Size of Beam and Steel Rod Diameter for 20ft Span | Civil Engineering Basic video |

Поділитися
Вставка
  • Опубліковано 4 сер 2021
  • 1) Construction cost of 1000 square feet House 2019? Cost of House Construction per square foot 2019
    • Construction cost of 1...
    2) Grade Of Concrete and water Cement Ratio
    • Grade Of Concrete and ...
    3) How to calculate Cement, Sand, and Aggregate for M20 concrete
    • How to calculate Cemen...
    4) Depth of Footing/Foundation and Reinforcement details in Foundation
    • Depth of Footing/Found...
    5) Maximum distance between two RCC columns?
    • Maximum distance betwe...
    6) Big Mistakes in RCC Slab - Lapping Mistakes
    • Big Mistakes in RCC Sl...
    play Lists :
    Construction Videos :
    • How to Chose Good Qual...
    Construction Site Visit :
    • New Exterior Design fo...
    House Planning Play List :
    • How to Study Column wi...
    #CivilEngineers #CivilEngineering

КОМЕНТАРІ • 61

  • @ArunSingh-wh2eh
    @ArunSingh-wh2eh 7 місяців тому

    Even for a layman with no background in civil construction the explanation is very nice 👍

  • @edwinmoree833
    @edwinmoree833 2 роки тому +4

    We love your video.
    The love and care you show your fellow man is amazing.
    To pay for an education and yet share your knowledge freely to help others is what education started as.
    Here in USA engineers would never do that.
    THANK YOU SO VERY MUCH,
    Edmoree

  • @red-hat-mike
    @red-hat-mike 2 роки тому +8

    In USA ... residential wall thickness is 8" concrete brick ... so for a 20 ft span ... the depth of the BEAM is 20" ( 1" for every 1 ft of span ); 2 x #5 crank bars should be installed at L1 and L3 with 1 ft 90 deg corners with stirrups 4" (8mm, 135 deg 3") The support COLUMN will be 8" x 20" ( 8 #5 rebars; 8mm steel hoops L/3 .... L1= 4" spacing; L2 = 6" spacing; L3 = 4" spacing) etc etc

  • @sarathmeegodawithana6552
    @sarathmeegodawithana6552 Місяць тому

    Thanks lot its real explanations.

  • @user-dp9vu9zf6n
    @user-dp9vu9zf6n Рік тому

    Bahut behtar bayan karte h aap

  • @kannansenthilkumar5229
    @kannansenthilkumar5229 2 роки тому +6

    Sir! That beam size 12"/14" including slab thickness or without slab thickness.tq

    • @kzyinfo
      @kzyinfo Рік тому

      the beam size 12 inches x 14 inches is including concrete cover or not?
      is it total beam size or stirups size?

  • @akojuravisankar3492
    @akojuravisankar3492 2 роки тому +1

    God bless you. You need make more and more videos

  • @red-hat-mike
    @red-hat-mike 2 роки тому

    Excellent video.. thanks

  • @tsewaviah
    @tsewaviah 2 роки тому

    Great job brother

  • @skpkd9786
    @skpkd9786 2 роки тому

    👌👌👌 most awaiting video

  • @salimmahmud1614
    @salimmahmud1614 2 роки тому +3

    Hello there
    One of my friends added 3 (16 mm) bottom ) and 3 (16mm) rods on the top moreover, he put two extra support as you mentioned. The length of the span is 14’ and the beam size is 12” by 12” and the column size is also 12 by 12” and he added 8 rods of 16mm.
    My question is, how many story he might build up in that case. Please explain

  • @himanshusing21
    @himanshusing21 2 роки тому

    Great help with this video

  • @aaliyahkhan8565
    @aaliyahkhan8565 3 місяці тому

    How should u calculate the depth and width of beam?

  • @adsamgideon9465
    @adsamgideon9465 2 роки тому

    Hi, thanks for the video. I wonder if the beam size would satisfy deflection criteria. 20" deep is a safe suggestion

  • @Sarojkumar-xe2qi
    @Sarojkumar-xe2qi 10 місяців тому

    Great video sir

  • @krishnakondapalli6015
    @krishnakondapalli6015 2 роки тому +1

    At what basis you decide the size of beam and can you explain this model for plinth beam

  • @hemantasingh8606
    @hemantasingh8606 2 роки тому

    Thank you so much

  • @mshafiq809
    @mshafiq809 Рік тому

    I want to this info for commercial buildings

  • @talithaiitalithaii7261
    @talithaiitalithaii7261 2 роки тому

    👍👍👍
    From Mizoram
    😘😘😘

  • @simlowsb
    @simlowsb 2 роки тому

    Why if 3 storey we need to add additions rebars in the mid section of the beam? Wouldn't the beam be only calculated based on the carry load of the slab or what ever is on top of the beam that is transferring the loan. I can understand if it was a column for 3 stories we add additional rebars at the ground floor due to total transfer load from 1st + 2nd floor. Looking forward to your reply. Many thanks.

  • @satheeshkumarthirunamalai9215
    @satheeshkumarthirunamalai9215 2 роки тому +1

    What is the size of column and rebars used for column?

  • @sajalrahaman4719
    @sajalrahaman4719 Рік тому

    For 25 feet distance can I prefer this 12" * 14" ?

  • @saarthakkumarlal6371
    @saarthakkumarlal6371 2 роки тому

    Sir beam size is including slab thickness or without slab thickness...??

  • @jaroslavbroulik5529
    @jaroslavbroulik5529 2 роки тому

    Hello, I would like to ask you for recommendation. Beam above the garage door (the garage has only the ground floor)....span = 17ft. Stirrup 6mm every 250mm. Beam size will be 12"x 20" ... Rod diameter = 2x 12mm above, 2x 18mm below. Is is enough? There are no crank bars. Should I add some? For example 2x 12mm...? Best regards

  • @shankars3744
    @shankars3744 2 роки тому

    Including slab the beam size need to be 12x14 inch??

  • @shenoyglobal
    @shenoyglobal Рік тому

    can the top steel rod dia also be 16 mm for added strength

  • @Aviator0215
    @Aviator0215 4 місяці тому

    Sir, can we provide two hidden beams in a lobby of 20 by 21 feet with 16mm and 20mm rods?

  • @vincentpereira8416
    @vincentpereira8416 2 роки тому

    How about building a 3 story house with 14ft rcc beam what size the beam should be

  • @dreamer69223
    @dreamer69223 Рік тому

    Is 12mm 5 bars, 16 mm 1 bar enough For 14 feet beam ( top 3 - 12mm, bottom 2 - 12mm and 1- 16 mm)??

  • @piotrbrzdek1106
    @piotrbrzdek1106 2 роки тому +2

    as I understand it, the beam is counted together with the thickness of the floor slab. In Poland, the beams are rather tall than wide, high / wide approx. H / B = 2

  • @emaneman2856
    @emaneman2856 2 роки тому

    Hey brother, I want to know why did you use 4 steels at the bottom of the Beam which is the width?

  • @hariprasad3256
    @hariprasad3256 Рік тому

    Can we keep 11ft distance between two columns
    If colum size are 18 by 9 inches

  • @abdulcaderrawuther1014
    @abdulcaderrawuther1014 2 роки тому

    Need to know how that differ commercial & domestic design.

  • @bijumohan687
    @bijumohan687 2 роки тому

    Sir can I make 16*15feet rcc flat roof on load bearing wall with out a beam

  • @tamuzhs3095
    @tamuzhs3095 2 роки тому

    More than 30ft of length beam to join columns are possible sir

  • @nirmalbopearachchi9862
    @nirmalbopearachchi9862 2 роки тому

    Thank sir good vedio

  • @joshuablaze6536
    @joshuablaze6536 2 роки тому

    After watching yr 25ft beam width video I was sceptical about what could be the size of my 18x17ft beam . Now I'm clear. Fortunately I used 14x14 for the beam size. I hope that will hold it eternally.

  • @AA-pf6ed
    @AA-pf6ed 2 роки тому

    If span was 6.8m, will be same design?
    I want design mosque span 14mx18m

  • @balrajkotakari8041
    @balrajkotakari8041 2 роки тому

    Hai sami... Today's domestic House construction "9" ench wedth... Pillars and beams... This size topic vedios iwant.....

  • @BehatAcademy
    @BehatAcademy Рік тому

    If there is 9 imch wall in between then?

  • @AA-pf6ed
    @AA-pf6ed 2 роки тому

    What size of columns in meter, and size of beam section n meter

  • @Abir.babu07
    @Abir.babu07 2 роки тому +2

    For single room ground floor and first floor.. Room size 12 feet by 10 feet..
    Then what should be the size of beam

  • @faridquaye4766
    @faridquaye4766 Рік тому

    Thank u sir, please if u have an industrial steel shed of 36m x 100m. Using steel columns of 250 x 250 x 72kg/m. What would be the beam or rafters size to use. Please and estimated value if possible. Thank you

  • @mangjca3009
    @mangjca3009 2 роки тому

    Sir what does it mean center to center?

  • @karannikam7076
    @karannikam7076 2 роки тому

    Sir Colmuns ki size kya hai and steel bar kinte mm ke hai or kitne hai

  • @simplified121
    @simplified121 Рік тому

    For commercial building

  • @themimic-chetanubale1603
    @themimic-chetanubale1603 Рік тому

    For 15 fit column column distance, beam steel reinforcement details

  • @RMKserve
    @RMKserve 9 місяців тому

    بھائی جان آپ نے یہ نہی بتایا کہ پاکستان کے اندر کون سے اسٹینڈرڈ استعمال ہوتے ہیں. IS یا کوئ اور. اس بیم کے سائز میں آپ نے Tension zome اور کمپریشن زون کون سے ہیں
    4 سریے نیچے کیوں اوپر کیوں نہی؟

  • @curiosityu9359
    @curiosityu9359 2 роки тому +1

    Sir the beam depth should be calculated by L/10 or L/12 . Where L is distance between two columns. So as per that the beam depth should be 22 inches or 2 feet depth for 20 feet span RCC slab. But here u said the depth should be 14 inch.
    I think u R misleading us. 😨😨😨

  • @nirmalbopearachchi9862
    @nirmalbopearachchi9862 2 роки тому

    🙏

  • @subasvaralakshmi2716
    @subasvaralakshmi2716 2 роки тому +1

    Mostley 9 inch wall howe to provide 12 inch beam

    • @raushansingh3883
      @raushansingh3883 2 роки тому

      Mostly 10inches columns and wall ..use in domestic building how can I use width of beam 12 inch...
      Can I use 10 inch or other..

    • @edwinmoree833
      @edwinmoree833 2 роки тому

      Make columns 9x12

  • @nageshyadav4414
    @nageshyadav4414 Рік тому

    सर अगर आप हिंदी में बताते तो सबको समझ में आते

  • @muralidharankamreddi5932
    @muralidharankamreddi5932 Рік тому

    If beam size 9"x14'

  • @adiralasudararao2680
    @adiralasudararao2680 Рік тому

    31.6" span beam

  • @nawalshrivastav6032
    @nawalshrivastav6032 Рік тому

    Please hindi language use

  • @yaswanthkumar8161
    @yaswanthkumar8161 Рік тому

    Orey pichi ga yendhu wrongs chestavvu?

  • @rizwananjum9726
    @rizwananjum9726 2 роки тому +1

    What is this non sense.designe of beam(depth and steel) depend on the load,size of Penel, etc.this all is Jogard method

  • @mshadaabakhtar557
    @mshadaabakhtar557 2 роки тому

    May i give this beam size in three story building ...??