  • @JerseyMikeHVAC
    @JerseyMikeHVAC  3 місяці тому +17

    VIDEO CORRECTION: Set multimeter to AMPS not OHMS when checking blower motor draw in Air handler. @ 9:08

    • @PosterityOf1776
      @PosterityOf1776 3 місяці тому

      Thanks for the correction. Can we also use a megahom to check actual resistance?

    • @JerseyMikeHVAC
      @JerseyMikeHVAC  3 місяці тому

      Yes. Jumper Man Tech has a video on that here: ua-cam.com/video/tcidIecZR5c/v-deo.html

  • @Knightransport
    @Knightransport 3 місяці тому +8

    Electrical contractor here, great job this is the best preventative hvac maintanance video!!! Great job!

  • @elgkas9928
    @elgkas9928 3 місяці тому +10

    Mike, great video. It is nice to see what SHOULD happen when annual preventative maintenance is performed. When shops charge less than $100 for a pre season check, we know that most times this does not occur. Your video should be used as a training aid for new and seasoned techs.

    • @JerseyMikeHVAC
      @JerseyMikeHVAC  3 місяці тому +2

      Thanks. yeah, that's an issue. A lot of shops only give 60 minutes for these maintenances, so unfortunately, a lot gets skipped for time.

  • @Kevin-mm6xm
    @Kevin-mm6xm 3 місяці тому +2

    Really good tips but I would suggest that when you remove the disconnect, place it on top of the disconnect box or somewhere you can easily see it. That's a positive guarantee that 240 has been disconnected. Putting it back into the box upside down does disconnect the 240, but maybe you forgot to actually take it out, or you put it back in right-side up, or you just took it in and out several times when checking the system and you can't remember is it in on or in off. Leaving it outside the box in plain sight leaves no room for speculation.

    • @JerseyMikeHVAC
      @JerseyMikeHVAC  3 місяці тому

      I hear ya. I do exactly that when I'm servicing or anything else, but with maintenance I started keeping them in flipped and just testing for power at the contactor before moving on to anything electrical, 1) because I don't want the handle to get wet from hosing off the coil and be wet when I put it back in, and 2) I don't want to risk losing it somehow or stepping on it or whatever by putting it far enough away from the work area to keep it dry.

  • @mxcollin95
    @mxcollin95 Місяць тому +1

    Another excellent and informative video sir! I guarantee the local HVAC companies I’ve hired over the years to check my system never did even a quarter of the things you outlined in this video… 🤔. Thanks for posting! 👍

    • @JerseyMikeHVAC
      @JerseyMikeHVAC  Місяць тому

      Almost always true. But just to be fair, most employers don't give these guys enough time to do it. These guys are run hard. A good tech will still get close, though.

  • @jbroheretoday
    @jbroheretoday 3 місяці тому +5

    Very professional and comprehensive. Appreciate your work. Thank you.

  • @larryprice6321
    @larryprice6321 Місяць тому +1

    Dude , love your video walk through for guys like me who are just getting started

  • @cyclingfan2010
    @cyclingfan2010 3 місяці тому +4

    Great video. I work for a small HVAC company in North East Ohio. I do a lot of maintenance. Currently very busy with AC maintenance. So we offer different levels of service (silver, gold and platinum). Platinum I will clean the evaporator coil with Calgon. Blower wheel pull and clean is an extra $125. Most maintenance I do is a silver which is condenser coil clean with water, pressure/temp check of refrigerant. Indoor temp split and all the electrical checks you described. This is just the way it is at the company I work at.

    • @JerseyMikeHVAC
      @JerseyMikeHVAC  3 місяці тому +2

      First I've heard of tiered maintenance options like that, but I like the idea.

    • @michaelcollins5438
      @michaelcollins5438 3 місяці тому +2

      What are the prices for silver, gold, and platinum?

  • @unabridgeddick6645
    @unabridgeddick6645 Місяць тому +1

    Thanks Mike. My understanding is that self discharging capacitors have a small diode going across 2 terminals.

  • @edwardsmith4693
    @edwardsmith4693 3 місяці тому +2

    My guy Mike !! Excellent video, very thourough and detailed. Your content is extremely good, keep doing your thing. Hands down one of the best hvac channels on here by far 👍🏼👍🏼👍🏼✌🏼✌🏼

  • @u2tipsy
    @u2tipsy 3 місяці тому +3

    Shiny fins👍🏽
    Hands down the best videos for HVAC you will find. Keep them coming maestro!

  • @emoneyblue
    @emoneyblue 3 місяці тому +1

    I had to subscribe because this was by far the BEST video I have found on A/C servicing. Thank you for sharing .

  • @abdelmellouk7080
    @abdelmellouk7080 3 місяці тому +1

    Excellent explanation. Great job. Thank you

  • @ashwinpatel4044
    @ashwinpatel4044 Місяць тому

    Excellent video with detail description

  • @macdirk4
    @macdirk4 3 місяці тому +1

    Excellent video. Thanks for such a detailed process. Wish more people were so thorough. Also thanks for correction on amps vs ohms. Was driving me crazy, lol. Thanks!

  • @migueldominguez7962
    @migueldominguez7962 3 місяці тому +2

    Hey Jersey, great video as always! I love the in depth content and explanation. A job well done. I really appreciate your videos. They are very helpful!!

  • @SeamusDaly-oc3yw
    @SeamusDaly-oc3yw 2 місяці тому +1

    Great video Mike , thank you

  • @sermore77
    @sermore77 Місяць тому +1

    Great Videos Mike

  • @josephNguyen-rx7nd
    @josephNguyen-rx7nd 3 місяці тому +1

    Thanks Mike for device PM 👍 you are professional of the hvac :

  • @newvillage3
    @newvillage3 9 днів тому

    Nicely done.

  • @abrahamlizardo86
    @abrahamlizardo86 3 місяці тому +1

    Amazing explanation brother. Thank you. Perfect video to forward to the next guy

  • @edwardnickerson6149
    @edwardnickerson6149 Місяць тому +1

    Very helpful

  • @mustafaoksum4039
    @mustafaoksum4039 3 місяці тому +2

    Definitely did👍 Thanks Mike for the good advice.

  • @stevencossaboon3237
    @stevencossaboon3237 3 місяці тому +1

    Great video Mike. Thank you for the knowledge.

  • @shanegreen268
    @shanegreen268 3 місяці тому +1

    Thank you for sharing your knowledge.

  • @deanmartin1966
    @deanmartin1966 3 місяці тому +1

    Excellent video. Good info. Thanks for sharing.

  • @thomasfox4513
    @thomasfox4513 3 місяці тому

    AM I BEING DIFFICULT ASK MY MAINTENANCE GUY FOR A CONCISE REPORT OF HIS FINDINGS / MEASUREMENTS?
    This is a beautiful, informed, and clear video. Thank you for sharing. I've long, clear understanding of all the procedures you described, except for using the gages.
    We have been highly satisfied with our installation and annual maintenance, but it's been more than 20 years. Understanding the usable life could be running out, we want to know the paid maintenance is optimal.

    • @JerseyMikeHVAC
      @JerseyMikeHVAC  3 місяці тому

      We put all of our readings right on the maintenance invoice. It's not too much to ask.
      Old system an R-22 system? I would say at this point it's time to mull over whether a significant repair would be worth it at all at this point vs. a new unit. Leakey evap coils are so commonly the reason a lot of these older systems end up getting replaced, and if it's R-22, you're probably going to have to consider both a coil and condenser upgrade to 410A at the least.
      If you're likely to opt for getting a newer unit when the next repair comes, I would say just clean the coils off with water, keep the filters really clean and flush out the drain lines once in a while and just leave it at that until the time to replace comes.

  • @jojonguyencb2647
    @jojonguyencb2647 3 місяці тому +2

    Thanks Mike you really top hvac sir

  • @char0507
    @char0507 3 місяці тому +1

    Great job . Very helpful

  • @tonivorsinsky2427
    @tonivorsinsky2427 3 місяці тому +1

    best !!!

  • @Kevin-mm6xm
    @Kevin-mm6xm 3 місяці тому +1

    Jersey Mike, when you're done fixin the ac, fix me up a nice #13 Italian would ya? Heavy on the prosciuttini and cappacuolo, capiche? Sorry...couldn't help myself..:)

  • @pnajera3938
    @pnajera3938 3 місяці тому +2

    Great video, brotha. Spot on

  • @francorizo
    @francorizo 3 місяці тому +1

    thank you, very good info

  • @izzymoney85
    @izzymoney85 7 днів тому

    Haha yeah take them jumpers off and you cant polish a turd (old units ) mike 😂😂 Great work mike starting following you i like you content brother 👍

  • @EarlHayward
    @EarlHayward 3 місяці тому +1

    Just drain the capacitor with a multimeter (measuring AC voltage) - quick, easy, and safe… Just my two cents, but I am also one of the few that wears CAT 2 rated PPE and EH rated boots stepping out of the house for any work no matter how trivial; and probably the only one with a CAT 4 Arc Flash suit in their truck as well…

    • @JerseyMikeHVAC
      @JerseyMikeHVAC  3 місяці тому

      I have an arc flash suit as well, just not on the truck.

    • @realSamAndrew
      @realSamAndrew 3 місяці тому

      I tried to test this. I charged a capacitor with a 12v battery, then set the meter to Volts DC and watched it drain. It was reeeeeally slow. Is this what I can expect in the field? Would it have made a difference if I set it to AC volts instead?

  • @butlerstouchHVAC
    @butlerstouchHVAC 3 місяці тому +1

    great video🔥

  • @Ogtonyg
    @Ogtonyg 3 місяці тому

    Unless it's a heat pump or there's an issue with cooling most people aren't gonna open up the evaporator coil on a furnace ac. It's 120 degrees in the attic so quick temp drop, blower inspection, and flushing the drain, that's about it. In my opinion I think paying for maintenance isn't really worth it unless you're extremely neglectful toward your system like not changing filters or throwing grass from the mower at the outdoor unit. Keep the filters changed and hose your unit off every so often. Granted a tech might catch something else before it can be a problem, but you could be paying for maintenance for several years before that happens.

    • @JerseyMikeHVAC
      @JerseyMikeHVAC  3 місяці тому

      Totally agree on the evap over the furnace situation. I don't do it unless the unit is older, the blower wheel is caked and the filter changing is obviously neglected. I'll call in for more time to do it then, but I also have the luxury of doing that. But for the evap on an AH, I always try to access it exactly because I know a lot of guys skip it.

    • @Ogtonyg
      @Ogtonyg 3 місяці тому +1

      @@JerseyMikeHVAC True. If I see a coil over 10 years old better believe I'm popping the leak detector on it just to check. 😂

  • @jonathanprim8330
    @jonathanprim8330 3 місяці тому

    Very good video!!!
    You go further than me lol. One question why don’t you check capacitor under load?

    • @JerseyMikeHVAC
      @JerseyMikeHVAC  3 місяці тому +1

      With the math involved in doing it like that, I feel like it's just faster to pull the wires off.

  • @chuckb4375
    @chuckb4375 3 місяці тому

    Excellent and thorough! I have an 'N' evap coil at bottom of downflow stack with "dirty" side *directly* under heat exchanger (only ~1" gap), and "clean" side duct exiting down into difficult access in crawlspace. Aside from disconnecting line set and pulling the darn thing out, how do you cope with that as part of cleaning maintenance? Thanks!

    • @JerseyMikeHVAC
      @JerseyMikeHVAC  3 місяці тому

      I'll take a temperature differential reading before and after the coil, usually putting the "before coil" probe using the high limit switch hole inside of the furnace. Then I'll take an external static pressure reading (return and supply plenums). Both a high ext. static pressure and a temperature differential outside of 18-22 deg is a good indicator the coil may be dirty and restricting airflow.
      Frosting refrigerant lines and long cycles are other indicators.

  • @alexluna6810
    @alexluna6810 3 місяці тому +2

    Thats nice when you don’t have a company that gives you one hour per system

    • @JerseyMikeHVAC
      @JerseyMikeHVAC  3 місяці тому

      Yup. Just said the same thing in another comment.

  • @adampajcz8719
    @adampajcz8719 3 місяці тому

    Well I don't clean the evaporator coil as part of the check nor the blower assembly but your spot on with the rest. I would make corrections in the video not just write in a correction for the new guys. Doing all that how much are you charging for an air conditioning check?

    • @JerseyMikeHVAC
      @JerseyMikeHVAC  3 місяці тому +1

      Unfortunately, UA-cam doesn't allow those kinds of edits to videos. Sucks. As for the blower, I'll clean it off if it's just a light dusting, but pulling it is always extra. Around here the average for maintenance is about $150. Up from about $100 just 4 years ago.

  • @douglasmontgomery6315
    @douglasmontgomery6315 3 місяці тому

    Mike, great video. Do you have or know of a simple one page checklist that has all these checks and their typical readings?

    • @JerseyMikeHVAC
      @JerseyMikeHVAC  3 місяці тому

      Not that I know of. Different parts from different manufacturers can have different typical readings so its hard to come up with a 1 size fits all list.

  • @danielvallejo7140
    @danielvallejo7140 3 місяці тому

    Sad part is i never worked for a company that allowed the time to do a thorough maintenance. Which leads me to my question what would be a reasonable price to pay for something like this?

    • @JerseyMikeHVAC
      @JerseyMikeHVAC  3 місяці тому +1

      I do a 90 minute maintenance for $169.

  • @diyhvacguy
    @diyhvacguy 3 місяці тому

    Hey bro, great video. If you are going to use other channels footage, please check with them first. Good way to get a copyright strike.
    Thanks man

    • @JerseyMikeHVAC
      @JerseyMikeHVAC  3 місяці тому

      Sure. Sorry about that. I can cut that part out if you'd like me to. Or I can link to your video. Just let me know.

  • @fisforfriendship6093
    @fisforfriendship6093 3 місяці тому +1

    dont set multimeter to micro camps thats for small currents under an amp. if your looking for amps 1 or more set it to the proper setting range or risk frying. some meters have a plug saying 10 amps thats where you stick your negative lead into

    • @rob8823
      @rob8823 3 місяці тому

      On most flukes there are 2 expensive fuses you can fry when you flow more than the marked amps depending on milli or 10amp plug. Cheaper than a new meter though. Better than inserting your meter in series with the circuit is using a clamp on meter. Way less disturbing of the existing wiring and safer for you.

  • @carlossaenz4075
    @carlossaenz4075 3 місяці тому

    If everthing is alright what would be the temperature out of ur air coming out of the register . 45, 55, 60

    • @JerseyMikeHVAC
      @JerseyMikeHVAC  3 місяці тому

      It's a moving target and changes with ambient temperatures. But generally it will be 18-22 degrees below room temp.

  • @joshsansone5113
    @joshsansone5113 3 місяці тому

    Is there a best practice for testing the dual run capacitor on condensor? Testing static with unit off and wires removed vs under load capacitor test?

    • @JerseyMikeHVAC
      @JerseyMikeHVAC  3 місяці тому +1

      Just comes down to preference. There's no concrete data proving one method is better than the other. For me, I don't do maintenances often so removing the wires to perform the test isn't as bothersome as someone who might be doing these maintenances all day every day. I also don't like to rely on apps to process data for me, which you need for the load test. I'd rather see it on my meter. I also like to see how secure the wires are, look for corrosion all the way around the cap, etc.
      But that's just me.

    • @joshsansone5113
      @joshsansone5113 3 місяці тому

      @JerseyMikeHVAC great feedback, thank you for your perspective.

  • @Peelerusa
    @Peelerusa 3 місяці тому

    Jersey Mike, thanks for the great turorial.
    Is there a way to determine whether my system is overcharged with refrigerant, without using a gauge set? Are there some signs to look for?
    Thank you.

    • @JerseyMikeHVAC
      @JerseyMikeHVAC  3 місяці тому

      www.townsendtotalenergy.com/overcharged-ac-symptoms

  • @ekie85
    @ekie85 3 місяці тому

    How do you a split up flow???

    • @ekie85
      @ekie85 3 місяці тому

      Cleaning an A coil

    • @JerseyMikeHVAC
      @JerseyMikeHVAC  3 місяці тому

      A lot of disassembly, particularly on furnaces. But sometimes you get lucky by just removing a few screws to remove the front panel.

  • @ivancook1247
    @ivancook1247 3 місяці тому

    Whats the cost of this kind of maintence?

    • @JerseyMikeHVAC
      @JerseyMikeHVAC  3 місяці тому +2

      Depends where you are. Metro NYC probably in the ballpark of $169 for residential, but it can vary a lot. Finding the right tech to do it is more important than the price though.

  • @mikimiki195
    @mikimiki195 3 місяці тому

    Do you have capacitor outside on ac unit and inside on blower motor ?

    • @JerseyMikeHVAC
      @JerseyMikeHVAC  3 місяці тому

      Yes, but not all blower motors on the indoor units have them.

    • @mikimiki195
      @mikimiki195 3 місяці тому

      @@JerseyMikeHVAC can you buy these and save them so when they go bad you have one on hand ? If yes than how long can they just sit on shelf?

    • @JerseyMikeHVAC
      @JerseyMikeHVAC  3 місяці тому +1

      @@mikimiki195 Sure. We keep them on the trucks for stock. They'll last a long while.

    • @mikimiki195
      @mikimiki195 3 місяці тому

      @@JerseyMikeHVAC thank you 🙏🏻

  • @conservativerepublic7224
    @conservativerepublic7224 3 місяці тому +1

    Take the duct off? Haha! No. That's not a maintenance. That's a bunch of extra work. With a bunch of extra cost.

    • @JerseyMikeHVAC
      @JerseyMikeHVAC  3 місяці тому +1

      With most install jobs I've seen out there, it's only like 3 screws.

    • @conservativerepublic7224
      @conservativerepublic7224 3 місяці тому

      @@JerseyMikeHVAC that's pretty bad. Most of the ones I see are sealed with mastic and silver tape. I'm down in Tampa, fl

    • @JerseyMikeHVAC
      @JerseyMikeHVAC  3 місяці тому

      @conservativerepublic7224 Yeah Ill leave it alone if it's a mastic seam and there's no other way.

    • @10forthebigguy753
      @10forthebigguy753 3 місяці тому

      I agree with checking the dirty side of the evaporator coil. The house I bought was a rental run with no filter for 10 years it was filthy.

  • @WhowereEpsteinsclients
    @WhowereEpsteinsclients 3 місяці тому

    Like the world needs another UA-cam Technician. Rather than make these stupid videos start a non profit that gets poor people heating and cooling. Make our industry better not worse.

    • @JerseyMikeHVAC
      @JerseyMikeHVAC  3 місяці тому +2

      Most of the viewers on my channel are other techs who are learning. My videos are aimed at helping them be better technicians. I also help a lot of people for free. I'm not selling anything here. I don't ask people for money. I don't understand how that's making it worse.

    • @WhowereEpsteinsclients
      @WhowereEpsteinsclients 3 місяці тому

      @@JerseyMikeHVAC You are dime a dozen bro. Do something in the industry. All you are doing is making videos for hacks.

    • @JerseyMikeHVAC
      @JerseyMikeHVAC  3 місяці тому +1

      @WhowereEpsteinsclients I'm curious why you didn't bother to reach out and ask if I would be interested in partaking in some non profit or charity you already have up and running. I likely would have been on board with that. This more or less bitter approach isn't working to make anything better in the world.

    • @oilandfireguy1739
      @oilandfireguy1739 3 місяці тому +1

      You sound like a mikey pipes fan 😂😂

    • @WhowereEpsteinsclients
      @WhowereEpsteinsclients 3 місяці тому

      @@oilandfireguy1739 Cant stand that yankee loud mouth.

  • @joemartinez-673
    @joemartinez-673 2 місяці тому +1

    THANKS 🤟😎

  • @macdirk4
    @macdirk4 3 місяці тому +1

    Excellent video. Thanks for such a detailed process. Wish more people were so thorough. Also thanks for correction on amps vs ohms. Was driving me crazy, lol. Thanks!