Alignment from object Error in Civil 3d | Wrong Location of Alignment from Polyline

Поділитися
Вставка
  • Опубліковано 2 гру 2024

КОМЕНТАРІ • 18

  • @Goldenhill708
    @Goldenhill708 7 годин тому +1

    Thank you very much sir, may Allah reward you with more honor, Jazak Allah Khair.

  • @kaleemabbas9668
    @kaleemabbas9668 10 годин тому +1

    Mashaa ALLAH sir good work

  • @ibrahimsabir6547
    @ibrahimsabir6547 День тому +1

    MA SHA ALLAH AND JZAKALLAH

  • @AnilKumar-hk5fo
    @AnilKumar-hk5fo День тому +1

    Nicely explained Sir,🙏

  • @attaullahkhan9154
    @attaullahkhan9154 День тому +1

    very nice trick Sir jazakallah khair

  • @shahabali2549
    @shahabali2549 День тому +1

    Great knowledge sir❣️

  • @associateengineerhabibulha2398
    @associateengineerhabibulha2398 День тому +1

    Dear Respected Sir I have Dwg there is corridor & surface actually it is for water channel trapezoidal shape i need 04 point 02 down and 02 from upper level for each 5 meters

    • @naseerbhatti177
      @naseerbhatti177  День тому

      To assign top and bottom labels for a ditch in civil 3D cross-sections, you should first assign Point Codes to the relevant points in the ditch or channel assembly. If you are looking to generate a point report at fixed intervals, you can achieve this by utilizing the Corridor Section Report found under the Toolbox in Corridor Reports. For further assistance, I am sharing some video links that you may find useful. Following the links provided below will help you obtain the desired data.
      Markpoint in civil 3d Assembly
      ua-cam.com/video/4lTMmGW5su0/v-deo.htmlsi=z_ykB3kU7BddZ1Gc
      Codset Style to Civil 3d Assebmly
      ua-cam.com/video/BgC7bl17peg/v-deo.html&pp=gAQBiAQB
      Corridor Point Report & Error Solution
      ua-cam.com/video/J0GPotxTMEQ/v-deo.html&pp=ygUpY29ycmlkb3IgcG9pbnQgcmVwb3J0IGluIGNpdmlsIDNkIHByb2JsZW0%3D
      Toe and Catch Point in Civil 3d
      ua-cam.com/video/zFWPHQAWoBE/v-deo.html&pp=ygUfVG9lIGFuZCBjYXRjaCBwb2ludCBpbiBjaXZpbCAzZA%3D%3D

    • @associateengineerhabibulha2398
      @associateengineerhabibulha2398 День тому

      @naseerbhatti177
      Sir can you make short video form this dwg

  • @mubashirahmed3376
    @mubashirahmed3376 День тому +1

    Hello sir Sir I am facing this issue when I create corridor at the start and end chainage of my corridor this vertical line coming and when I create cross sections 00 and end station cross sections are made with almost 50 m height

    • @naseerbhatti177
      @naseerbhatti177  День тому

      Hello dear, I have observed that the start and end stations of your design profile appear to be shorter compared to your OGL profile or alignment length. It is important to ensure that the design profile length aligns with the alignment length.
      If there are specific conditions that necessitate a shorter design profile, please adjust the start and end stations of your corridor to match the profile's start and end stations. This should resolve the issue at hand.

    • @mubashirahmed3376
      @mubashirahmed3376 День тому +1

      ❤ thanks sir for your cooperation