Rigol DHO804 fw1.02 hacking - 250MHz bandwidth, 50Mpts, CAN and LIN decoding

Поділитися
Вставка
  • Опубліковано 30 вер 2024
  • 🛍️ Tindie store: www.tindie.com...
    🛠 Tools and kit: / tools-and-kit-77570017
    💬 Discord: / discord
    😎 Ad-free, early access: / theretrochannel
    🔗
    EEVblog forum: www.eevblog.co...
    Minimal ADB and fastboot: androidfilehos...
    rigol_vendor_bin: github.com/zel...
    Adding WiFi: • Adding WiFi to the Rig...
    🔗
    Thanks for watching!

КОМЕНТАРІ • 58

  • @EngineeringAllAround
    @EngineeringAllAround 2 місяці тому +4

    6:27 HUGE ZERO OFFSET no way to calibrate this. This is common problem. Don't change scope model!

    • @EngineeringAllAround
      @EngineeringAllAround 2 місяці тому +1

      From a 0.5% precision instrument, you've converted it to ~2-5%!
      You can compare readings yourself:
      1) check dc offset with no probes connected (you'll be surprised how huge it is)
      2) connect a stable voltage source to all the channels and to a decent multimeter (you'll be surprised to see huge differences across the channels and compared to the multimeter)

    • @TheRetroChannel
      @TheRetroChannel  2 місяці тому +1

      Yeah I noticed this after filming. Doing an auto calibration resolved it and it's been accurate since

    • @EngineeringAllAround
      @EngineeringAllAround 2 місяці тому

      What avg offsets does your scope have now at 1mV vertical?
      Those errors could be hard to notice. What is the dc error now?

    • @TheRetroChannel
      @TheRetroChannel  2 місяці тому

      @sergivaschenko Average offset now is 220uV at 1mV/div

    • @EngineeringAllAround
      @EngineeringAllAround 2 місяці тому +1

      @@TheRetroChannel that's HUGE, my unlocked dho804 (no model change) at 1mV has: -9.5, 24.7, 50.6, -22 uV; at 1V: -14.3, 5.72, -11.3, -5.5 mV

  • @JDW-
    @JDW- 28 днів тому +2

    @TheRetroChannel, I've been reading the comments by @EngineeringAllAround regarding the downside to hacking the DHO804 to a "different model." I myself implemented your older hack which unlocks new capabilities but keeps the DHO804 model the same: ua-cam.com/video/Az9lXMGV_jM/v-deo.html I've not upgraded the firmware, so I don't need a new hack, but it might be good to release another video showing people how to do the "feature unlock" hack on the newest firmware, without changing the scope model, thereby avoiding the disadvantages mentioned by @EngineeringAllAround .

  • @pomonabill220
    @pomonabill220 2 місяці тому +6

    Just received my DHO804 and did your hack! Worked GREAT!
    It now reports a DHO924 with 250MHz BW! Haven't tested it out yet, but wanted to let you know your instructions are flawless!!!
    Thank you.

    • @EngineeringAllAround
      @EngineeringAllAround 2 місяці тому +3

      The issue is in a measurements precision. From a 0.5% precision instrument, you've converted it to ~2-5%!
      You can compare readings yourself:
      1) check dc offset with no probes connected (you'll be surprised how huge it is)
      2) connect a stable voltage source to all the channels and to a decent multimeter (you'll be surprised to see huge differences across the channels and compared to the multimeter)

    • @dayworkhard
      @dayworkhard 29 днів тому +1

      I owned a Dho924s which has more ram installed and hardware components installed comparing to dho804. Though you installed the software of Dho924s, but the probing result might not be accurate.

    • @JDW-
      @JDW- 28 днів тому

      LOL: "Haven't tested it out yet, but... your instructions are flawless!"
      Actually testing your scope will show whether the instructions (and your ability to implement them) are indeed "flawless" or not.

  • @HN-lh9vs
    @HN-lh9vs 12 днів тому

    Could you provide a pointer to the procedure you used to install your launcher? TIA.

  • @svenpetersen1965
    @svenpetersen1965 3 місяці тому +4

    I think, there is also a hack for upgrading the bandwidth etc. for the Rigol 1054. when I have bought my Rigol MSO4024, I had got the license files for upgrading the bandwidth and all the serial protocol decoding as a free extra with it.

    • @TheRetroChannel
      @TheRetroChannel  3 місяці тому +2

      Yeah the 1054 had similar hacks available. But I think rigol started including those features free of charge later in the 1054 lifespan

  • @MrAnon-g7m
    @MrAnon-g7m 4 дні тому

    One question, does this work on the DSO814 ?

  • @melovescotch
    @melovescotch 3 місяці тому +3

    Nice, so much easier to watch this than follow and figure out the forums!

  • @Colin_Ames
    @Colin_Ames 3 місяці тому +2

    Nice! I don’t have one of these ‘scopes, but it’s good to know that if I ever get one I’ll be able to hack it.

  • @MrAnon-g7m
    @MrAnon-g7m 4 дні тому

    Great channel, subbed !

  • @NicksStuff
    @NicksStuff 3 місяці тому +1

    So, is that a persistant hack? Will the scope still believe it's a 900 series model after the next update?

  • @NicksStuff
    @NicksStuff 3 місяці тому +2

    6:07 ...can you retrofit it? Like, has the PCB provisions for the connectors and whatnot?

    • @aaronchamberlain4698
      @aaronchamberlain4698 Місяць тому +2

      Theoretically yes. In eevblog's teardown, you can see the solder point for where the connector pins would go and a few other small SOIC-8 chips. Obviously you'd also need to cut up your chassis for the probe connector so it's a bit of a big ask. But theoretically, it's there.

    • @NicksStuff
      @NicksStuff Місяць тому

      @@aaronchamberlain4698 Thank you

  • @kka10001
    @kka10001 3 місяці тому +1

    Hello Mark, after you did the first upgrade in the first video and all was well, had memory and bandwidth and it worked fine. Mine also worked fine, after updating the firmware to 1.2 all was fine still had memory and bandwidth like in your second video, But after I recalibrated it was all gone and still have 1.2. In your second video after the firmware upgrade to 1.2 never saw you do a calibrate, which on my scope removed the memory and bandwidth. Have you recalibrated after the latest. In short after the firmware upgrade to 1.2, memory and bandwidth still good until I did a calibrate

    • @TheRetroChannel
      @TheRetroChannel  3 місяці тому

      Ah, no I didn't do a calibrate after updating. I probably should do that, it's been a while

  • @hansmoser162
    @hansmoser162 3 місяці тому

    Thats so confusing for a noob with a DHO804...
    For FW 1.01 you need Golang and for FW 1.02 you need ADB?
    Why are you mixing this?

  • @I_love_our_planet
    @I_love_our_planet 15 днів тому

    And i think when you use the pins on the mainboard and connect the LA Hardware it would work 🙂

  • @johne9430
    @johne9430 Місяць тому

    Is there a similar hack for the DHO802? Or the number of ports doesn't matter?

  • @Robert.Czarnik
    @Robert.Czarnik 3 місяці тому

    Many thanks Mark! After watching, I'm looking forward to finally buy that oscilloscope.

  • @PrincipalAudio
    @PrincipalAudio 3 місяці тому +1

    What does the bandwidth option actually unlock if my DHO-804 can already display 250 MHz signals? Does it allow higher zoom? Or is the amplitude more linear (removing software-controlled 70MHz filter)? Just curious. :)

    • @TheRetroChannel
      @TheRetroChannel  3 місяці тому +2

      From memory the max zoom on the 804 is 4ns/div, the hack allows for 2ns. Not sure if there is a software 70MHz filter, I don't have a reliable way to test both configurations. I just like hacking shit

    • @PrincipalAudio
      @PrincipalAudio 3 місяці тому +1

      @@TheRetroChannel Thanks! I suppose the hack is more than the bandwidth limit, so I guess I'm kinda splitting hairs after thinking about it a bit more. Thanks for your reply. Really appreciate it. :)

    • @tonyfremont
      @tonyfremont 2 місяці тому +1

      There is a built in hardware bandwidth limiter that will affect the displayed rise time of very fast signals and act as a low pass filter on frequencies above 70MHz.

    • @PrincipalAudio
      @PrincipalAudio 2 місяці тому

      @@tonyfremont Thanks Tony. Think I'll do the mod if I can. 👌

  • @tullyselengut7185
    @tullyselengut7185 3 місяці тому

    thanks great video would you be able to make a video of how you hack the dp932e to the A version

  • @nickolastd21
    @nickolastd21 3 місяці тому +1

    thanks

  • @EngineeringAllAround
    @EngineeringAllAround 2 місяці тому +2

    From a 0.5% precision instrument, you've converted it to ~2-5%!
    You can compare readings yourself:
    1) check dc offset with no probes connected (you'll be surprised how huge it is)
    2) connect a stable voltage source to all the channels and to a decent multimeter (you'll be surprised to see huge differences across the channels and compared to the multimeter)

  • @simontay4851
    @simontay4851 3 місяці тому

    Is it possible to add the logic analyser hardware to the DHO804 so you can actually use the logic analyser function when hacking the SW to the DHO924?

    • @TheRetroChannel
      @TheRetroChannel  3 місяці тому

      I know some people were looking into it on the eevblog forums, not sure if anyone managed to successfully do it

  • @NeilsNonsense
    @NeilsNonsense 3 місяці тому

    I believe the probes supplied with the DHO804 only rated for 150 MHz? That's why I've only done the option mod for 100 MHz. I was intrigued by the vendor.bin hack though. It would be nice to see a test on a 200 MHz signal.

    • @TheRetroChannel
      @TheRetroChannel  3 місяці тому

      True. I think people have done some tests with the original probes in the eevblog forum. I don't remember the results and finding them in that thread could be a challenge

  • @khomouda
    @khomouda 2 місяці тому

    Hi Mark when I am connected and try to pull I get adb: error: failed to get feature set: device offline what am I doing wrong, thanks

    • @TheRetroChannel
      @TheRetroChannel  2 місяці тому

      Did you see "ADB connected" after typing in the scope IP and port 55555? I'm no expert on using ADB so google or the eevblog forums may be of more help

  • @docpaul
    @docpaul 3 місяці тому

    sweet - will give this a go.

  • @pedrobaco563
    @pedrobaco563 3 місяці тому

    Done! Thanks!

  • @rreigfpv8276
    @rreigfpv8276 3 місяці тому

    El último paso me pone comando no válido y me quedo ahí he probado el resto de opciones y me dice lo mismo, sabrías que puede ser?

  • @tony2707
    @tony2707 3 місяці тому

    Can you reverse back to 804?

    • @TheRetroChannel
      @TheRetroChannel  3 місяці тому +1

      Should be possible by pushing the original vendor.bin file back to the scope

  • @malarkey4441
    @malarkey4441 3 місяці тому

    50Mpts memory depth do not work for me :(

    • @TheRetroChannel
      @TheRetroChannel  3 місяці тому

      Did you change the model to a 924 or use the unlock all options?

  • @scaleartsg
    @scaleartsg 3 місяці тому

    😂

  • @shangrilai1990
    @shangrilai1990 3 місяці тому

    🍪

  • @Gyaan_anant
    @Gyaan_anant 3 місяці тому +1

    when i push vendor.bin it asking that it needs a argument what should i do?

    • @TheRetroChannel
      @TheRetroChannel  3 місяці тому

      Double check you typed it in correctly. Technically 'push' is the argument

    • @Gyaan_anant
      @Gyaan_anant 3 місяці тому

      Sir can you help me to hack my scope personally
      I will pay your fee whatever it will be.

    • @Gyaan_anant
      @Gyaan_anant 3 місяці тому

      Can you help me in hacking, because whatever i did but not able to hack it.i could pay your fee.