Out Of Specification (OOS) Investigation Phase Ia & Phase Ib (MHRA)

Поділитися
Вставка
  • Опубліковано 23 лис 2024

КОМЕНТАРІ •

  • @saradaverans
    @saradaverans 2 роки тому +4

    Sir, please explain phase-II and phase-III also 🙏

  • @rohitbrahmbhatt5462
    @rohitbrahmbhatt5462 2 роки тому +2

    Correct method and specifications are followed or not that's also considered in Phase-1A

  • @tejaswarupalolla4421
    @tejaswarupalolla4421 2 роки тому +2

    So nice please upload the phase 2

  • @sambireddydantu55
    @sambireddydantu55 2 роки тому +2

    Hi sir, can you please share OOS phase 2 and 3 investigation presentation also.

  • @lakshminarayana7064
    @lakshminarayana7064 Рік тому

    Super sir, thank you very much, I have learnin more from thi

  • @jrpmarket8538
    @jrpmarket8538 Рік тому

    खुपच छान सर... धन्यवाद...

  • @lathashree9201
    @lathashree9201 Місяць тому

    All obvious error comes to analyst error only right........

  • @ramakrishnaguttula7941
    @ramakrishnaguttula7941 Рік тому +1

    Good information sir

  • @anoopsingh714
    @anoopsingh714 9 місяців тому +1

    Nice explaination

  • @kishordangat684
    @kishordangat684 2 роки тому

    System suitability failure is also obevios errors

  • @user-um9rw5ov7l
    @user-um9rw5ov7l 4 місяці тому

    Can you do video about validation processes

  • @bramanaranjan706
    @bramanaranjan706 Рік тому

    If solutions are not stable, how to find the analyst mistake in preparation?

  • @user-um9rw5ov7l
    @user-um9rw5ov7l 4 місяці тому +1

    I can’t thank you enough

  • @rajeshkumarsrivastava349
    @rajeshkumarsrivastava349 4 місяці тому

    WhatsApp group is showing full.... please do the needful I need to join

  • @ramd9111
    @ramd9111 Рік тому +1

    TQ sir ... Nice explained

  • @pragyashree1834
    @pragyashree1834 2 роки тому +1

    Obvious errors:
    Dilution error
    Weighing error
    Standard may degrade (standard area) when compare to previous result

  • @nagaraj5948
    @nagaraj5948 2 роки тому

    sir in hypothesis Re-test y wrong stock preparation included i think if weight wrong taken means phase-1a only we came to know right

  • @sunilmangate3580
    @sunilmangate3580 2 роки тому +1

    Thanks so much

  • @seetharamuluchinthaguntla8698

    Sir , How to investigate hold time OOS

  • @maheshgupta564
    @maheshgupta564 2 місяці тому

    Pl explain sir II and III bhase

  • @Seshu03
    @Seshu03 Рік тому +1

    Hi, Have done phase II and III?

  • @Chikuonline
    @Chikuonline Рік тому +1

    Please make a video on preliminary impact assessment during investigation

  • @swha0805
    @swha0805 5 місяців тому

    thank you

  • @sameer_shindeshinde3674
    @sameer_shindeshinde3674 Рік тому

    How wavelength is obvious error, if wavelength wrong is used for analysis, area of standard can not match with previous analysis then why we proceed further,
    If we proceed further then oos can not happen 99% because wavelength is same through out analysis also during validation we perform plus minus wavelength robustness parameter

    • @mustaqeemshaikh5818
      @mustaqeemshaikh5818 2 місяці тому

      Dear friend,
      It means whether method is used correct or not

  • @PrashantKumar-vc1ho
    @PrashantKumar-vc1ho 3 місяці тому

    nice

  • @johnbabu8708
    @johnbabu8708 Рік тому

    We are unable to join in your group because of your group is full

  • @LisaHernandez-b4g
    @LisaHernandez-b4g 2 місяці тому

    Schamberger Groves