Compressive strength of concrete Cube test by Digital CTM machine.

Поділитися
Вставка
  • Опубліковано 6 січ 2021
  • Concrete Cube को क्यों और कैसे चेक किया जाता है

КОМЕНТАРІ • 40

  • @sam5754
    @sam5754 8 місяців тому

    Love u Sir from Dubai

  • @amitsarkar760
    @amitsarkar760 3 роки тому +1

    Very nice sir ji . please upload more related video which is more helpful to us.

  • @syedwaseemakram9739
    @syedwaseemakram9739 3 роки тому +1

    After long time a good video
    Post daily good videos Bro

  • @Akash24274
    @Akash24274 3 роки тому +1

    Very good explanation sir 😊😊

  • @Akash24274
    @Akash24274 3 роки тому +1

    Very nice video sir 😊😊

  • @AjayAjay-fs2nr
    @AjayAjay-fs2nr Рік тому

    Sir you explain very well thank you sir✌️✌️🙏🙏

  • @9429221674
    @9429221674 3 роки тому +1

    Very good sir..

  • @mukundkachhot8559
    @mukundkachhot8559 3 роки тому +1

    Fantastic sir

  • @rajkotmetlab9148
    @rajkotmetlab9148 3 роки тому

    nice one sir

  • @believeinyou4213
    @believeinyou4213 3 роки тому +2

    Respect sir

  • @dilipkumaryadav8608
    @dilipkumaryadav8608 3 роки тому +1

    Nice update

  • @pawartechnical4235
    @pawartechnical4235 3 роки тому +1

    Very very thanks sir

  • @dhruvjethva9768
    @dhruvjethva9768 3 роки тому

    Very nice

  • @vinodkumarsaharma1810
    @vinodkumarsaharma1810 2 роки тому

    🙏

  • @rockyprasad817
    @rockyprasad817 3 роки тому

    Good sir

  • @dhruvjethva9768
    @dhruvjethva9768 3 роки тому

    Good

  • @khanfahad93
    @khanfahad93 3 роки тому +1

    Great sir, M25 gives strength of 43N/mm2👍👍

  • @ziauddinkhan9255
    @ziauddinkhan9255 Рік тому +1

    Pls suggest me CTMachine with good quality and accuracy in both way

  • @faultychannel7106
    @faultychannel7106 3 роки тому

    Nice video sir ji
    Sir kahake ke ho aap

  • @pranavnaxane2252
    @pranavnaxane2252 2 роки тому +1

    Sir iss ke baad mein acceptance criteria as per IS CODE. Nahi kartey kya?
    Mujhe thoda doubt hai kya email id mill sakta hai?

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  2 роки тому

      Jarur ,dear acceptance criteria per jald hi video aayega 👍👍

    • @pranavnaxane2252
      @pranavnaxane2252 2 роки тому

      @@rbsinghcivilengineeringaca6777 great sir,
      Cube validation test ( this vedio) and acceptance criteria test k liye seperate samples lene hogey?

  • @nagendraprasadyenne228
    @nagendraprasadyenne228 Рік тому

    Design mix please

  • @ziauddinkhan9255
    @ziauddinkhan9255 Рік тому

    Company name

  • @mohammedarif2368
    @mohammedarif2368 2 роки тому

    How to calculate load reat sir cube and block 400×200×200

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  2 роки тому +1

      Cube :
      Size :- 150 x 150 x 150 mm
      So that Compressive strength = load/ Area
      Area :- Length x width
      150 x 150 mm
      22500 mm2
      And load :- 610 KN
      1kN :- 1000N
      Calculation :- 610 x 1000/22500
      27.11 N/mm2
      Block size :- 400x200x200mm
      Area :- 400x200
      80000 mm2
      Compressive strength :- Load/area
      610 x 1000 /80000
      7.625 N/mm2
      Rate of load CTM machine ka dono ke liye equal hi rahe gaa..

    • @mohammedarif2368
      @mohammedarif2368 2 роки тому

      @@rbsinghcivilengineeringaca6777 sir according bs standard we are use 13.33kn/pr.mint how this reat

    • @mohammedarif2368
      @mohammedarif2368 2 роки тому

      @@rbsinghcivilengineeringaca6777 sir me aap jo fors load dalte hai na jase according bs standard 6.8 pr sec.hai or solid block 400×200×200 us ka 13.33 kn/pr minutes ye kase aata hai plz reply sir tnx

  • @abhinav-tyagi
    @abhinav-tyagi 3 роки тому

    Sir 🙏
    Why we use cube size 15*15*15cm not 20*20*20cm or 10*10*10cm?

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  3 роки тому +1

      The reasons of cube size 150×150x150mm
      1. Smaller dimension cubes are easy in casting , curing & Testing .
      2. For larger dimensions the loading capacity of testing equipment is also expected to be high i.e. Higher cost of Equipment.
      3. And if testing loads are high safety required for people handling equipment are also high & Cube Weight high also..

    • @abhinav-tyagi
      @abhinav-tyagi 3 роки тому +1

      @@rbsinghcivilengineeringaca6777 thanks sir

  • @ershahnawaz220
    @ershahnawaz220 Рік тому +1

    Maximum strength ka bhi koi criteria hota h kya kisi grade ke liye.

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  Рік тому +1

      Actually mein target strength se 15 % Jada tak ja sakta hai but ye kahi Is code mein mention nahi hai dear.

    • @ershahnawaz220
      @ershahnawaz220 Рік тому

      @@rbsinghcivilengineeringaca6777 sir aggregate crushing value test m rate of loading per sec kitna hoga IS code m 40Tonne upto 10 min de rkha h.

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  Рік тому +1

      @@ershahnawaz220 0.0011 ton per second hoga dear..

    • @ershahnawaz220
      @ershahnawaz220 Рік тому

      @@rbsinghcivilengineeringaca6777 40 T = 40*10 =400Kn
      10 min= 600sec
      Rate of loading= 400KN/600sec
      = 0.67Kn/sec
      Sir hamara wala CTM digital nahi h dial wala h.
      Kn m wahi ( 0.67kn/sec) value set karna hoga kya?

    • @stockmarket3108
      @stockmarket3108 5 місяців тому

      Sir isme pace rate range kitna hona chahiye​@@rbsinghcivilengineeringaca6777

  • @RakeshPrajapati-ub2ye
    @RakeshPrajapati-ub2ye Рік тому

    Sir aap ka number mil jayega

  • @deepakray2679
    @deepakray2679 Рік тому

    Cube result 130 % se jyada nhi hona chaiye