Piperack Loading | Different pipe Loads on Piperack | Piping Mantra |

Поділитися
Вставка
  • Опубліковано 6 січ 2025

КОМЕНТАРІ • 24

  • @pratikgulve6150
    @pratikgulve6150 Рік тому

    Good work

  • @subhajitmukhopadhyay4780
    @subhajitmukhopadhyay4780 8 місяців тому

    Great one! Please make a video on WIND LOAD on this structure (only pipe wind load is considered here).

  • @siranjgv7312
    @siranjgv7312 Місяць тому

    mam 12" pipe has udl of 15kn/m is how did you calculate?

  • @cck0728
    @cck0728 3 роки тому +1

    Excellent video. At 3:40, why 40 KN load is being considered for anchoring load?
    Thanks.

  • @pratikgulve6150
    @pratikgulve6150 Рік тому

    Add more videos on Piping & equipment,project management

  • @keyursbhatt1989
    @keyursbhatt1989 3 місяці тому

    Please mam make vedio of dyake wall height calculations

  • @sathyadev4898
    @sathyadev4898 2 роки тому

    Thankyou, you are helping us a lot madam!!! how to apply 'thermal/friction/guied loads' in staad pro

  • @pratikgulve6150
    @pratikgulve6150 Рік тому

    Wonderful world

  • @surinderghurdora8537
    @surinderghurdora8537 Рік тому

    Do u provide course for pipe rack as per IS code

  • @rahul4ubeind
    @rahul4ubeind Рік тому +1

    can we do same way for column and other structural platforms?

  • @pavantekale5510
    @pavantekale5510 2 роки тому

    Nice video really helpful. What is criteria to be followed for fixing anchor bay location in plant .

    • @PipingMantra
      @PipingMantra  2 роки тому

      Probably at the center or pipe rack and all equipment connection

  • @kunaldeshinge2865
    @kunaldeshinge2865 2 роки тому

    mam please make video on how these loads are applied in staad

  • @PANKAJYADAV-1991
    @PANKAJYADAV-1991 Рік тому

    mam from where have you consider 7.5% of total operating weight?

  • @ganeshsangam9484
    @ganeshsangam9484 2 роки тому

    What is anchor bay support

  • @krj7735
    @krj7735 2 роки тому

    Mam how to apply these loads in stadd pro

  • @aslsay
    @aslsay 11 місяців тому

    How load 10.2 kn per Mt without selecting steel members size. Just video

  • @bhuwanesh9.81
    @bhuwanesh9.81 Рік тому

    Please give the reference of standard/code of your calculations and assumptions.

  • @rohitnikam3647
    @rohitnikam3647 Рік тому

    What is mean off plot and on plot pipe rack

  • @sandeeppathak2194
    @sandeeppathak2194 3 роки тому +1

    👍

  • @sarwarbilgrami8213
    @sarwarbilgrami8213 3 роки тому

    Noice

  • @jeysretherthamaraiselvi5126
    @jeysretherthamaraiselvi5126 3 роки тому

    i need staad model & design document share your mail id