 роки тому +1

    This is great, thanks boss.

  • @davidbooth529
    @davidbooth529 2 роки тому +1

    excellent vid. Well done!

  • @framos9991
    @framos9991 Рік тому +1

    Helpful! Thank you!👌

  • @kondito88
    @kondito88 4 місяці тому

    Thx

  • @tpd-jy7qm
    @tpd-jy7qm 2 місяці тому

    Thanks for explanation, can you explain how to convert the results to RPM?
    Which encoder did you use here?

  • @tpd-jy7qm
    @tpd-jy7qm 3 дні тому

    I am using Push-Pull encoder, and i conected A, B and Z to 0.0, 0.1 and 0.2 inputs of 1215C PLC. Program is counting something, but I am not sure are reading correct or not ("countersingle phase" doesn't read anything at all). Can someone explain how this could be fixed, so it can work properly with my encoder? Thanks.

  • @1986ah
    @1986ah Рік тому +2

    What if the counting value reaches the upper limit of a double integer? How could we reset it again?

    • @veys9655
      @veys9655 6 місяців тому +1

      it reset it by itself. Then it start again at the begining value!