Fronus Platinum Series Feed Back (Conclusions)
Вставка
- Опубліковано 15 бер 2023
- Technical Guidance
. . . . . .❤ ❤ آن لائن Paid ہیلپ سروس
سولر سسٹم / الیکٹرونکس کا ٹیکنیکل مسلہء حل کروانے کیلئے ۔💯
Please First Pay My Service Charges 1000 Rupees to Solve Your Problem.
03006715530 only WhatsApp Please Don't Call me
Mahmood Azeem
Msc Fibre Technologist
Electronics Diploma holder
/ @technicalguidance
❤🇵🇰❤
Dear Friends: I have a Degree of Msc. Fibre Technology from the University of Agriculture Faisalabad (Uaf) ❤
#TechnicalGuidance
#MahmoodAzeem
فالو مائی فیس بک پیج :
Follow My Facebook Page :
profile.php?...
E-Mail Address:
mahmoodfibre@yahoo.com
@Technical Guidance
@Mahmood Azeem @MahmoodAzeem
#technicalguidance
یہ میرے سیکنڈ یوٹیوب چینل کا لنک ھے ۔ سبسکرائب👍 کر لیں ۔❤ 🇵🇰
Mahmood Azeem
/ @technicalguidance2 💯 - Наука та технологія
👍 true picture presented.
ماشاءاللہ بہت خوب مقبول اللہ تعالیٰ آپ کو کامیاب کرے آمین ثم آمین
Chota inverters ka charge controller chota hotha hai aur wo bari tublar batteries ko charge karne ka liye nhi hota is liye choti batteries in inverters ka sath acha work karti hai
Good piyaray bhai
Very good
Thanks bahi
Aaj pta chala Battery trip q krti hai fronus platinium pv7200 per. So it means it is full charged. Its true charging stop nahe hoti. Me battery off kr k. Wapda per reverse metering krta hn.
- Fan slow aur fast Solar ki electricity per hota hai. 1000watts per bhot slow fan chalta, 2,000 say uper kafi teez hojata
- Agar 4000 watter Solar say bijli paida horahe hai. aur home 500 watts use horahe. To is k mutabiq reverse metering per ( 4,000-500 = 3,500watts) honi chahiye. Laken aisa nahe hota. 2,800 k aas pass reverse hoti hai. ( 6-700watts ) bijli kahan jati pta nahe.
- PV 7200 per 02 temperature error ata hai. Wapda bnd kr k inverter restart krna parhta hai. jo aik bara masla hai. Is ka solution dono side say safai krni parhti. 5-10 min lgtay. easy kaam hai. Laken har 2 haftay.
- Agar cooling ka issue ho to 45degree per inverter bnd hojata. 02 error. Safai k bad 48 49 tk be jata hai. Air intake better hojati hai. ( every week safai krni parhti )
- Temperature error 02 tb hota hai jb 3,000watts say ziada bijli paida hoti.
Solar panel lgai huay months say ziada hogya meter ko 10 din he huay.
- Agar Wapda chali jati. Solar auto on/off hota bar bar. Us ka solution no 1 yeh hai. battery ko on rakho ta k load sharing ho battey k sath. Phir bad me battery bnd krdo to koi masla nahe. Solution 2 yeh hai k load km kr do shuru me. Load ko UPS per shift kro 4 5 second k liye aur fir full ghar k load per jaldi say shift kr do. Phir be masla hai to FRIDGE off kr do. shuru me wo ziada leta hai.
- Agar wapda be nahe, Aur raat ko waqt hai solar be nahe, To battery per pe nahe chalraha q k 3 4 gantay full load chalraha. Is k bad app ghar k load ko UPS per shift kr do jo k 300 watts k aas pass hoga. low battery per be 40-60 min chaljai ga.
- SBU [ SOLAR, BATTERY, WAPDA ]
- SUB [ SOLAR,WAPDA,BATTERY ]
- NO 16 per 0S0 kr do Ta k battery sirf solar per he charge ho subah k waqt. waisay raat k waqt be battery charge hoti hai wapda per. Phir bill ziada ata.
jo log 400- 500 unit instemal krtain hai wo 6 kv na lagain 8kv lga lain .. Meter 0 hojaiga. 1time investment hai To sahi tareeqay say kray. Thori see kanjoosi say kafi nuqsaan be hosakhta hai.
- 545 12panel ( 545*12 =6,540 ) produces 4700watts max in islamabad. ( 71%) but it can produce more. If city is in KPK & weather is good.
- Pta nahe Sardio me kitna produce kray ga expectation km he hai.
- Ip65 inverter kharido wo kafi bethr rahe ga q k pv7200 per temperature error ata. Us ki life be ziada hoge.
- Agar solar 1,000 watt bnaraha hai. ghar me 500 watts istemal horahe hai Baki 500 zaya jati hai reverse metering start nahe hoti. Agar ho be gaye to 100 watts k ass pass hoge 400 watts zaya jain gay. solution yehi hai battery na lgao aur solar system bara lgwao.
- Aur akhir me yehi kaho ga k Ground floor per inverter aur battery rakho aur proper research kr k. Agar paisay km hai to battery k bgair thora bara system lgwalo. Ta k bill 0 hosakhay.
Good work
بہت شکریہ آپ لوگوں کی رہنمائی کر رہے ہیں
Ap kia recommend karte haan Fronus pv2200 or Ziewnic aim 1.5 VM3 ?
inverex best inverter pakistan ma pv2500 ak tan ka ac be chalta ha our baki ghar ka sara load be
Aoa bhai iska infenion reborn 1.6 kw ka jo naya model aya hai uski performance p aik achi si video bnaen kahin bahir se casing change kr k company ne dubara wohi board laga k toh nhi de dya.
PV2200, main issue is PV shortage.
Fronus 1.2 use KR RHA hon one year see good result hy
bhai primax venus 2000 1.6 kv inverter kesa ha plz guide kardo
10kv inverter may Konsa brand acha hain
Jo log solar aford nai kar saktay simple mehran battery lain charger auto cutt off wala or 1 inverter 12v to 220v wala 2000watt jiski asal power 600watt ha behtreen ha
رہنمائی کرنے کا شکریہ
Bhai mera pv 2200 har wqt 0.7 ampere wapda use krta rehta he chahy koi chez use kren ya na kren. Is ka koi hal btaen k .
inverex ke output 3000 ha 2500 watt pora data ha veri good inverter thora mehngha zaroor ha
Mashahlla ap ka kam bohat hacha hai
❤❤❤
4 panel agar is k sath 580w k laga den tubkia sada frij chala de ga?
Bhai Sab se acha inverter Kon sa hai??
Veyron 2.5 ki actual output kitni ho gi?
Bhai 1kva ya 1.2 kva Mai best Inverter bta dain
Dont buy Firaunus .....
Power factor k mamle me to sab hi jhoote hein ke 1 hota hai ......it can never be 1 ....
Kachra inverter
السلام علیکم سر میری ریکویسٹ ہے کہ زیونک 1.5ایک ہزار واٹ کے مطلق بتائیں اگر پانچ سو واٹ کی ایک پکیٹ لگائیں تو کون سی بیٹری استعمال کریں اور اگر پانچ سو واٹ کی دو پلیٹس لگائیں تو کون سی بیٹری استعمال کیں پلیر۔
Pv3200 me bhi yahi fault aa rahe hain
Salam bahi...fronus 1.5kw kaysa hay...?
PV 3200 Kaisa inverter Hy
Bai PV 3200 PAINUM MA 003 soft ware ha pv volt drop issu ha kia kray
Sofware upgrade karwaien
Sir 3 solar 250 watt k panael k liya k best inverter kun saa haa
koi nahe
Fronus company k inverter kabi mat lena is mai bhout masley masial hai
agr may 2000/1600 kro tu power factor 1.25 banta hai 😁
dabardst chal raha hai mery ghr many high load bhi check kia sahi kam krta hai
Ha me be chal rha ho ok ha Bhai 5 ganty light nahe ho ta ha ok ha mara wala
Bhai apka pv2200 hai or kesa chl rha hai?
150 watts load k sath agr aik aam fridge chlani ho to kon sa inverter acha rahe ga?
Fridge shuru me ziada bijli khenchta hai.. 3kv minimun lo. 1.2 1.5kv inverter ki value nahe. Kisi kaam k nahe..
3kw say kam inverter me bot masly aty hn
100 Ampire ke battry chl jay ge is k sath
Assalam u alaikum! Fronus pv5200 k Solar pannel 8pannel 540 k lage hain aur 2 tubular batteries lagi huwi hain, iskay saath 2 1.5ton inverter ac aur 2 pankay aur 1 fridge ek saath lag saktay hain?
No
NO. 10 panel kro to 1 ac chaljaiga. Garmio k liye.
Bhai Jan experiment kr k dekhain is trah ap demote mat Krain
Bhai app demote Mth ho na agar ap me ye lharidna hy tho app mera wala lyly barhi mehrabany. 🙏
میں نے بھی pv2200لگایا ہے اس کے کار کردگی ا چھی نہیں ہے
New tubler battery k sath lagana chahiyeh ?
Ji
@@technicalguidanceload kitna utha sakta hai actual mein 1 ton ac chal jai ga?
mery pas fronus xeon 3200va hai abhi install nahe kia . us main koi fault hai ya theek hai ?? 3000 pv attach karon ga
وو بھی بس گزارا ہی کرتا ھے اتنا کوئی اچھا نہیں ھے ۔
60000 tk 2kva me konsa acha inverte rhai
Pv 2200 vs zeiwnic aim 1.5 which is good
@Technical Guidance bai mainy 2000W wala xeon model lagaya ha without solar pannel with tublar battery tx-1800 lakin iska last cell charge nahi hoo raha display pay charging show krta ha last cell
any solution....?
any solution...?
یہی فالٹ ھے اس ماڈل میں
@@technicalguidance koi hal ha iska...?
Bro Maine suna tubular battery solar ke baghair nakam hai sahih charge Nahi Hoti aap koshish Karo solar lagalo
جنھیں کچھ نہیں پتہ وہ ایسے ہی بولتے ہیں لیکن نو پرابلم ٹیوبلر بیٹری کو سولر کے بغیر بھی چارج کروا سکتے ہیں ہر چیز کا حل موجود ہے ۔
میرے پاس inverex veyron 1.2 kw ہے میں یہ لینے کا سوچ رہا ہوں میں نے 2 پلیٹیں لگانی ہیں 545 کی آپ کیا مشورہ دیتے ہیں
Thek hey le lain agr ap ziada panel lgana chahtay hain to
Na Lena bkws hy
میں نے دو ماہ پہلے فرونس پلاٹینیم سیریز پی وی 3200 لیا ھے لیکن نہ تو روٹر موٹر چلاتا ہے اور نہ ہی ڈیڑھ ٹن اے سی چلاتا ہے ۔ اب میں کیا کروں ؟ پیسے بھی اتنے نھیں کہ چینج کر سکوں ۔
Ap ne with out consultation lia hey isi liay problem aa gai hey
Pv3200 bhe sahe nhe hai
Same problems in 3000 whats
Fronus company 2 no ha in k aksar inverter my masayal he ha banda zaleel ho jaya
Fronus walay tao phone bhi nahi uthatey aor email ka jawab bhi nahi daity.
Homage ias best
Send me the video of inverter
Homage ghttiya ha.
Maine tho nayetubler battery lagaye hy osaka 1800.185ah ke Sara din charge karta rehtha hy full nahy hothy awar back bhi zyada nahi daytha.
کوئی تو فالٹ ھے ضرور اس میں
O bhai pv 2200 upgraded verion hao 2100 ka
please kuch bhi 😁
Thank you bai
Mai nai tho yahi invertor abi lagaya hai. Pannels 415 Watt k 5 pannels hai aik tubler batory hai 180 AH
Abe tho kam sahi kar raha hai baad mai shyd masla karay
Ye 1200watt ka tark load bardasht krta ha kia
Krta hey
@@technicalguidance sir apnay is video me btya k ye purani refrigerator pr trip ho jta ha .jb ky uska tark 1.2kw se 1.3kw hota ha .. plz guide krdein .. mujhy inverter Lena ha jis pr purani refrigerator or red water motor chaly jye.load manage krlo ga .aik time me aik Chez . plz reply
Asalam o alaikum Kysa chl rha ap ka pv2200
@@FarooqAhmadGDL walakum salam
Tek chal raha hai Alhamdulillah
Abe aik pannel increase kar le hai. Total 6 pannels ho gaye hai. 415 watt per pannel
بھائی اس پر لال واٹر پمپ جو 1hp کا ہوتا ہے وہ چلا کر دیکھا ہے؟
وہ بھی چل جاتا ھے لیکن انورٹر اورلوڈ ہو جاتا ھے ۔
@@technicalguidance overload kitni daer bad hota hai? Mtlb pump kitne time chala sakte
بالکل نہ چلائیں
@@technicalguidance بھائی کبھی اگر ایمرجنسی میں ضرورت پڑے تو موٹر چلا سکتے ہیں ؟
No
Fronus totaly wast of money
Sir ma na b ya lagay ha 1.6kw overload hogya ha 09 error ha
Kitne load pr overload error dy raha hai
Battery back up pai 1300 mai
Bhai shayad apne iski setting nhi ki... isliye apk sath ye sab issues hain.... jab k mere pass aisa koi issue nhi ha
Bhai mery sath b yehi same problem a rhi h please ap apni settings bata do
@@amanitali104 g ap manual read karen or setting kar len... agr kuch samjh na aye to mujse poch len
آپ نے شائد ویڈیو پوری نہیں دیکھی ۔سب کچھ کیا تھا
@@technicalguidance apne is video ma jo b problms batai hain wo sirf or sirf setting na hone ki wajha se arhi hain... bcz mere sath b yehi sab tha... usk bad settings ki or sab kuch tjek hogua
@@nadeemshaikh9690 kindly apni settings bta dain
hmare yahan koi imaan nam k chez nhi ha logon k 55 hazar waste kr rhe hn Fronus wale...🙄🙄🙄...Allah hi in se poche ga
Allah frounas walo ka bairha gharak kary
Phir konsa lena chaye 2kva
السلام علیکم
سروس سینٹر سے اس کا سافٹ ویئر اپڈیٹ کروا لیں تمام مسئلے حل ہو جائیں گے
Exactly 👍🏻
Bhai kon sa version karwaoon
Ghut na bolo
Bro ye video purani hey ab software upgraded ho chuka he
Bhai yeh inverter 80×12=960w solar genrat karta hai To ham is ko 1500w solar de kar apni 960w ki makdar hasal kar sakte hain.jab is ne 960w he dene hain to ham is ko 2000w kenw dain compni wale hame bewakoof bante hain
U are great bro,,❤
Solar panels Kabhi bhi complete watts Nahi daite mere pass 8 penals Hain 150 watts ke or mughe 800 watt milte hain
Fronus pv5200 our pv
7200 me koi masla to nai hai agar hai to plzz bta dein mene purchase karna hai
Fronus Pakistan may Banta hy ap koshish karo solar max, ya Tesla, ya phir inverex khareedain
03006715530 whatsapp par Voice message krain & please don't call me 🙏🏻بھائی کال نہ کیجئے گا