220V to 110V | Mga dahilan na hindi galing sa lupa ang isang linya para sa 110V.

Поділитися
Вставка
  • Опубліковано 25 лис 2024

КОМЕНТАРІ •

  • @alfonsoalianza5513
    @alfonsoalianza5513 Рік тому +1

    Ang bansang may 110 na appliances ay mayroon ding 120 volts galing sa power transformer

    • @pinoyelectrical
      @pinoyelectrical  Рік тому +1

      Good question sir. Sa US at Canada, ang nominal voltage nila kapag single phase transformer (split-phase) ay 120/240v at sa three phase (wye connection) ay 120/208v. So , yes sir mayron.

  • @jaypeepardillo3157
    @jaypeepardillo3157 5 місяців тому +1

    may na check ako 220v sa outlet pero isang linya hindi umabot ng 110v to ground pero ang isa 220v pag line to ground.. ang lakas maka ground..papano ngyare yun kung may naka kabit ng ibang wire?

    • @pinoyelectrical
      @pinoyelectrical  5 місяців тому +1

      Ang system dyan sa inyo ay Single Phase 2-wire system (Line to Neutral).

    • @jaypeepardillo3157
      @jaypeepardillo3157 5 місяців тому

      @@pinoyelectrical may ground kasi boss ...diba dpat ang neutral ay may wire din? para bumalik sa source..kaso yun sa lamesa meron ehh yung equipment nmn walang ground...di kaya kumuha ng supply sa neutral tapos ang neutral naka kabit sa ground lalabs nun parehas may kuryente?

    • @pinoyelectrical
      @pinoyelectrical  5 місяців тому

      @@jaypeepardillo3157 ilang wire ba doon sa service entrance? At song equipment ang nangunguryente?

  • @o0oslayero0o97
    @o0oslayero0o97 Рік тому +1

    Sir bakit po may bonding jumper pdin ang neutral at ground na connected sa earth ground?

    • @pinoyelectrical
      @pinoyelectrical  Рік тому

      Yes required ang bonding jumper ng PEC. Para merong continuity at sa ganun kun may ground fault magtrip ang breaker.

  • @donatoanastacio5704
    @donatoanastacio5704 Рік тому +1

    Meron akong ilang pirasong 110v wall outlet, magagamit ko po ba ito sa paglinya para sa 220v?

    • @pinoyelectrical
      @pinoyelectrical  Рік тому

      Pang 110v lang kasi ang rating ng yung wall outlet ay 110V

  • @dhanielathrop3501
    @dhanielathrop3501 9 місяців тому +1

    So do you suppose to get your newtral ground for 110 volt? Can you explain to me how to add the correct way to run 110 volts. Thank you 🙏

    • @pinoyelectrical
      @pinoyelectrical  9 місяців тому

      I have a video with regards to your question. The title is "220 - 110v Paano kumuha ng 110V."

  • @abrahamalegria8904
    @abrahamalegria8904 6 місяців тому

    Ah hindi recommended pero yun ang ginawa ng iba dito may 110 volts naman.. Line to line pa linya nmin dito.

    • @pinoyelectrical
      @pinoyelectrical  6 місяців тому

      Yun . Hindi recommended pero ginawa parin. Ang mangyari ay ginawang daanan ng current ang lupa , na hindi po dapat ayun sa PEC

  • @abrahamalegria8904
    @abrahamalegria8904 6 місяців тому

    Boss ganyan ang ginawa dito sa amin, ok naman ang takbo line to line ang linya namin. Pasok naman yun sa 110volts

    • @pinoyelectrical
      @pinoyelectrical  6 місяців тому

      Hindi pa rin ok yun kasi hindi naman nerecommend ng power provider lalo na sa PEC.

  • @dimz_electric9347
    @dimz_electric9347 Рік тому +1

    Sa Malaysian Country po kaylangan maglagai ng Earth Group para sa protection

    • @pinoyelectrical
      @pinoyelectrical  Рік тому +1

      Yes sir sa PEC din sa atin...nirequired na maglagay ng grounding para sa protection.