Sulfur recovery unit " process description" SRU

Поділитися
Вставка
  • Опубліковано 3 жов 2024
  • SRU, sulfur recovery from hydrogen sulfide,sulfur recovery.

КОМЕНТАРІ • 54

  • @adityavardhanmalla4653
    @adityavardhanmalla4653 2 роки тому +5

    Elaborative explanation and covered most of the topic.

  • @miniondusty3251
    @miniondusty3251 2 роки тому +2

    Thank you so much for your elaboration this helps me for the last min preparation for project work.

  • @amazigheism
    @amazigheism 3 місяці тому

    My advise to you to request help from someone for making your video.
    For example for Reactions explanation while you explain, the reaction formula not showing

  • @abs111
    @abs111 3 дні тому

    How to take sample Acid gas, quench column and liquid sulfur?

  • @sarfarazhussain7752
    @sarfarazhussain7752 2 роки тому +1

    Good explanation 👍👍

  • @muhammadadeel2745
    @muhammadadeel2745 4 місяці тому

    What is the recommended air ratio to get elemental sulfur

  • @MrHabib092
    @MrHabib092 2 роки тому +2

    I am Chemical engineer I worked in SRU plant

    • @narendralodhi17
      @narendralodhi17 2 роки тому

      Hi. Which type of pump is used for Liquid Sulfur loading arms.
      Is the Pump having 2 separate discharge line for liquid unloading and solid unloading of sulfur.

    • @chemicaldiary8412
      @chemicaldiary8412  2 роки тому +2

      steam jacketed centrifugal pumps are used
      in one company we used submersible pump for transfer
      and another branch we have vertical and horizontal pump which are not submersible
      but both pumps will always have continuous steam to avoid solidification of sulfur.
      pump will have one discharge line and one mcf line for circulation to keep pump always in hot condition with flow of steam
      for solid prilling tower conveyor rakes are used to transfer solid sulfur as pump cannot pump solid sulfur solid sulfur is hard as 🪨 stone.
      molten sulfur will be load in tanker from top lid of tanker arm is withdrawn from top to the tanker
      sulfur tankers also steam jacketed

    • @narendralodhi17
      @narendralodhi17 2 роки тому

      @@chemicaldiary8412 in which Refinery you are working ?

    • @narendralodhi17
      @narendralodhi17 2 роки тому

      Which type of flow meter is installed to calculate liquid Sulfur flow to loading arms.

    • @chemicaldiary8412
      @chemicaldiary8412  2 роки тому

      endress hussar flow meter ,insertion type
      we used 1.8 specific gravity
      molter sulfur flow rate is 16m3/hr then how much will be loaded can be determined by 16*1.8= 24 ton would be weight of sulfur tanker loaded

  • @gajatexmdu
    @gajatexmdu 3 роки тому +1

    Good effort

  • @-HemanthKumar-ni8jh
    @-HemanthKumar-ni8jh Місяць тому

    Can you share pdf

  • @adityadas1462
    @adityadas1462 5 місяців тому

    2min ru equipment details

  • @ssaihtc8922
    @ssaihtc8922 2 роки тому +2

    Thanks and crystal clear explanation 🙂😃😃

  • @mramprasad96
    @mramprasad96 3 роки тому +1

    Sir, does the sulphur collecting pit temperature is maintained using external source because the liquid sulphur melting is 110 C

    • @chemicaldiary8412
      @chemicaldiary8412  3 роки тому

      steam is used to maintain the temperature
      check my other vedio for further information

  • @MOhammedAli-ur7sp
    @MOhammedAli-ur7sp Рік тому

    Can you arrange TGTU Also with Temperature same like this units. So we will understand TGTU Also.

  • @yousif504
    @yousif504 2 роки тому +1

    Thanks. It is very informative for non process engineers

  • @Chennaikarthick
    @Chennaikarthick 2 роки тому +1

    Very useful and I subscribed 👍

  • @intesarsiddiqui
    @intesarsiddiqui 3 роки тому +1

    Superb Explanation for the Beginners

  • @amazingfacts3885
    @amazingfacts3885 3 роки тому

    What's Direct and indirect method??? Can you explain in briefly??

    • @chemicaldiary8412
      @chemicaldiary8412  3 роки тому

      in some sru process direct cooling takes place in case of process gas have impurities wheras if there is no impurities then indirect cooling takes places with aid of different ex changer where as for direct method dynawaves are used

  • @engineernaeem5970
    @engineernaeem5970 Рік тому

    Hello sir
    Sir mujy sulfur recovery from H2S pa project mila h please Kuch data send KR Dy es topic KY releated

  • @shaikahamad480
    @shaikahamad480 3 роки тому

    Please do a video on lpg recovery from natural gas

  • @homeaway0
    @homeaway0 4 роки тому

    Where does the water go

  • @adityadas1462
    @adityadas1462 5 місяців тому

    6 min ru process start

  • @jeyansamudraraja6120
    @jeyansamudraraja6120 3 роки тому

    DEAR FRIEND
    I HAVE ONE DOUBT TEMPERATURE 1300 TO 1450 FOR WHAT

    • @chemicaldiary8412
      @chemicaldiary8412  3 роки тому

      we must have furnace temperature more than auto ignition of hydrogen sulfide
      u can burn at 600 degree also it is advisable to go for 1000 degree different vender different variable

  • @AjmalKhan-jh3yd
    @AjmalKhan-jh3yd 2 роки тому

    hi bro, i worked in gas processing unit and i need the PFD of all SRU 's. Your explanation is elaborative and please cover the topic of analyser for SRU and TGT

  • @lovelyhart2844
    @lovelyhart2844 4 роки тому +1

    Super bro

  • @mohamedmostafamohamed1557
    @mohamedmostafamohamed1557 3 роки тому

    Dear, How we control temp in thermal reactor please ???

    • @chemicaldiary8412
      @chemicaldiary8412  2 роки тому

      We inject LP steam to reduce the temperature of furnace

  • @abrehmanlashari2831
    @abrehmanlashari2831 3 роки тому

    Great Explanation 👍

  • @dewanshkaushik4817
    @dewanshkaushik4817 4 роки тому

    Great Explanation sir