Thanks sir Very nice discribe Can we remove only under voltage coil? My ACB frequently tripp ,little power fluctuations.. Power fluctuations mean it's gone under voltage
bhai saheb aapka bohut shukriya explain karne k liye...mere site per ek acb frequently trip hojata hai aur dobara on off karne per fir sahi hojata hai kya issue hosakta hai
Sir Je WBSEDL laine Jany Sy DG Ato start ho jatha hai WBSEDL laine Aany sy DG Ato Bandh nahe hotha hi koi tame 15/20/30/1/hour lagjatha hai Nahi hone PR manul karna parta hai kya fold ho sakta hai Rely kasy test kar
abb ki breaker fault ke baad on nahi ho raha tha coil ko nikalane ke baad bypass on ho raha hain reset kara pahle phir bhi on nahi hua ab bypass chala rahe hain kaya karien
Very informative and nicely explained.
Very informative video. Concepts are very clearly explained in this video. Everything is to the point.
Thank you dear
Very much informative
Thank you dear
Thank you so much for explaining practical sir 🎉
Always welcome
Good information 👍👍 thank you
Thank you dear❤❤❤
Thnks so much sir ,Good explain with practical
Most welcome dear
Mja aa gya jis trh se smjhaya hai
Thank you dear
धन्यवाद सर जी आपने बहुत अच्छा समझाया है।
Most welcome sirji
Sir many many thanks
Many many welcome dear
Very nice explanation.Great work
Thank you dear
🙏🙏
Thanks dear brother
Wellcome dear
Breaker ka solenoid coil reset karne per nahin ho raha hai reset button ka assemble wiring karke dikhaiye
Hii... very well explained 👏...
Can you please tell us about coil resistance of all 3 coils. That would be much helpful
Thank you dear...
Yes you can also check
ua-cam.com/video/ANOWKY_w88g/v-deo.html
Nice 👍
Thank you
Very informative video
Thank you
Sir
Agar aap k words me relay testing ka video mil jaaye to Maza ajaaye
Thank you for this informative video.
Shukria Bhai...
Yeah...sure...
Pahle ke honge but firse detailed video bnaoonga
@@ZahidHussain-wk1zl ji Sir
I really need siprotec
Abb ref,rem,ret
With omicron or severker 900
Sir abb wirering prectical with diagram
Nice
Thanks
Welcome
Thanks sir
Very nice discribe
Can we remove only under voltage coil?
My ACB frequently tripp ,little power fluctuations..
Power fluctuations mean it's gone under voltage
Yes sure,
Similarly vcb breaker work bataiye
Sure dear
Cut👌
Sir please explain auxiliary contact,coil connection details with practical
Tripping ka leya Kon si coil use le ha
bhai saheb aapka bohut shukriya explain karne k liye...mere site per ek acb frequently trip hojata hai aur dobara on off karne per fir sahi hojata hai kya issue hosakta hai
@@nehaljamal2357 sorry for late reply... Please confirm if problem is still exist...
Do you have a video about trip circuit maintenance?
Sir Je WBSEDL laine Jany Sy DG Ato start ho jatha hai WBSEDL laine Aany sy DG Ato Bandh nahe hotha hi koi tame 15/20/30/1/hour lagjatha hai Nahi hone PR manul karna parta hai kya fold ho sakta hai Rely kasy test kar
@@RamnathRoy-e4g aap VMR check karo... Agar PLC installed hai to Program check karo
abb ki breaker fault ke baad on nahi ho raha tha coil ko nikalane ke baad bypass on ho raha hain reset kara pahle phir bhi on nahi hua ab bypass chala rahe hain kaya karien
@@VrBhagwat1988 Bhai breaker UV coil me power ni hone se ACB on ni ho raha tha... Plz check UV voltage, or replace coil then check again
Commanding 3 coils ka resistance value minimum kittine hona chahiye
95-130 ohm
@@ZahidHussain-wk1zl is there a manual with this information?
What are the steps to look for malfunctions in the tripping coils?
Simply check moving rod, coil pick up strength
Kia Surge ki Waja se Bhi Fualt Trip Aata Hai ???
YES, MIGHT BE POSSIBLE
800 Amp Ato Kam Nhi Kartha Hi 15/20/30 Minet koi Time 1 Haur Vi Lagjatha Hi Ato Hony Me
800 Amp ABB Mak Sir Je es Bary Thora Batha thy Acha hotha Sir
Sir ji apke no.kya he
zahid.hussain44@gmail.com
Nice