Oxygen analyser. Why Oxygen analyser installed between economizer and airpreheater ?

Поділитися
Вставка
  • Опубліковано 11 вер 2024
  • For more videos
    For FITTER, TURNER, WELDER THEORY
    • Fitter theory and MCQ ...
    For BOILER OPERATION AND BOE EXAM
    • BOILER Operations And ...
    For DIESEL MECHANIC AND AUTOMOBILE ENGINEERING CLASSES
    • Automobile Engineerin...
    Oxygen Analyzers. ... An oxygen analyzer for stack gas measures the content of oxygen in the exhaust gas after combustion. It provides data to help control the fuel-air ratio in the combustion process. The fuel-air ratio in the combustion process is crucial when optimizing combustion and boiler efficiency.
    How does an oxygen analyzer work?,How does a paramagnetic oxygen analyzer work?How do you calibrate an oxygen analyzer?What is o2 trim?

КОМЕНТАРІ • 63

  • @ashishjaiswal6140
    @ashishjaiswal6140 4 роки тому +3

    This is the most important video for BOE exam tq Sir ji

  • @ashishvitekar3474
    @ashishvitekar3474 3 роки тому +2

    Very very nice explain and informative videos.
    How to monitor and check that furnace conditions are OK with the help of O2 analyser.
    What are the standard Value of O2 to maintain healthy combustion in furnace.
    Thank you

  • @PankajYadav-zg3co
    @PankajYadav-zg3co 11 місяців тому +1

    Tq

  • @sandeshsonawane3868
    @sandeshsonawane3868 3 роки тому +1

    Outstanding explanation 👍

  • @sachinsaraswat1186
    @sachinsaraswat1186 3 роки тому +2

    Everything is good .....thoda sa auto focus ka problem hora h 👍

  • @shashibhatia167
    @shashibhatia167 2 роки тому +1

    I wanna know 1 thing that is at economizer inlet,the temperature of flue gas is 430°C to 450°C.It means that at inlet of economizer,the temperature is higher than the ignition temperature of FC, Hydrozen and sulphur.It means that ki complete combustion to economizer ke inlet pe hi ho jaaega due to more temperature at economizer inlet.So,why we can't install Oxyzen analyzer at economizer inlet?

    • @yjsuccesstrack7275
      @yjsuccesstrack7275  2 роки тому +1

      Completely combustion tem par HI to oxygen check karenge dost...... Complete combustion ke Bad jo air hoga wahi to excess Air hoga ok

  • @parveenkumarswain5070
    @parveenkumarswain5070 11 місяців тому +1

    Why fuel is completely not burnt before inlet of economiser pls explain

  • @ashishvitekar3474
    @ashishvitekar3474 4 роки тому +1

    Very good information, I am got satisfaction

  • @worldinstrumentationengineer
    @worldinstrumentationengineer Рік тому +1

    excellent ji

  • @babloochauhan9949
    @babloochauhan9949 2 роки тому +1

    Once through boiler per video banayia

  • @cgpurshottamm7535
    @cgpurshottamm7535 4 місяці тому +1

    Bhaiya ecses air kaha se dete hai

  • @sujitpadvi
    @sujitpadvi 3 роки тому +1

    Bahut badhiya..laga yj sir..👍

  • @arindamghatak
    @arindamghatak 3 роки тому +1

    How do you get the following conclusion as highlighted at 5:55....10% increase in excess air will cause 3% increase in fuel consumption ?

  • @mahakal5169
    @mahakal5169 4 роки тому +2

    super sir

  • @krunalpuri4707
    @krunalpuri4707 4 роки тому +1

    Wow nice video sir
    Ke video MDC Ka baneya

  • @rakeshchawhan5277
    @rakeshchawhan5277 3 роки тому +1

    Super

  • @ashishjaiswal6140
    @ashishjaiswal6140 4 роки тому +1

    Superb video sir

  • @pradipjain4670
    @pradipjain4670 4 роки тому +1

    Thankyou

  • @vinaybastawade7068
    @vinaybastawade7068 3 роки тому +1

    Supb sir

  • @nirajsinhmakwana3359
    @nirajsinhmakwana3359 3 роки тому +1

    Nice video sir

  • @arindamghatak
    @arindamghatak Рік тому +1

    You have written Flue gas as Fuel Gas. Kindly correct this.

  • @ompalyadav824
    @ompalyadav824 2 роки тому +1

    Thank you very much sir 🙏
    Sir mujhe online coaching krna h

  • @kesarinandan8181
    @kesarinandan8181 4 роки тому +1

    Kitne tph k boiler me kitne inches ka IBD ya CBD valve lagayA jata hai.

    • @yjsuccesstrack7275
      @yjsuccesstrack7275  4 роки тому +1

      CBD ka pipe boiler capacity se sirf 5% blow down kar sake ayese designed kiya jata hai....
      And IBD jo hai TDS and BMCR par designed kiya jata hai eske liye.. Jaise aapka boiler 10 kg/cm² par steam generate krta hai to 1" ke pipe se 480 kg water relig krta hai... Esliye pahale aapko blow down percentage nikalna pdega fir pipe diameter and blow down time kitna hona chahiye o nikal skte hai

  • @Sandeepyadav-wu2un
    @Sandeepyadav-wu2un 4 роки тому

    Ok sir ji

  • @ivanfadillah1936
    @ivanfadillah1936 2 роки тому +1

    hi sir, could you provide the information in English? I need to understand that. Thanks

  • @subashpal9403
    @subashpal9403 4 роки тому +1

    Nice video

  • @sujitroy3860
    @sujitroy3860 2 роки тому +1

    What is full form of nm3 ?

  • @ompalyadav824
    @ompalyadav824 2 роки тому +1

    Sir total kitna o2rkhe

  • @er.shambhu4520
    @er.shambhu4520 3 роки тому +1

    Sir is pr numerical video plzz

  • @ashishjaiswal6140
    @ashishjaiswal6140 4 роки тому +1

    Sir please water circulations and steam circulations ka video Nanaiye

  • @krunalpuri4707
    @krunalpuri4707 4 роки тому +1

    Sir o2 ziyda or o2 kaamho Jai to kaykari ge

  • @pareshpande7111
    @pareshpande7111 3 роки тому +1

    Oxygen percentage ketna hona chahiye

    • @yjsuccesstrack7275
      @yjsuccesstrack7275  3 роки тому

      Sab fuel ke liye alag alag hota hai dost,,, ldo ke liye 4-5%
      Cog + BFG ke liye 3%
      Pcm ke liye 5%
      Coal ke liye 5-6%

  • @vishalsarang2999
    @vishalsarang2999 4 роки тому +1

    DCS मै कसें करे करे drum leval control plz shear this video

  • @pradipjain4670
    @pradipjain4670 4 роки тому +1

    Ok

  • @ompalyadav824
    @ompalyadav824 2 роки тому +1

    Sir good morning please sir mo nambar

  • @nareshswami5562
    @nareshswami5562 4 роки тому +1

    Nice video sir