MEDIA FILL VALIDATION IN HINDI, MEDIA FILL VALIDATION IN PHARMA, MEDIA FILL SIMULATION IN PHARMA.

Поділитися
Вставка
  • Опубліковано 18 січ 2021
  • Hello friends this video contains the entire information regarding media fill validation, how to perform media fill, when to perform, what were the technical POINTS ts to be monitor, etc. Etc. Media fill is another important topic in pharma industry and plays an Critical role in Aseptic formulation. This video will tell us what is media fill, how to perform, and what are the important factors to b in mind while performing media fill.
  • Наука та технологія

КОМЕНТАРІ • 118

  • @feelmagnetic3176
    @feelmagnetic3176 3 роки тому +1

    Very gud information about media fill.....thnks

  • @Learnwithsimon27
    @Learnwithsimon27 Рік тому +1

    Amazing explanation🎉

  • @arvindkumaryadav2753
    @arvindkumaryadav2753 2 роки тому +1

    Thank sir for guiding in easy way.

  • @ghanshyam4765
    @ghanshyam4765 3 роки тому +1

    Very nice and informative video...
    Keep it up sir

  • @tanujatripathi4276
    @tanujatripathi4276 2 роки тому +1

    Nice and informative vedio

  • @James0010ful
    @James0010ful 3 роки тому +1

    Thanks for your valuable informative video

  • @nitishpandey5010
    @nitishpandey5010 2 роки тому +1

    Aapka hindi me samjhana bht accha lgta h sir💐🌹🌹🌹🌹

  • @narsimhareddykallu8289
    @narsimhareddykallu8289 Рік тому +1

    Excellent sir

  • @riddhijoshi5600
    @riddhijoshi5600 3 місяці тому +1

    Sir you explained very well. Thank you. Please make video on autoclave and SIP validation.

    • @loveforpharma934
      @loveforpharma934  3 місяці тому +1

      Thanks dear for liking my video, very soon I will make video on said topics, till then please subscribe my channel and share my videos to your known ones and friends.

  • @Kalpana0311
    @Kalpana0311 3 роки тому +1

    Intresting information sir 🙏

  • @ranjeetnagarkoti3274
    @ranjeetnagarkoti3274 3 роки тому +1

    Really helpful video. Thanx a lot 👏

  • @sachinsuryawanshi7149
    @sachinsuryawanshi7149 2 роки тому +1

    Best video

  • @ajaydhiman4381
    @ajaydhiman4381 3 роки тому +1

    Thanks for the amazing information sir

  • @redride6517
    @redride6517 2 роки тому

    Fantastic, appreciate

  • @barneyzpgamer2415
    @barneyzpgamer2415 2 роки тому

    excellent

  • @nishakaushik7098
    @nishakaushik7098 3 роки тому +1

    Very nice information

  • @amolthorat9434
    @amolthorat9434 2 роки тому +1

    Thank you so very much sir...

  • @tanujatripathi4276
    @tanujatripathi4276 2 роки тому +1

    Hi please/ make a vedio for documentation process and trending of Interventions ( liq/lyo/cartridge/ pfs)..Technical documentation

  • @pritamhalder2119
    @pritamhalder2119 3 роки тому

    Thank you for information 🙏

  • @thisisarpitjain9608
    @thisisarpitjain9608 2 роки тому +1

    Pls sir make a lecture on GEP (Good Engineering Practice)

  • @kailashtonk8342
    @kailashtonk8342 3 роки тому +1

    Thanks for information

  • @prashantparihar929
    @prashantparihar929 2 роки тому +1

    Sir 1st time aseptic area validation PR vedioes banao

  • @knowledgerise9552
    @knowledgerise9552 2 роки тому +1

    Sir plz make the videos on parenteral machines. Sir Why u stopped making the videos.

  • @microbiologistnishantgupta
    @microbiologistnishantgupta 2 роки тому +1

    Thats very useful

  • @dattadawande4975
    @dattadawande4975 3 роки тому +1

    Very good sir

  • @bainschannel1533
    @bainschannel1533 2 роки тому +1

    Tnxx sir

  • @vipinsagar7563
    @vipinsagar7563 2 роки тому +1

    Sir sterility failure pe bhi ek video bna dijiye.

  • @rakeshkumarsingh2573
    @rakeshkumarsingh2573 3 роки тому +1

    Nice sir

  • @shivrajwadekar9807
    @shivrajwadekar9807 5 місяців тому +1

    Thanx

  • @shubhamdogra4831
    @shubhamdogra4831 3 роки тому +1

    Sir tubular glass vial or molded glass vial m difference ki video banana hindi m.

  • @MANOJ-Galary
    @MANOJ-Galary 3 роки тому +3

    What's difference between 1 vial failure out of 10000 and more than 10000?
    In both cases we have to investigate, no need to repeat media fill, correct?

    • @loveforpharma934
      @loveforpharma934  3 роки тому

      no in one vial you may repeat media fill in d basis if investigation, and in case of more then 2 vials u must repeat media fill

  • @bainschannel1533
    @bainschannel1533 2 роки тому

    Sir GRANULETION Equipments pr bhi video bnaooo

  • @praveenkotekar5858
    @praveenkotekar5858 3 роки тому +1

    Sir thank you

  • @jankeemistri9054
    @jankeemistri9054 3 роки тому +1

    Can we autoclave the media being used for media fill? Why filtration sterilization is preferred?

    • @loveforpharma934
      @loveforpharma934  3 роки тому

      before going for media fill u must autoclave ur media, otherwise u cant define the contamination while filling.

  • @ManojSharma-de8ik
    @ManojSharma-de8ik 2 роки тому

    Sir during media fill, prepared media can be hold in difrent vessel , other than container used for preparation. Wt abt bungs, bung hold kaise karna hai, bung processing me, ya vessel me

    • @loveforpharma934
      @loveforpharma934  2 роки тому

      you can hold ur media or bung if it is part of your routine process

  • @premraj-sp8bm
    @premraj-sp8bm Рік тому +1

    Thanks sir mixing aur filling pe video ban do please

  • @kumargaurav-pt6cv
    @kumargaurav-pt6cv 3 роки тому +1

    Which guidelines use for media fill(aseptic simulation)

  • @nileshraval2585
    @nileshraval2585 2 роки тому

    Sir, prepare video of Autoclave validation

  • @sunnykumar-gf1ov
    @sunnykumar-gf1ov 2 роки тому +1

    intervention pe video banana sir g

  • @nikhiltandel3063
    @nikhiltandel3063 Рік тому +2

    Which guidelines reference for media fill

  • @ainars1205
    @ainars1205 2 роки тому +1

    Does it means that after media fill test each vial of 5000 units needs to be tested for sterility according to pharmacopoeia sterile test?

    • @loveforpharma934
      @loveforpharma934  2 роки тому

      no dear each n every vial will go under visual unspection because if there would any contamination it would get terbid

    • @ainars1205
      @ainars1205 2 роки тому

      @@loveforpharma934 If it is glass transpared vial then everything is clear, but if product is packed in 500 ml PE not transparent bottles what then? How to check it visual?

  • @VijaySingh-zs9wo
    @VijaySingh-zs9wo 2 роки тому

    Sir media fill anaerobic bacteria ke liye kese perform kre??

  • @Jnabji-jb7je
    @Jnabji-jb7je 2 роки тому

    What about dry powder injection

  • @MANOJ-Galary
    @MANOJ-Galary 3 роки тому

    1 vial failure out of 5000, we have to do 3 run media or 1 batch is sufficient?

    • @loveforpharma934
      @loveforpharma934  2 роки тому

      1 batch us sufficient but ingestion required for failure

  • @aasusharma1439
    @aasusharma1439 Рік тому

    Sir, Which guideline is used for cleaning and process validation

  • @nehachouhan4797
    @nehachouhan4797 2 роки тому

    Hlo sir please mujhe btaiye ki 3 phase me kya scdm ko hi use kiya jata h ek hi batch k

  • @aryanpant982
    @aryanpant982 3 роки тому +1

    there is no defined limit for sterile preparation .because sterile itself means that it should be free from all the forms of life whether it is vegetative or sporogenic...

    • @loveforpharma934
      @loveforpharma934  3 роки тому

      yes offcource there are microbial limits for sterile preparations

  • @FactSawari
    @FactSawari 3 роки тому

    Sir PPA ke bare me bhi jhyada se jhyada batayiye

  • @siddharthzala2652
    @siddharthzala2652 3 роки тому

    🙏🙏🙏

    • @satishsharma-oi5pr
      @satishsharma-oi5pr 3 роки тому

      Why use of compressed air in media fill?

    • @siddharthzala2652
      @siddharthzala2652 3 роки тому

      @@satishsharma-oi5pr I don't know sir

    • @loveforpharma934
      @loveforpharma934  3 роки тому

      nk dear we dont use compressed air in media fill, of which stage u r talking about

  • @rishabhahlawat9933
    @rishabhahlawat9933 3 роки тому +1

    How calculator how many settle plate in an area validation

  • @saini7190
    @saini7190 2 роки тому

    Why you stopped making more content? It's informative but I can see you stopped like a year ago.

    • @loveforpharma934
      @loveforpharma934  2 роки тому +1

      yes dear actually i was busy in some other project, but very soon i will start to make more videos.Thanks

  • @ramanpurohit7922
    @ramanpurohit7922 Рік тому +1

    Autoclave validation k bare m

  • @praveenkotekar5858
    @praveenkotekar5858 3 роки тому +1

    Sir 21 CFR ka video bi banayi na

  • @rabindranayak6899
    @rabindranayak6899 Рік тому +1

    Media fill following which guidelines

  • @bhagvanbachhav779
    @bhagvanbachhav779 3 роки тому

    How to destoy media filled vial or ampoules sir

    • @loveforpharma934
      @loveforpharma934  3 роки тому

      first of all nutralize them by autoclave then send it to ETP

  • @Jnabji-jb7je
    @Jnabji-jb7je 2 роки тому

    Which media is filled in dry powder

  • @saivineeth9427
    @saivineeth9427 3 роки тому +1

    Sir why soyabean is only used....? Can u say

    • @loveforpharma934
      @loveforpharma934  3 роки тому

      yes because it is favourable for wide range of microbes

  • @MANOJ-Galary
    @MANOJ-Galary 3 роки тому

    Plz brief about breacketing approach, to avoid multiple runs

    • @Myvideos382
      @Myvideos382 2 роки тому

      Trainer doesn't have depth knowledge of sterile formulation...
      Anyway he cover many things

  • @Mr0000DJ0000
    @Mr0000DJ0000 3 роки тому

    Sir, ICH and Startified Sampling define

  • @nerajsharma4758
    @nerajsharma4758 Рік тому

    Sir Interpretation of data not clear understanding.. please help me

  • @lakshmisai1315
    @lakshmisai1315 2 роки тому

    Sir plz provide English subtitles

  • @afuntime7296
    @afuntime7296 Рік тому

    Sir 60% fill ka toda detail me smjhaao or opthalmic media fill k tym inwards or upward dono condition me dekha jata h kya ?

    • @loveforpharma934
      @loveforpharma934  Рік тому

      60 % isliye taki container ko ulta karke rakhen to media pure container ko acquire kar sake. yes agar container ko kar sakte hain to karna chahiye

  • @amolpatil1748
    @amolpatil1748 3 роки тому +1

    Why 3% media used