Campbell-Sevey - Mechanical Condensate Pump

Поділитися
Вставка
  • Опубліковано 11 вер 2024
  • Here is some brief information about the Mechanical Condensate Pump.
    For more information visit www.campbell-sevey.com

КОМЕНТАРІ • 11

  • @firdausNusa-w6m
    @firdausNusa-w6m 2 місяці тому

    Good reference Thank You Sir

  • @Grilloale93
    @Grilloale93 4 роки тому +2

    Perfect explanation, great model. Thanks :-)

  • @karamaske97
    @karamaske97 Рік тому

    very good explanation, Thanks a lot

  • @yanikivanov
    @yanikivanov 3 роки тому +1

    thnx for exellent explanation..

  • @fgofgau
    @fgofgau 6 місяців тому

    What happens when the driving gas (compressed air as shown) stops supplying the return pump? Should I add a backflow preventer to my compressed air line? Or would it be better to power the return pump with steam only. Thanks for the Video !

  • @gulzarhaider5844
    @gulzarhaider5844 2 роки тому

    very good job and good working dear sir

  • @eegg6954
    @eegg6954 Рік тому

    "Alternating receiver" or "Boiler return trap" from the 1920's!

  • @mtkhan646
    @mtkhan646 7 років тому

    Hi, Do we use these pumps as Continues cycle like other electrical pumps Like overhead tank? we have 10-12 bar steam available at system.

  • @subhashpareek3159
    @subhashpareek3159 3 роки тому

    If out nrv leaking....what happened.
    PL reply

  • @rehmaneng9067
    @rehmaneng9067 4 роки тому +1

    U need only flot