Philips OB/GYN Ultrasound: How to perform a 3D GYN volume

Поділитися
Вставка
  • Опубліковано 27 сер 2024

КОМЕНТАРІ • 18

  • @rashaalj5927
    @rashaalj5927 2 роки тому

    Cant stop eye tears. Amazing

  • @MrVeer58
    @MrVeer58 2 роки тому

    2D image optimisation and XRES
    In Affiniti 50, XRES is available with at buttons.
    1. Menu button (in the center of the touch screen). only on or off state with selection or de-selection of the button
    2. Softkey button at the bottom of the touch screen. Using the rotatory knob below the soft key, one can adjust it to 1-5 levels.
    Which of these two buttons are to be used for 2D image optimisation for carotid plaque quantification with VL 13-5 Volume probe ?

    • @PhilipsHC
      @PhilipsHC  2 роки тому

      Hello, thanks for reaching out. For any enquiries regarding our Healthcare products, we recommend contacting our Healthcare team directly. You can do so via the link below: to.philips/6053J0f0L. We hope this helps!

  • @MrVeer58
    @MrVeer58 2 роки тому

    Very useful.

    • @PhilipsHC
      @PhilipsHC  2 роки тому

      We're happy to help! Feel free to reach out to us again if we can be of furhter assistance. :)

    • @MrVeer58
      @MrVeer58 2 роки тому

      @@PhilipsHC We are using VL13-5 probe along with our Affiniti 50 US system for Carotid Atheromatous plaque quantification. The Resolution of the image is low in both 2D and 3D modes (much lower than that of L12-3 probe). Therefore, we are having difficulty in carrying out plaque quantification as the plaque is not clearly visible with VL13-5 probe. Please note that the same plaque is clearly visible with L12-3 probe.

    • @MrVeer58
      @MrVeer58 2 роки тому

      This is in continuation of my yesterday's post.
      In Affiniti 50, with VL13-5 probe option, XRES soft key at the bottom with options 1-4 is not available. I am not sure whether this is one of the main reasons for the poor quality of images in 2D and 3D modes with VL13-5 probe.
      Kindly help us in improving the quality of the 3D images with VL13-5 probe.

    • @PhilipsHC
      @PhilipsHC  2 роки тому

      Hello MrVeer58, thank you for getting back to us. Can you please confirm in which country you are located? We will be glad to help you further! 🙂

    • @MrVeer58
      @MrVeer58 2 роки тому

      @@PhilipsHC I am at NIMHANS, Bangalore, India.

  • @MrVeer58
    @MrVeer58 2 роки тому

    We are interested in performing Carotid Atheromatous plaque imaging with our Affiniti 50 US system and VL 13-5 Volume probe. Request information regarding the settings for 2D image optimisation: XRES, Wide scan, SonoCT, Hormonics and AutoSCAN; XRES (1-5), 2D opt (Res or Gen), Res/Spd, Dynamic range (50-60 or at the lower or higher end), Gray map (1-5), Autoscan (db level) and persistence etc; and for 3D optimisation - Angle (15 or 30 degrees).
    Is XRES (1-5) unaviable in 3D imaging?

    • @PhilipsHC
      @PhilipsHC  2 роки тому

      Hi there, for questions related to our Healthcare product we highly recommend you to reach out to our product team specialists. You can do so via the following phone contact: to.philips/6051JHuNR. They will be able to answer all your question and assist you further. :)

    • @MrVeer58
      @MrVeer58 2 роки тому

      @@PhilipsHC Thanks for the reply.
      I am unable to find a helpful link at the above address.

    • @PhilipsHC
      @PhilipsHC  2 роки тому +1

      Thank you for coming back to us MrVeer58. We are sorry that the previous link wasn't exactly what you were looking for and we hope that this form can help you answer your questions.
      to.philips/6055JHdhf
      Please, do not hesitate to contact us if you have any other questions or inquiries.

    • @MrVeer58
      @MrVeer58 2 роки тому

      @@PhilipsHC Is it possible to forward my query to Mrs.Johanna Maack. She should be able answer our query.
      Our main concern is -- if the carotid lumen is too dark, echolucent plaques will be missed. If the lumen is more grey, GI3D and VPQ softwares may overestimate the plaque size / detect plaque(s) when none is present.

    • @PhilipsHC
      @PhilipsHC  2 роки тому

      Hi there, MrVeer58. Yes, it is possible to forward your query. However, to do that we would appreciate it if you could send us your contact details (country of residence and email address) and the product details. We hope to hear from you soon. :)

  • @arthikashetty8214
    @arthikashetty8214 9 місяців тому

    How to curve the roi lune in philips iu22? Is it possible

    • @PhilipsHC
      @PhilipsHC  8 місяців тому

      Hi Arthika, thank you for your question. On the iU22 the trim line can be moved up and down, but you cannot curve the trim line on this model. This function became available with EPIQ and Affiniti. Don't hesitate to reach out if you have any further questions.

  • @sarvejanasukhinobavunthu712
    @sarvejanasukhinobavunthu712 3 роки тому

    But at what cost