Why S/N is calculated by using formula: 2H/h?

Поділитися
Вставка
  • Опубліковано 27 жов 2024

КОМЕНТАРІ • 33

  • @Harikrishna-ey6jr
    @Harikrishna-ey6jr 2 роки тому

    Excellent explanation chacha

  • @akshaygandharv1971
    @akshaygandharv1971 2 роки тому

    Thanks sir for sharing your valuable information

  • @JayeshPatel-fd6fu
    @JayeshPatel-fd6fu Рік тому

    Nice information sir

  • @neeshugupta479
    @neeshugupta479 2 роки тому

    Very good and Exact explained, thanks sir

  • @RazaKhan-ds8by
    @RazaKhan-ds8by 3 роки тому

    Very nice and clear but in some videos the background music is quite irritating, my suggestion would be to remove them.

  • @rupchandpitekar3772
    @rupchandpitekar3772 2 роки тому

    Thanks for clearity

  • @coachgius
    @coachgius 7 місяців тому

    How do you get H in the first place? Is that from the average value of h?

  • @rajunaikbadhavath3442
    @rajunaikbadhavath3442 3 роки тому

    your videos so useful sir, thanks lot

  • @chanadrababug3562
    @chanadrababug3562 3 роки тому

    Excellent sir ..

  • @MUSMAN-pc6wf
    @MUSMAN-pc6wf 3 роки тому

    Great Sir

  • @meghanamuralid8870
    @meghanamuralid8870 2 роки тому

    Sir, i have a doubt about the limits of LOQ and LOD limits
    i.e., LOQ is 10:1
    LOD is 3:1
    why we should consider these limits why not the other?

  • @krdevyadav
    @krdevyadav 2 роки тому

    Thank u sir this video is very useful

  • @Harikrishna-ey6jr
    @Harikrishna-ey6jr 2 роки тому

    It's mean u have to indicate capital -H2&H2 instead of for noise base line (h2&h2)

  • @vivekprajapati1973
    @vivekprajapati1973 8 місяців тому

    What's the limit of S/N ratio

  • @somnathgite6218
    @somnathgite6218 2 роки тому

    Why validation is required pls explain sir

  • @muhammadsaeedsaeed2900
    @muhammadsaeedsaeed2900 2 роки тому

    Sir download the mechanism for measuring the quantum yield of carbon dots using quinine sulfate as standard please

  • @sudeephalder5077
    @sudeephalder5077 2 роки тому

    Can you please repeat why the 2 factor is there?????

  • @venkatareddyvempati9814
    @venkatareddyvempati9814 3 роки тому

    Sir please take classes on stability study's

  • @pawangupta9871
    @pawangupta9871 3 роки тому

    Sir same doubt here, for example if Run time is 50 minutes and peak eluted 20 minutes.than what is criterea of (h) value .near peak OR take up to 50 minutes .

    • @shivrajgiri92
      @shivrajgiri92 3 роки тому

      It should be over a distance>or = to 5 times width at half height of main peak
      Ex. Main peak height is 50 cm so at 25 cm measure width, suppose it comes 2cm so you take > or = to 10cm on both side of main peak

  • @PKvaghela0111
    @PKvaghela0111 4 роки тому

    Please sir give one lecture on how to select dissolution parameters and dissolution media

  • @chandankondapaka2308
    @chandankondapaka2308 Рік тому

    Is it method 1 or method 2 sir?

  • @PKvaghela0111
    @PKvaghela0111 4 роки тому

    Amazing sir

  • @kumargedela7588
    @kumargedela7588 3 роки тому

    please explain how LOD= 3 x [C]/(S/N), LOQ= 10 x [C]/(S/N)

  • @amritashetty4090
    @amritashetty4090 3 роки тому

    Sir, from which reference book I can learn all this technical concept apart USP?

    • @Ashok_pp
      @Ashok_pp 2 роки тому

      Snyder book for method deve6

  • @ravindramangale3015
    @ravindramangale3015 2 роки тому

    Why calculated s/n

  • @vikaspatil8910
    @vikaspatil8910 2 роки тому

    Limit of detection s n ratio

  • @yalamachandra9720
    @yalamachandra9720 3 роки тому

    👍👍

  • @mohdazeemuddin8353
    @mohdazeemuddin8353 Рік тому

    One example

  • @padaliyapushpak2595
    @padaliyapushpak2595 3 роки тому

    Hplc calibration

  • @krdevyadav
    @krdevyadav 2 роки тому

    Sir want to know during integration of LOQ solution peak in empower what should be start time and end time for baseline noise . Plaese must reply and give me your contact no. I want to talk to you