  • Reviewing of 0-320V Output LED TV Backlight Tester LED Strips Test Tool with Current and Voltage Display for All LED Application جهاز اختبار الليد_UPDATED 2022
    0-320V Output LED TV Backlight Tester LED Strips Test Tool with Current and Voltage Display for All LED Application
    XIAOYUN
    LED (TV Backlight) Tester
    Model: XY284-GHB
    Service Voltage : AC85 ~ 265V
    Output Voltage : 0 ~ 320V (DC)
    Output Current : 0 ~ 40 mA
    01:50 Features
    01:58 Instruction
    02:01 Test skills
    02:39 Dimensions
    04:25 Measuring the tester output DC voltage with a multimeter
    05:00 Check LEDs bar
    11:43 Check LED beads
    14:52 Check LED bulb
    15:38 Check LED strip lights
    15:47 Check different types of LEDs
    18:06 Check zener diode voltage
    19:11 Check capacitor charging
    19:33 Check diode
    20:13 What appears on the display in case of short circuit
    Features
    1. Test TV backlight without opening the screen
    2. LED reverse fault, not burning lamp
    3. Display output voltage, output current
    4. High brightness, high voltage output, compatible with lighting all models
    5. The transformer is insulated from heat and heat
    6. The lights are lighting up to protect the eyes
    7. The voltage current is adjusted automatically according to the number of LED lights
    8. Two current switching
    Instruction
    1- Plug in the power (AC85 ~ 265V), wait a moment: after the instrument voltage shows the highest voltage of 320V (DC), insert corresponding red black marker, you can start the test.
    2- In the test, the red and black pen will be exposed to the positive negative electrode of the LED, and the light source will automatically be slowly (3 ~ 5s). Rise to highlight and stabilize. If you don’t want to be too bright, you can pick up a pen when you feel the right brightness. The process can be repeated during the next test.
    3- The instrument adopts the output voltage to adapt automatically, the current can be automatically raised by the small to large, and the light can not be burned without electric shock. It is not easy to use the indirect and indirect lamp beads to avoid burning, but it is possible for the low-quality single bulb in the reverse breakdown, the single lamp bead does not recommend trying to reverse.
    4- LCD screen backlight test method :
    1- Remove the interface socket of the constant current plate and the lamp bar.
    2- The red and black stylus of the instrument correspond to the positive and negative electrode inserted into the LED lamp bar.
    3- Turn on the power of the TV and make the TV (except the constant flow plate) normal. At this point , if the lamp is normal, the LCD screen, main board and logic board are normal, you can see the positive on the screen The usual picture is that the brightness
    4- Digital display real-time voltage: the voltage shall be the same for each set of lights in the same TV, and if the voltage error exceeds when the test is tested Over 3V, the voltage of the lamp bar may be problematic. Also can compare with the good light bar of the same model, by contrast voltage judge the good and bad of the backlight.
    5- Test skills :
    1- When the test is tested, show voltage = open circuit voltage, indicating that the lamp bar may be connected to reverse or open circuit failure.
    2- When the test is tested, the display circuit = 000V, indicating that the lamp bar or bead is short-circuited.
    3- When testing two objects without electrical connection, if the display voltage is significantly lower than the open-circuit voltage, this is indicated. There was a leak between the two subjects.
    Do not touch both end of the probes at the same time.
    Please disconnect the power, when not in use.
    www.aliexpress...
    WARNING:
    This video is for demonstration and educational purposes only. Each demonstration presents risks and hazards that must be fully understood before attempting.
    And should be performed only by professionals
    Disclaimer:
    The information, demonstration, and any content contained in this video are for informational purposes only. PLEASE READ Warning… do this at your own risk. I am not responsible for what you do to your device.
    MUSIC:
    Track title: Drop - Anno Domini Beats
    From: UA-cam Audio library
    IMAGE:
    Quranic Dua #35 (Surah al-Ahqaf)
    From: quranicquotes....
    I have approval from the site quranicquotes.com to use the images

КОМЕНТАРІ • 14

  • @waelsalem9955
    @waelsalem9955 Рік тому +1

    جزاك الله كل خير
    وشكرًا جزيلا لك
    وأتشرف بمتابعة قناتك

  • @halanoure6407
    @halanoure6407 2 роки тому +1

    اللهم صلى على محمد وال محمد الائمة والمهديين من ولده وسلم تسليما🏴❤🕊

  • @LeDocteurPC
    @LeDocteurPC Рік тому +1

    thank you

  • @jojosweet6263
    @jojosweet6263 2 роки тому +1

    بالتوفيق ان شاء الله

  • @sncat
    @sncat Рік тому +1

    Для безопасности проверки одного, установи переключатель, замыкание выхода через сопротивление 1 К 2 Вт, включается ограничение выхода 30 вольт. Позволяет не повредить изменение одного свето-диода при обратной полярности. protected one led, reverse polar, output red and black 1 K 2W (switch). 30V max.

  • @hugowalterespinozaventuro8452
    @hugowalterespinozaventuro8452 Рік тому +1

    Lastima q no trae más de 50 m.a hay otros modelos q traen hasta 300 m.a

  • @panagiotiskiriakos365
    @panagiotiskiriakos365 Рік тому +1

    if you touch both probes .. is it dangerous ?

    • @LEQSBeaprofessional
      @LEQSBeaprofessional  Рік тому

      It is written in the specifications of this device that not touch both ends of the probes at the same time, So it will definitely be dangerous.