RV Meter Base Install Ep 78

Поділитися
Вставка
  • Опубліковано 18 гру 2024

КОМЕНТАРІ • 106

  • @itsMe-lx9fw
    @itsMe-lx9fw 2 місяці тому +1

    How much does something like this cost???

  • @bhaley51
    @bhaley51 19 днів тому +1

    How deep did you have to run your electrical wiring?

  • @comingtofull-ageinchrist6736
    @comingtofull-ageinchrist6736 2 місяці тому +1

    I had the new owner of the mobile home park I live in offer me work to install a few RV outlets for a few of the lots where I live but not sure what to charge for labor to install an outlet on an existing service so they can rent the lot to an RV owner.
    I’m a licensed unlimited Journeyman but haven’t a clue what to charge above the cost of materials.
    I figure I would dig a hole for a 4x4 post to mount an RV 50 amp box and run a short piece of Carflex to the panel and install a 50 amp breaker for it. Just not sure if 300 would be too much for labor or not enough?
    Any feedback or suggestions?

    • @NoneyaTexasontheback20
      @NoneyaTexasontheback20  2 місяці тому +1

      Electrician here gets $1000

    • @comingtofull-ageinchrist6736
      @comingtofull-ageinchrist6736 2 місяці тому +1

      @@NoneyaTexasontheback20 is that for adding new service or adding a RV hook up to an existing service?
      Thanks for the information

    • @NoneyaTexasontheback20
      @NoneyaTexasontheback20  2 місяці тому +1

      @@comingtofull-ageinchrist6736 adding to existing

    • @comingtofull-ageinchrist6736
      @comingtofull-ageinchrist6736 2 місяці тому

      @@NoneyaTexasontheback20 The meter pedestals we have here have an opening for two double throw 240 volt breakers and a single throw 120 volt.
      All I’m looking at on labor is digging a hole for a 4x4 post to mount the box on next to the disconnect so I can install a 50 amp and a 30 amp and a 20 amp for a GFCI receptacle. I plan to use a two foot or shorter piece of 1” flex to run my wires to supply power to it.
      I don’t plan to install a RV meter pedestal, just a box for the receptacles

    • @comingtofull-ageinchrist6736
      @comingtofull-ageinchrist6736 2 місяці тому

      @@NoneyaTexasontheback20 thanks man! Appreciate the info!

  • @MaryDawson-gt6cr
    @MaryDawson-gt6cr 6 місяців тому +2

    Did you have to pull a permit to install?

    • @NoneyaTexasontheback20
      @NoneyaTexasontheback20  6 місяців тому +1

      No permits required… outside of city limits. Thanks for stopping by

    • @MaryDawson-gt6cr
      @MaryDawson-gt6cr 6 місяців тому +1

      @@NoneyaTexasontheback20 I reside in Texas as well Katy to be exact.Im thinking on purchasing some land and trying to figure out the best route to go to aquire electricity.This seems the way to go.Thanks for the response.

    • @NoneyaTexasontheback20
      @NoneyaTexasontheback20  6 місяців тому +1

      @@MaryDawson-gt6cr no problem we have a house in Katy too…. Are you building an rv park or just power for a house…. Process is same you will need a meter pole and base to run power from. Electric company may require something specific depends on what your doing..

    • @MaryDawson-gt6cr
      @MaryDawson-gt6cr 6 місяців тому +2

      @@NoneyaTexasontheback20 No rv park just power for a tiny home or double wide maybe.Trying to figure out the least expensive route to take.

    • @NoneyaTexasontheback20
      @NoneyaTexasontheback20  6 місяців тому +1

      @@MaryDawson-gt6cr ahhh ok. Yes you will need meter pole for either…then from that you can go to house

  • @WanderlustWonderscape
    @WanderlustWonderscape 10 місяців тому +2

    How do you feel about EVs plugging into the 50-amp receptacle? Do you feel that there is any problem with an EV pulling 220V 32 Amps continuously overnight?

    • @NoneyaTexasontheback20
      @NoneyaTexasontheback20  10 місяців тому +2

      Nope. As long as it don’t pull more than 50 amps…. Each tenant pays there own electric bill, they can charge if they want. But the meter will only allow 50 amps

  • @maureenchavis733
    @maureenchavis733 4 роки тому +2

    Good evening. I love watching your channel

  • @my3sonsnh
    @my3sonsnh 2 роки тому +2

    Thanks for the video and link to supplier! About to do the same here in VT...

  • @729Farms
    @729Farms Рік тому +2

    What if you have a metered rv service socket? Do you do a neutral ground bond if it is also the main meter socket? Do you also ground with rod if rv socket is the main power service?

    • @NoneyaTexasontheback20
      @NoneyaTexasontheback20  Рік тому +1

      1st yes you can 2nd yes I would

    • @729Farms
      @729Farms Рік тому +1

      @@NoneyaTexasontheback20 there isn’t a single main breaker, it has 5 slots. 2 pole/50, 1/30, 1/20, and single empty. My thoughts are to run a solid ground from ground bus to neutral bus, and then do 2 ground rods with #6 solid to meet NEC. Thoughts?

    • @NoneyaTexasontheback20
      @NoneyaTexasontheback20  Рік тому

      @@729Farms 50 will require neutral. I don’t have NEC but should be fine

    • @NoneyaTexasontheback20
      @NoneyaTexasontheback20  Рік тому

      @@729Farms I would install main 50 amp breaker. Otherwise you could get full 150-200 amp surge

    • @729Farms
      @729Farms Рік тому

      @@NoneyaTexasontheback20

  • @AyattLLC
    @AyattLLC 2 роки тому +1

    where do you get the meter from?

    • @NoneyaTexasontheback20
      @NoneyaTexasontheback20  2 роки тому

      Jonestown electrical supply!

    • @AyattLLC
      @AyattLLC 2 роки тому

      @@NoneyaTexasontheback20 Do you have a website for them? I can't find them. I am based off Houston.

    • @NoneyaTexasontheback20
      @NoneyaTexasontheback20  2 роки тому

      @@AyattLLC sorry stupid spellcheck Look up JamesTown advanced Products

    • @AyattLLC
      @AyattLLC 2 роки тому +1

      @@NoneyaTexasontheback20 Thanks! I found the RV pedestal. Do they sell the meter that attach to them or does the electric company provide those.

    • @NoneyaTexasontheback20
      @NoneyaTexasontheback20  2 роки тому

      @@AyattLLCthey have meters as well

  • @xinli8046
    @xinli8046 Рік тому +2

    hi Jake, how deep you need to bury the pedestal?

  • @bobbymitchell6916
    @bobbymitchell6916 2 роки тому +2

    can the 50 and 30 amp plugs be used at the same time?

    • @NoneyaTexasontheback20
      @NoneyaTexasontheback20  2 роки тому +1

      no each pedestal is only rated to 50 amp.. its one or the other...

    • @Randomvids1981
      @Randomvids1981 2 роки тому +1

      @@NoneyaTexasontheback20 How much does it cost for the electric company to come out and hook electric up to it

    • @NoneyaTexasontheback20
      @NoneyaTexasontheback20  2 роки тому +2

      @@Randomvids1981 I hooked it all up myself from main pole…the initial cost from electric company was $300 meter service…. I run 5 rv’s off 1 pole

  • @arbitrary4850
    @arbitrary4850 6 місяців тому +1

    The box opening sequence was particularly helpful. Then he sped up the actual install including the wiring.
    Absolutely useless!!!

    • @NoneyaTexasontheback20
      @NoneyaTexasontheback20  6 місяців тому

      The video wasn’t about the wiring. It says pedestal install…. There are other videos on wiring….thanks for stopping by

    • @arbitrary4850
      @arbitrary4850 6 місяців тому

      @@NoneyaTexasontheback20 im not here to beat ya up. you can make your vids however you want. but literally the only step you didnt fast forward through was opening the box. Everything else was fast forward. That part....the opening the box part....i pretty much have that mastered.

  • @christopherray282
    @christopherray282 2 роки тому +2

    Why did you install a meter base and not have the electric company pull a wire and install a meter?

    • @NoneyaTexasontheback20
      @NoneyaTexasontheback20  2 роки тому +1

      I have 14 individual metered spots. Each pay own electric.

    • @bhaley51
      @bhaley51 19 днів тому

      How do you calculate that do you just check the meter usage and then fill them or do they get billed by the electric company?

  • @truesurf
    @truesurf 2 роки тому +2

    You loop the pedestals or run dedicated circuits to each?

  • @anonnymous1427
    @anonnymous1427 4 роки тому +1

    Mb Heritage Farms sent us over, we're already addicted to your channel, New sub! Congrats on the 1000

  • @antoniocisneros2895
    @antoniocisneros2895 2 роки тому +2

    Where did you buy your eclectically box at?

  • @Mr.wilson949
    @Mr.wilson949 2 роки тому +2

    Do you have a rv park? Im new here on your channel. wanting to find a home for my rv.

    • @NoneyaTexasontheback20
      @NoneyaTexasontheback20  2 роки тому +2

      Yes James we own an RV park, my email is on my about page

    • @Mr.wilson949
      @Mr.wilson949 2 роки тому +1

      @@NoneyaTexasontheback20 Ok,thanks. I'll check it out.

    • @NoneyaTexasontheback20
      @NoneyaTexasontheback20  2 роки тому +1

      @@Mr.wilson949 permafr1ed@aol.com

    • @oa6671
      @oa6671 Рік тому

      Would 400 amps supply power for about 14 rvs without any problems or need more amps?

  • @deano5265
    @deano5265 3 роки тому +1

    None Ya Texas on the back 20. What is the 2nd black wire that you attached to the terminal mounted in the middle of the pedestal? Did you install a grounding rod? I am installing the same unit using 4/0,4/0,2/0 wire. I was wondering where to hook the grounding rod wire too as well.
    Dean

    • @NoneyaTexasontheback20
      @NoneyaTexasontheback20  3 роки тому +1

      Dean, there are 2 hots, a ground and a common. The ground rod goes at your panel distribution box. Its extra cost to run it that way, but it is the correct way

    • @deano37
      @deano37 3 роки тому +1

      @@NoneyaTexasontheback20 My installation is calling just 3 wire as noted and a grounding rod. I am running from a transformer installed by my power company to my RV pedestal. So you are going straight from a distribution box and requires a second hot wire? I emailed jamestown and they said I can use that lug for my grounding rod ground.

    • @NoneyaTexasontheback20
      @NoneyaTexasontheback20  3 роки тому +2

      @@deano37 yes you can. I have a distribution panel for several spots and that is where my ground rod is. If you only have one you can put your rod there..that is correct.

    • @deano37
      @deano37 3 роки тому +1

      @@NoneyaTexasontheback20 Excellent. Thank you for clearing that up for me. Would you happen to know if I need to install 2 grounding rods 6ft a part for 100 amp service to RV pedestal? I am running 200 amp wire, but only in case I ever decide to build I will be covered.

    • @NoneyaTexasontheback20
      @NoneyaTexasontheback20  3 роки тому +1

      @@deano37 you should not need to in my opinion

  • @HeritageFarmsTexas
    @HeritageFarmsTexas 3 роки тому +2

    Nice video. I can almost see the money about to roll in.

  • @steveputman468
    @steveputman468 3 роки тому +1

    what amp service is that pedestal ? and do you have link to buying that pedestal ?

    • @NoneyaTexasontheback20
      @NoneyaTexasontheback20  3 роки тому +2

      50 amps.
      www.jamestownadvanced.com/t/category/rv-power-outlets/direct-burial?gclid=CjwKCAjwhaaKBhBcEiwA8acsHPnPXSyhXhaoyfK33ORQrCn-JLJ2okVqvGLPLnG2ATJC8thYJFK1DxoC4L8QAvD_BwE

  • @jessemartinez7241
    @jessemartinez7241 2 роки тому +1

    ? your commen wire (white), should it of been in your middle post.

    • @NoneyaTexasontheback20
      @NoneyaTexasontheback20  2 роки тому +1

      Well not sure I would have to go back and look. Not sure what color my common was…. It works😂. Thanks for stopping by!

  • @doublew030
    @doublew030 2 роки тому +2

    Sir, what wires did you use? I’m going 125 ft and 75 ft. By the way, that video helped so many people. You are a godsend. Got a new subscriber.👍

    • @NoneyaTexasontheback20
      @NoneyaTexasontheback20  2 роки тому +2

      Thanks Double W, #4 will take 50 amps about 200 ft. If shorter can do #6. Depends on if a 30 amp or 50 amp
      #4 for a few bucks is best! Thanks for watching

    • @doublew030
      @doublew030 2 роки тому

      @@NoneyaTexasontheback20 Is that the 4 AWG with a ground? Thank you for the reply bud

    • @doublew030
      @doublew030 2 роки тому

      @@NoneyaTexasontheback20 Sorry for my ignorance. I just want to learn

    • @NoneyaTexasontheback20
      @NoneyaTexasontheback20  2 роки тому +1

      @@doublew030 well again it will depend on 50 or 30 amps Each hot will need to be #4 or #6. Neutral as well if 50 amp. Ground can be size smaller. So #6 or #8 No worries brother that’s why I made vidya 😂👍

    • @NoneyaTexasontheback20
      @NoneyaTexasontheback20  2 роки тому +1

      @@doublew030 I always use copper. And yes AWG

  • @xinli8046
    @xinli8046 2 роки тому +2

    where is your RV park? open for business yet?

  • @wendyhigh3088
    @wendyhigh3088 2 роки тому +2

    We need update on rv park progress...

  • @wendyhigh3088
    @wendyhigh3088 4 роки тому +1

    Dont lack much now.

  • @NorthnSouthHomestead
    @NorthnSouthHomestead 4 роки тому +1

    Cool

  • @HappyPlaceCamping
    @HappyPlaceCamping 4 роки тому +1

    Do you have to have any special certification to do all that wiring? Just curious. That's awesome!

    • @NoneyaTexasontheback20
      @NoneyaTexasontheback20  4 роки тому +4

      Certification?? haaaaahahahahahaha um No......lol
      No I never took an electrical course.
      My dad was electrician for about 40 years I learned a lot. I used to be service engineer for large Equipment supplier. There's not much I haven't worked on. Electrical/Plumbing/HVAC/Construction/Industrial stuff....thanks for watching..... Hint: usually with electrical as soon as you hit the switch, you find out if you were right or wrong..... lol

    • @HappyPlaceCamping
      @HappyPlaceCamping 4 роки тому +1

      @@NoneyaTexasontheback20 LOL that's definitely true

    • @NoneyaTexasontheback20
      @NoneyaTexasontheback20  4 роки тому +6

      @@HappyPlaceCamping I hate electrical.... can't see it. and it will bite you.... I just was not gonna pay a guy $14,000 to run pipe and wire.... That is my problem. I can do all this stuff and refuse to pay outrageous prices to have it done. So it takes me forever lol.... I'm so glad I bit the bullet and had the septic company install the septic system....Its getting close to ready now....just widening the entrance where RV's can actually get in.....Hopefully we can advertise soon. Ready for some payback lol...

    • @lucasdixon1795
      @lucasdixon1795 3 роки тому +1

      @@NoneyaTexasontheback20 how many site did you do and rough time that it took you doing most of it your self?

    • @NoneyaTexasontheback20
      @NoneyaTexasontheback20  3 роки тому +1

      @@lucasdixon1795 I did 5 to start about 2 weeks. I’m adding 10 more now. Yes all myself

  • @swiftdisposalservicesllc3326
    @swiftdisposalservicesllc3326 3 роки тому +2

    What size wire are you running from the panel to each site.

    • @NoneyaTexasontheback20
      @NoneyaTexasontheback20  3 роки тому +1

      #4 copper. About 150 ft. 50 amps

    • @swiftdisposalservicesllc3326
      @swiftdisposalservicesllc3326 2 роки тому +1

      @@NoneyaTexasontheback20 So did you use a 50 amp breaker for the line?

    • @NoneyaTexasontheback20
      @NoneyaTexasontheback20  2 роки тому +1

      @@swiftdisposalservicesllc3326 yes 50 amp supply and 50 amp at post. I know I loose a little but shorts runs it’s been ok so far through summer