बहुत से लोगों के विडियो देखें हैं मैंने, अधिकतर लोगों ने गूगल से फोटो ली और बना दिया बकवास विडियो। आपके विडियो में थ्योरी के साथ प्रेक्टिकल भी है। बहुत बढ़िया जानकारी का विडियो है। Excellent keep it up
Sometimes I visit your channel and get knowledge and illustrations that are very helpful in understanding electrical automation. I am very much thankful to you. You are a genius young boy. May God bless you with health and happiness. take care.
Bhai tu kmaal insaan h... Awesome video. U know what first time I watched seansor video and clear all the doubts related to seansor... Thanks for uploading this important video
Bhai aap ne jo bataya hai . Bahut accha hai. Lekin bhai led on off ki jagah koi magnet bana kar dikhaiye jo kisi lohe ki cheez ko ak inch ki doori se kheech le.
Aap kar skte ho, but not advisable. Kyonki sensor ki ek limit hoti hai load ko chalane ke liye. Zyada load ek saath connect karoge sensor ke saath toh sensor hi kharab ho jaega!
I have a doubt? Can we connect brown and blue wire of the sensor to 220volt AC as on the sensor it's printed to give supply upto 30volt direct current supply. Clearly my doubt.
Hi I have 3 wire sensor fitted back on the motor I have two wires sensor fitted on my other motor wich I want use so which wire which I cant use please help
Please explain how to connect a 12-24 V sensor to a Omron MY2NJ 12 V relay and connect a 220 V AC motor/ pump to switch on and off the pump when desired pressure are reached
Sir 8 Pin rely hai hamare Pass magar uspe likha hai 220 volteg AC and 24 volt dc ab Ham kaise pata kare ki rily 24 volt dc pe chalegi ya 220 bolt ac pe
Bhai jan 12 volt DC to 24 volt DC ka matlab hai keh, yeh coil ka operating voltage hai,,,,,,,,, voltage 12 se 24 volt tak ho to relay kam karega, yani (12 13 14 15 16 17 18 19 20 21 22 23 24 volts) is mein koi bhi voltage ho coil par to relay kam karega ................Ab woh jo 220 volts relay par likhkha hai woh relay ke contacts ka handling voltage hai. Aur load connect karne se pehle yeh pata hona zarori hai ke load kitne volts aur amperes ka hai.
Hi bro i need your help We have ANPR camera 2 wire for input camera trigger 2 wire for output. And i will use 6 volt rellay for camera output connection. If someone knows the connection please help me
It is a visual alert for you to know that the device is not working, if you don't like visual alert you can replace the LED with an audible alert like a buzzer.
Bhai koi aisa timer ya koi bhi electronic item aata hai. Jo time ke hisaab se no nc. Par kaam kre. Pls tell me. Bhai.. jaise ki on krne ke baad nc ya no par kre or time up ke baad band ho jaye .. bina koi supply ke ya supply ke. Mujhe mechanical bhi chlega
Dear sir, Hi,I want to detect 2-5mm hole in MS pipe from 1feet distance.after detection buzzer on after few second make spray paint marking on the hole.please send which sensor and timer relay are perfect.
At startup the motor draws 35 amperes the it drops down to about 10 amperes, so what you need is a relay that can handle 250 volts and maximum 50 amperes just to be on the safe side. I am assuming that you live in a country where you have 250 volts at your wall power outlets.
Connect the blue wire of the sensor to #14 relay point,,,,,Connect the brown wire of the sensor to #5 relay point, connect one more wire to brown wire of the sensor to the "LIVE" phase of AC wall outlet (_make sure it is the "LIVE" phase_). Connect #13 relay point to the "NEUTRAL" phase of AC wall outlet (make sure it is the "NEUTRAL" phase), connect one more wire to #13 relay point to connect the load. Connect #9 relay point to the load to complete the circuit. Make sure the relay's coil operating voltage is 250 volts AC (NOT 12 OR 24 VOLT DC).
For Ordering Sensors, Controllers, Timers, Counter. Buy at Discounted Rates at:
made2automate.com/
(Circuit Diagram also Available for Free)
Bhai mujhe sencer bechana h
Kitana hain apke pass@@yogeshprajapati54920
बहुत से लोगों के विडियो देखें हैं मैंने, अधिकतर लोगों ने गूगल से फोटो ली और बना दिया बकवास विडियो।
आपके विडियो में थ्योरी के साथ प्रेक्टिकल भी है। बहुत बढ़िया जानकारी का विडियो है।
Excellent keep it up
Sometimes I visit your channel and get knowledge and illustrations that are very helpful in understanding electrical automation. I am very much thankful to you. You are a genius young boy. May God bless you with health and happiness. take care.
Chote Bhai kamal ka knowledge h
Industries m beginner h as technician good for them
Excellent explain. Your are a both bada teacher ke jaise boll rahahai. Good explanation. For your sharing video.
Bhai please keep making videos on industrial automation & thank you for sharing knowledge free. It's really very helpful 👍
Sure I will
I watch more vedio about this topic but ur vedio is very different about others and easy to understand.
Thank you
You remind of my younger days , when I was young..keep up with the good job.
😊😊
Bhai tu kmaal insaan h... Awesome video. U know what first time I watched seansor video and clear all the doubts related to seansor... Thanks for uploading this important video
Apka channel logo Bohat hi unique hai alag pehchan 👍
Thank you❤🌹 Bhai asan tarika se samjha diya aisa video abhitak koi nahi banaya.
Goodluck 👍🏻
Very nice 👍💐 explain
Bhai aap ne jo bataya hai . Bahut accha hai. Lekin bhai led on off ki jagah koi magnet bana kar dikhaiye jo kisi lohe ki cheez ko ak inch ki doori se kheech le.
You are really good instructor. Very detailed explanation in easy language. Keep it up.
Thank you,Sir.
i bet that your explanation would have been even more useful to more people had it been in (or subtitled) English
Very true, I have heard this many times:)
Thank you bhai bohot achha video banate rehna I support you👍
Dhanyavaad Sir!
Bahot saheta hui hai isse mujhy...thanks bro
Boss, your way of explanation, owsom....... crystal clear 👍👍👍👍
How to keep the light on permanently? Is it through timer.
Very nice video thank you sir very much
Hii bro, very thanks for the application as needed for everyone, can you please make the same video using load as motor instead of bulb
Very good explained 👏👌👍
U r the best. Very clear explanation
You are good person and good job. may you live long
Thank you Sir for your warm wishes!
Is 4 wire has same color code universally whetehr PNP or Npn since PNP is +ve controlled and non Is negative controlled
I am electrician your details very helpful give full details of PLC
Sure
Bro I have a sensor 4 pin ....how can I know which one is supply and which is NO ,NC.. it's a 90-250v ac
Bhaiya Mera pad galti se 14 pin cord relay order ho gya to kya usmein yah send connection karne se chalega jo number ke sath up connection kiye Hain
Load ka negative relay ke konse number pe connect krte ho
Bhai jo aap ne 5no me live wire lagaya hi oh bulb ke + hai ya _se
Thanks for video bahot badhiya samjaya hai apne
Wow 🤩 great practical explanation 🌟🌟🌟🌟🌟🌟🌟🌟🌟🌟
Thank you ⚡
Bhai super sab kuch aaram se samaj gaya
Goodluck 👍🏻
how to do connection in a three phase output
Bro kya 1hi time pr no nc use kr sakty he?
Bro excellent explanation, very clear.
God bless you..
NO AND NC dono se ak sath kaam le sakte hai kya mtlb 2 relay 1 sencer
Aap kar skte ho, but not advisable.
Kyonki sensor ki ek limit hoti hai load ko chalane ke liye.
Zyada load ek saath connect karoge sensor ke saath toh sensor hi kharab ho jaega!
Yes you can use both wire with load simultaneously
That was really helpful, learnt a lot about the sensors
Good to hear that!
Very good brother....kya vo lamp AC220supply wala tha? If yes to ac kahan se milli ? Relay to DC pe operate krwaya
Yes lamp ac ka hai, relay ko humne dc input and relay ki bhi hoti hai vaah pe AC load ko connect kiya!
Ac, 220 कहा से मिली
@@amitsalat relay ke com. mein 230vac diya hai waha se mila.
please give link for buying this sensor
Bhai Poulter feeder me kaun sa sensor laga hota hai
Thank you for your video
Firefly electric co
Dhaka Bangladesh
Muje 300+ reflector sensor kese conection hoga and powar or network se kese judega pz bataye
सर मेरे cummins generator मे amargansi stop sadaun लिखा araha है न नहीं reset हो रहा हे क्या करे क्या falt हो सकता ही
Great work bro completely understand the concept
Very clearly explained, you're really good in expression...
Thank you! 😃
Very interestingly explained..😊
Hope more will come..
Absolutely:)
bhaiya edable oils ki matra ko sencer kease set karega
Can I use different sensor than photoelectric sensor to control relay ?
Can you help me in My project I unable to complete it I am losing something between
thanks bhai for info , kidar miltha hai 4 wire ka sensor ?
I have a doubt? Can we connect brown and blue wire of the sensor to 220volt AC as on the sensor it's printed to give supply upto 30volt direct current supply. Clearly my doubt.
No Don't ever do this. This sensors works on DC only in the range 10VDC to 30Vdc
Thank you brother best ఇన్ఫర్మేషన్...
Thank you,Sir
Bulb 24v dc ka hai kya pls clarify
Thanks bhai aap ki video achhi lagi
What is the application in industry of NC and NO.
helps in using different switching action
It's so informative...keep it up brother...
Bahut acha video bnaya bhai
24v ac solonide valve controller senser any idea
Thanks bro... very useful information.
Very nice bro
Hi I have 3 wire sensor fitted back on the motor I have two wires sensor fitted on my other motor wich I want use so which wire which I cant use please help
Contact me on : +91- 9625356243 I will guide you personally.
@@made2automate
Hi can you send me your WhatsApp number
Please explain how to connect a 12-24 V sensor to a Omron MY2NJ 12 V relay and connect a 220 V AC motor/ pump to switch on and off the pump when desired pressure are reached
Thank you so much.
Very good explanation brother.
Aik video( oscilloscope using and working)? par banado. Mae saudi arabia se hou.
Love you Bro information with pure details 🙏
Bahut ache dost❤️ keep going on
Thank you:)
Good .ye sanser kitne Ka aata h vo bhi bata Diya karo
Friend how can we find the wires those which related which is phase, which is nutral, ?
In ac any wire can be phase or neutral, while doing connection as I said. For particularly finding which is live and neutral,just use a AC testor
why dont have translation
good dear kindly make vdo on reed switch type
I have already made one: ua-cam.com/video/0oX3qffZ3l0/v-deo.html
Very nice and informative video .
So nice of you
Very helpfully information
Goodluck!
Vfd drive programing or how to work
Lajavab boss nice video 🙏
Bro,can I use PNP for one small dc motor and npn for other dc motor
?
No
Is sencer ke control length kitni meter to hoti Hy plz tell me
Detection distance of 8mm TO 10mm
Can DC load drive be driven that is stepper motor
Not directly with sensor
Output load bulb रेटिंग AC hai or DC
Sir 8 Pin rely hai hamare Pass magar uspe likha hai 220 volteg AC and 24 volt dc ab Ham kaise pata kare ki rily 24 volt dc pe chalegi ya 220 bolt ac pe
Bhai jan 12 volt DC to 24 volt DC ka matlab hai keh, yeh coil ka operating voltage hai,,,,,,,,, voltage 12 se 24 volt tak ho to relay kam karega, yani (12 13 14 15 16 17 18 19 20 21 22 23 24 volts) is mein koi bhi voltage ho coil par to relay kam karega ................Ab woh jo 220 volts relay par likhkha hai woh relay ke contacts ka handling voltage hai. Aur load connect karne se pehle yeh pata hona zarori hai ke load kitne volts aur amperes ka hai.
Please discuss about type of encouder
Thanks you sir , upka video poson hoyga bod bod accha video he
How to know if any sensor has been put in our house by somebody
A sensor is not a surveillance device.
5 wire DO sensor connection k upar video banao kon c wire supply hai or kon c wire signal hai
Hi bro i need your help
We have ANPR camera
2 wire for input camera trigger
2 wire for output.
And i will use 6 volt rellay for camera output connection.
If someone knows the connection please help me
Opto_out_s ( max 10mA)
Opto_out_g ( max 10mA )
Sir , why led glows when fuse goes off in the DCs pannel tb ????
It is a visual alert for you to know that the device is not working, if you don't like visual alert you can replace the LED with an audible alert like a buzzer.
Can you also advice where can we buy the SMPS device shown in demo?
Contact: 9868092093
Need this info but unfortunately dont understand what you are saying.
Aapko bhut achi knowledge ha
Bhai koi aisa timer ya koi bhi electronic item aata hai. Jo time ke hisaab se no nc. Par kaam kre. Pls tell me. Bhai.. jaise ki on krne ke baad nc ya no par kre or time up ke baad band ho jaye .. bina koi supply ke ya supply ke. Mujhe mechanical bhi chlega
Yes aaten hai, but voh electronic timers hoten hai
Mere channel pe timer ki video hai, usse dekhlo...on delay timer
2 wire sensor me long range ka he sir boliye boss.long range chaiye muje
2 wire mai long range nhi hoti!
Sir link u tube link please 2 wire long rengeka sensorka
Sensor hi nhi hota aisa!!!!!
Hello boss video ka link bola mai.
Boss mai bola apka pass 2 wire sensor ka(long range ) video k hai to uska link send kardijiye Bo's...k
Superb job 👍🏻👍🏻
Perfect Explanation .👍
love you sir
you are very great
😄
Please one video make fiber optical sensor and amplifier settings etcc
Good
Clearly understand
Thankvyou
Goodluck
Dear sir,
Hi,I want to detect 2-5mm hole in MS pipe from 1feet distance.after detection buzzer on after few second make spray paint marking on the hole.please send which sensor and timer relay are perfect.
How to connect 12v dc spray pump motor in load. Please reply
At startup the motor draws 35 amperes the it drops down to about 10 amperes, so what you need is a relay that can handle 250 volts and maximum 50 amperes just to be on the safe side. I am assuming that you live in a country where you have 250 volts at your wall power outlets.
Does it has one meter range sensor?
No
Follow me on instagram: @sparrow_automates
Link: instagram.com/sparrow_automates/
Programming ke liye kaisa laptop thik rahega, pls batayen.
How to connect 2 wire 24 DC proximity sensor with plc
Connect the blue wire of the sensor to #14 relay point,,,,,Connect the brown wire of the sensor to #5 relay point, connect one more wire to brown wire of the sensor to the "LIVE" phase of AC wall outlet (_make sure it is the "LIVE" phase_). Connect #13 relay point to the "NEUTRAL" phase of AC wall outlet (make sure it is the "NEUTRAL" phase), connect one more wire to #13 relay point to connect the load. Connect #9 relay point to the load to complete the circuit. Make sure the relay's coil operating voltage is 250 volts AC (NOT 12 OR 24 VOLT DC).
Very informative video ... you cleared all my doubts related to sensors ..thank u rishab bhai....
Goodluck ✌🏻