Madam 1 video column to column distance kaise nikalte hai autocad me wo sikha dijye and column and beam k width kaise reduce krte hai 300mm se 200mm wo v bataye madam
Great video! I want to add that, beam connected to beam reduces the overall ductility of structure. As the joint connections experience maximum shear and moment during an earthquake, it is always advised to support the beams by columns for safe transfer of forces.
How can be hidden beam dimensions same as tiger beam . As you said hidden bean depth will be less and will be hidden with slab compared to the other primary and secondary beams. Doubt .please clear
Mam 1st ty u for sharing Ur knowledge... 1 beam detailing is missing in this video... Near b6 beam there is a 1 simply supported beam......if may I correct?
Hi Omi, No beam is missing, Secondary beams are simply supported or shear connected, like B 5. Go through the video properly I hope you will understand which beams are primary & which are secondary beams.
Thank you mam, I have 2 doubts, that why have you provided beam in staircase area as slab will not be provided there and also what is the purpose of hidden beam and where is it provided usually? Pease reply , Thank You
Hidden beam is provided because it gives better aesthetic interior appearance as the Depth of hidden beam is same as depth of slab.It is economical as it saves cost of materials,formwork and labor.staircase room you can't provide beam, that is provided mistakenly on drawing.
Ma'am Good Morning! Very nice video! Thank you very much. But I am confuse whether two B5s (Two of the Beam 5) are hidden beams or not because they are not connected to columns in one side. They look like same as B16 (10"x4").
No B5(10"x10") is not hidden beam. B5 is going above wall. But B16(10"x4") is hidden beam because as there is no wall, if we provide B16 as (10"x10") means width 10" & depth 10" then we can see the depth of beam hanging on ceiling surface. But you can provide (10"x10") beam there instead of hidden if you want. But it may look little bit odd. So hidden beam is provided within the depth of supporting slab. so Depth of hidden beam is same as Depth of slab. So as there is no wall so B16 is provided as hidden beam so we can't see the depth because hidden beam is going within the roof slab. But B5 is not hidden beam because wall is available there. B5 is going above wall so we can't see the beam completely.so this is (10"x10") beam. And one more thing you are asking that B5 & B16 are not connected to columns in one side. So it's not necessary that beam should be always connected column to column only. Beam may be supported on other beam or may be supported by columns forming an integral part of the frame. I have told all these elaborately in the video. You should go through the video thoroughly so that you can understand. Thanks for watching
how to scale breadth and depth of a beam I mean to say that I want to scale any object according to my size suppose depth of a beam is 950mm abd breadth of beam is 600mm I wanted to scale it 230 x 750 mm how can I scale?
Building height is generally taken 10 feet and 6 inches from plinth level. Go through this video. The detail explanation you will find. ua-cam.com/video/AB2R3B8FcHs/v-deo.html
Stub column. Red columns are Stub Columns. Stub columns are located below ground level to avoid long spans of grade beams and in places where the soil condition is not enough strong for load bearing structure and not too less strong for framed structure. Stub columns are provided in such places to minimize the construction cost.
PlayList : Complete Building Drawing in AutoCAD || Building #2
ua-cam.com/play/PLGstbEuPUsWXn3Q9wZQhm8gPQ5RwtptAV.html
CIVIL Engineering Tutorials compounding drawing mam
thank you mam
interior designing tutorial please
Madam 1 video column to column distance kaise nikalte hai autocad me wo sikha dijye and column and beam k width kaise reduce krte hai 300mm se 200mm wo v bataye madam
Mam please provide dwg file...
Please
The best beam layout tutorial.Than you for this.
C
Great Excellent Informed video ❤❤❤❤❤❤❤❤
Thanks for watching
Great video! I want to add that, beam connected to beam reduces the overall ductility of structure. As the joint connections experience maximum shear and moment during an earthquake, it is always advised to support the beams by columns for safe transfer of forces.
Thanks for watching. Very good observation and point to be noted.
Your video really helps especially to those who are just beginners like me. Thank you. Keep it up!
Glad to hear that!
Thanks so much maam, for explaining easily.very nice.
welcome
Thanks so much mam, your explaining very easily. very very nice.
Welcome 🎉 Imran
nice
So nice
Mam. Thank you so much for sharing useful information. Thanks a lot
Most Welcome
Nice job n thanks for the information
Thanks a lot Sharieff
Really very great
Thankuy mam
Most welcome
Thanks
Welcome
It's good madam Tq.
Thanks a lot Harish
thank you mam
Welcome
Thank you very much it is so helpful and clearly but my suggestion goes like this you can simplify the way of fully downloading all the package.
Thanks for the tip
Loved ur video
Thanks. Please go through all the other videos in he channel and provide your valuable feed backs.
Thank u didi very helpful vdo :)
Welcome
Well done maam
Thank you Yash
Thanq mam
I love YOU
great
Thanks
nice ☺
How can be hidden beam dimensions same as tiger beam . As you said hidden bean depth will be less and will be hidden with slab compared to the other primary and secondary beams. Doubt .please clear
Hidden beam size 10"×4", depth of hidden beam is same as thickness of roof slab.
Cute Voice 😍❤️
HII MADAM
you missed one beam, betweem the "B6 AND B9". thankyou madam for your youtube channel. I want help from you.
Hi, madam how to number of floor on plot kindly makes vlogs on it
Mam shouldn't there be another beam in balcony connecting 2 cantilever beams to form the frame
Mam 1st ty u for sharing Ur knowledge...
1 beam detailing is missing in this video... Near b6 beam there is a 1 simply supported beam......if may I correct?
Hi Omi,
No beam is missing, Secondary beams are simply supported or shear connected, like B 5. Go through the video properly I hope you will understand which beams are primary & which are secondary beams.
Thank you mam, I have 2 doubts, that why have you provided beam in staircase area as slab will not be provided there and also what is the purpose of hidden beam and where is it provided usually? Pease reply , Thank You
Hidden beam is provided because it gives better aesthetic interior appearance as the Depth of hidden beam is same as depth of slab.It is economical as it saves cost of materials,formwork and labor.staircase room you can't provide beam, that is provided mistakenly on drawing.
@@CIVILEngineeringTutorials thank you mam for fast reply
@@CIVILEngineeringTutorials please make a video on electrical layout and plumbing layout
Since column are not in grid how much it is important...?
Mam please provide plinth beam layout plan.
Sure Siva. It will be provided soon.
Ma'am Good Morning! Very nice video! Thank you very much. But I am confuse whether two B5s (Two of the Beam 5) are hidden beams or not because they are not connected to columns in one side. They look like same as B16 (10"x4").
No B5(10"x10") is not hidden beam. B5 is going above wall. But B16(10"x4") is hidden beam because as there is no wall, if we provide B16 as (10"x10") means width 10" & depth 10" then we can see the depth of beam hanging on ceiling surface. But you can provide (10"x10") beam there instead of hidden if you want. But it may look little bit odd.
So hidden beam is provided within the depth of supporting slab. so Depth of hidden beam is same as Depth of slab. So as there is no wall so B16 is provided as hidden beam so we can't see the depth because hidden beam is going within the roof slab.
But B5 is not hidden beam because wall is available there. B5 is going above wall so we can't see the beam completely.so this is (10"x10") beam.
And one more thing you are asking that B5 & B16 are not connected to columns in one side.
So it's not necessary that beam should be always connected column to column only. Beam may be supported on other beam or may be supported by columns forming an integral part of the frame. I have told all these elaborately in the video. You should go through the video thoroughly so that you can understand.
Thanks for watching
Thank you very very much ma´am. Thanks a lot for the quick response. Now I am clear about the positioning of the hidden beams.
Can you provide the dwg or pdf file for practice
Yes. Please click on the super thanks button available veliw video and send an email to civilengtutorials@gmail.com
Hello
Can I get this drawing file ?
I want to practice .
how to scale breadth and depth of a beam I mean to say that I want to scale any object according to my size suppose depth of a beam is 950mm abd breadth of beam is 600mm I wanted to scale it 230 x 750 mm how can I scale?
Mam
Medam create the electrical plan and swerage plan .i dont know how we can draw this plans
What dimension you take for column?
10"x10"
mam please tell me how to take building height from the elevatio
Building height is generally taken 10 feet and 6 inches from plinth level. Go through this video. The detail explanation you will find. ua-cam.com/video/AB2R3B8FcHs/v-deo.html
Mam how to draw polyline in z axis
Will upload soon
AutoCAD #27 - POLYLINE Command in AutoCAD - PART 1 (Arc|Close|Halfwidth|Length|Undo|Width)
ua-cam.com/video/lQ6BRwJntUc/v-deo.html
AutoCAD #28 - POLYLINE Command in AutoCAD - PART 2 (Angle|Center|Line|Radius|Second Pt|Undo|Width)
ua-cam.com/video/R8qkk8i2X-U/v-deo.html
Please attach Auto cad dwg files below video
Hi Venkata, Thanks for watching.
Please share your emailid. Only pdf files will be shared.
nareshmannam1995@gmail.com
Sent.
Where is stub column
ua-cam.com/video/9Vc29g5sabk/v-deo.html
Medom hiden beam slab me kaha provide kiya jata ha
Ek baar video ache se dekh lo. Usme detail me bataya gaya hai.
Mam u have forgotten b6 and b9 toilet to put beam
Mam what is staff column
Stub column.
Red columns are Stub Columns. Stub columns are located below ground level to avoid long spans of grade beams and in places where the soil condition is not enough strong for load bearing structure and not too less strong for framed structure. Stub columns are provided in such places to minimize the construction cost.
Thanx
I want compounding drawing
Hmm. will provide.
9
Plz medom y tell me
Bhawdi phele bolna seekh le
Thank you mam
welcome