How To Use & Install a Floor Probe

Поділитися
Вставка
  • Опубліковано 22 січ 2025

КОМЕНТАРІ • 10

  • @shughy1
    @shughy1 2 роки тому +1

    I'm replacing my existing thermostat and got a new probe included, do they all work the same, like can I just wire in the old temp floor sensor into the new thermostat? 🤔 As I don't really want to lift floor just to add a probe I might not even need

    • @WundaGroupPlc
      @WundaGroupPlc  2 роки тому +1

      The standard probe that is already installed will be fine to work with the Smart Square stat, it would be wired into terminals 1+3. The polarity for the cables does not matter. Hope this helps - Wunda

    • @shughy1
      @shughy1 2 роки тому

      @@WundaGroupPlc thanks so much, I just wasn't sure since the old thermostat was a different brand etc. Maybe the floor sensor tech is fairly universal though

    • @WundaGroupPlc
      @WundaGroupPlc  2 роки тому +1

      @@shughy1 No problem at all. Should you have any other questions our technical support team (based in South Wales) are available Monday - Friday: 8am - 6pm
      Saturday: 9am - 4pm via email techsupport@wundagroup.com or Tel: 01291 634140

  • @mak.ak.uk.
    @mak.ak.uk. 2 роки тому

    I have screed laid over the underfloor heating pipes (Wunda / wet system).
    At what level should the probe be installed?
    A) At the same level of the pipes,
    B) towards the top of the screed, or
    C) on top of the screed and just under the floor (amtico)?

    • @WundaGroupPlc
      @WundaGroupPlc  2 роки тому

      The probe should always be installed directly below the floor finish with the tip of the probe in contact with the floor finish. For Amtico, this would mean channelling out a small amount of the screed to accommodate the cable and the probe head should sit slightly proud of the screed in order to be in contact with the floor finish. - Wunda

  • @CYanideUK1
    @CYanideUK1 6 років тому +7

    You need to run the probe through conduit under the floor so it can be replaced if it fails

    • @handle1196
      @handle1196 2 роки тому

      Any idea what size the probe is? Would the conduit required be larger than 16mm pipe?

  • @brendon72
    @brendon72 7 років тому

    Does the probe wire travel under or over the pipes in the overfloor panel?

    • @DavePawson
      @DavePawson 6 років тому

      Reading suggest neither, as per video, i.e. parallel with pipes.