@@careervision9762 transformer mein ek dusra winding ke sath koi electrical connection nahi hota hai.. All are electrically isolated, electromagneically connected
@@careervision9762 harmonics produce in high amount in traction winding due to IGBT switching in SR, to reduce those harmonics flux harmonic filter winding is placed near traction winding. For maximum amount of harmonic flux to link with harmonic filter winding... Thats why in 3 phase loco power circuit drawing 4 harmonic filter winding is drawn beside of 4 traction winding..
Line Harmonic Filter is connected with Primary winding of main transformer which consist of resistors and capacitors. The Harmonic Filter reduces the high frequency harmonics to avoid disturbance in signaling. ... The complete Resistor Assembly is mounted on the roof of the Locomotive.
Good explanation thank you
Harmonic filter traction winding ke paas hota hai
Electromagnetically connection Transform ke primery ke across hota hai
@@careervision9762 transformer mein ek dusra winding ke sath koi electrical connection nahi hota hai.. All are electrically isolated, electromagneically connected
Yes they are electromagnetically connect to primery .. there physical location may vary.. I also want to say that only
@@careervision9762 harmonics produce in high amount in traction winding due to IGBT switching in SR, to reduce those harmonics flux harmonic filter winding is placed near traction winding. For maximum amount of harmonic flux to link with harmonic filter winding... Thats why in 3 phase loco power circuit drawing 4 harmonic filter winding is drawn beside of 4 traction winding..
Line Harmonic Filter is connected with Primary winding of main transformer which consist of resistors and capacitors. The Harmonic Filter reduces the high frequency harmonics to avoid disturbance in signaling. ... The complete Resistor Assembly is mounted on the roof of the Locomotive.
Inin question no. 17, speed of wap7 is -130kmph.
Please share the reference
Hotel load output 750 volt
Yes output Voltage is 750 V but question no 19 Is related to KVA rating, not voltage
Sir Plzzz upload more objectives
Ok.
Sir good morning. Please explain in English. We are south Indian
1st-1096
For conventional loco It is 1096 mm but for three phase loco It is 1092 mm. Proposal has been send to RDSO to enhance upto 1096 mm
Sir, WAG9 LOCO ka gear ratio 15:77 , 21:107 both hota hai
6 no. me 21:107 bhi right hai
WAG-9H का gear ratio 21:107 होता है।
More videos sir nice explain with good queation