Step-Back Building | Modelling & Analysis | In Etabs | In English

Поділитися
Вставка
  • Опубліковано 14 гру 2024

КОМЕНТАРІ • 15

  • @ShahzadAli-od9ci
    @ShahzadAli-od9ci 3 місяці тому

    Thank you so much for this course Sir I really appreciate your efforts, the way you have explained things in this course was impressive and enjoyable...

  • @waqaszain6839
    @waqaszain6839 2 місяці тому

    Thank you so much sir for such course. before starting the course i thought i would be so difficult to learn but sir you made it very easy for me to understand. Love from Pakistan :))

    • @JitendraChoubisa
      @JitendraChoubisa  2 місяці тому

      Love to hear this, This kind of comments motivates me to do more.
      Thank you for the appreciation 😊

  • @vishalbgs
    @vishalbgs 5 місяців тому +1

    Nice 👍

  • @BhavinKumar-gt4yi
    @BhavinKumar-gt4yi 12 днів тому

    While defining sesmic load pattern, there are 3 options for time period ,which one we should take, user defined or program calculated in etabs

    • @JitendraChoubisa
      @JitendraChoubisa  12 днів тому

      choose program calculated for easier access
      otherwise time period can be calculated from codal formulaes

    • @BhavinKumar-gt4yi
      @BhavinKumar-gt4yi 12 днів тому

      Project is in Sesmic zone is V ,if i do program calculate is shows less reinforcement in beams and all members pass but when i manually put time period its show more reinforcement also some beams fail in shear stress , Calculated with formula as per dimensions of building i got in Xdir-0.36 and in Ydir-0.45 ,

  • @nikhilsrivastava8544
    @nikhilsrivastava8544 4 місяці тому

    iska agla part nahi hai kya sir ?

    • @JitendraChoubisa
      @JitendraChoubisa  4 місяці тому

      Agla part? design has been done? aap aur kya expect kar rahe ho? Let me know.

    • @nikhilsrivastava8544
      @nikhilsrivastava8544 4 місяці тому

      @@JitendraChoubisa pt of steel kese find kare sir

  • @FaizanKhan-ch7je
    @FaizanKhan-ch7je 4 місяці тому

    How can we remove torsional irregularity from. Such type of structures because in Every floor stifness and masses are already changing kindly explain

    • @JitendraChoubisa
      @JitendraChoubisa  4 місяці тому

      Shear wall must be incorporated to balance the center of mass. Shear wall must be fixed at upper/back side of building.

    • @FaizanKhan-ch7je
      @FaizanKhan-ch7je 4 місяці тому

      @@JitendraChoubisa retaining wall back on each step can serve the purpose of shear wall

    • @JitendraChoubisa
      @JitendraChoubisa  4 місяці тому

      Retaining wall is going to be a different entity from the building. No doubt it is going to support the Backfil but to balancd the mass..the retaining wall must have to be integrated into the frame of building and when you are going do it... it's going to be known with name of shear wall 😅

    • @FaizanKhan-ch7je
      @FaizanKhan-ch7je 4 місяці тому

      @@JitendraChoubisa area in each step increase so it means i have to incorporate shear wall at the lower story