- 54
- 280 144
Zahid Hussain
Приєднався 30 вер 2011
This channel is for Electrical beginners
Відео
VCB Parts & Testing Procedure (IR, CRM, Timing)
Переглядів 1,5 тис.3 місяці тому
VCB Parts & Testing Procedure (IR, CRM, Timing)
L&T C-Power ACB Under Voltage (UV)coil bypass
Переглядів 1,7 тис.7 місяців тому
L&T C-Power ACB Under Voltage (UV)coil bypass
LT Panel, ACB, Protection release, LSIG
Переглядів 72610 місяців тому
LT Panel, ACB, Protection release, LSIG
WTI OTI Marshalling Box of Transformer
Переглядів 1,4 тис.Рік тому
WTI OTI Marshalling Box of Transformer
New Transformer installation within 8 hours
Переглядів 190Рік тому
New Transformer installation within 8 hours
Transformer's device commissioning with VCB HT Panel...
Переглядів 1,8 тис.Рік тому
Transformer's device commissioning with VCB HT Panel...
Air Circuit Breaker ACB Close/Trip/UV Coils #ABB
Переглядів 7 тис.Рік тому
Air Circuit Breaker ACB Close/Trip/UV Coils #ABB
Potential Transformer/Voltage Transformer/PT/VT Connection in VCB Panel
Переглядів 14 тис.2 роки тому
Potential Transformer/Voltage Transformer/PT/VT Connection in VCB Panel
A glimpse of the training session... #training onsite training... ABB #acb
Переглядів 5862 роки тому
A glimpse of the training session... #training onsite training... ABB #acb
Vacuum Interrupter (Vacuum Bottle) VCB Contact
Переглядів 9 тис.2 роки тому
Vacuum Interrupter (Vacuum Bottle) VCB Contact
Automatic Fire Suppression System in Electrical Panel
Переглядів 9 тис.2 роки тому
Automatic Fire Suppression System in Electrical Panel
Auto Phase Correction Panel replacement project....
Переглядів 1,4 тис.3 роки тому
Auto Phase Correction Panel replacement project....
Sir HT panel ki SLD email krsakte hain ?
@@MuhammadShaheer-qv8nj so sorry dear...
Veri nice sar Dil Se❤🙏💓
@@tarababu9870 Thank you dear💕💕💕💕💕💕💕
Nice vedeo
@@rahulelectric12 thank you❤
Kitna temperature ke bad best hota hai
Hum set karte hain... More than 80 degree
@@ZahidHussain-wk1zlsystem discharge symbol show kr rha hai on krne par Kya problem hai please reply
My breaker not holding after charging manual also
@@TheEJAZ88 check first in rackout conditions
Sir ,Please make a vedio how to uv shunt closing coil, charging motor connection connect.
@@VijayKumar-dg7xf sure dear
Aslam alaikum
Walekum assalam janab
Nice information sir plz upload bypass type videos.
@@amitsingh-cz3fn thank you dear
Good very❤❤❤
@@Cutehaniya18 Thank you Haniya
Sir, Coil uv shunt closing connection kesa or kha pr connect krta ha,spring chaege moter connection kha pr connect hota ha with practical wireing diagram explain sir .
Sir what is the meaning of underroot 3 write on metering cubical pt retio 33000/underroot of 3/110v/underroot of 3 please tell mi
Good question... jab aap PT secondary me LL check karoge then 110VAC ayega if LN then it's 63VAC. isiliye HT RYB ki indication me 63VAC mention hota h...
Ct step up transformer hota hai sie
@ZahidHussain-wk1zl sir voltage badhega to current ghatega,to ct ka use current ko km krne me hi to hota hai na?
@@ZahidHussain-wk1zl ok thanks sir
@@alex-ju6hj Yes bhai you are right... Thank you for your concerns... The total power in a transformer is the same on the primary and secondary sides. The only way to step down the current is by stepping up the voltage. Therefore, a current transformer is a modified step-up voltage transformer
Good information sir
@@chintalakrishna-y2t Thank you❤❤
🎉🎉🎉
👌❣️ Sir, Is there any temperature range of this camera?
@@RohitKumar-ic7ws yes... You can choose in any range till 1200 but much expensive
Good
Thanks
Sir Ek video Partial discharge test kit par
@@archive9994 yeah... Sure
Nice 👍👍👍 thank you sir for the video
@@incredibleindia4156 Thank you Hamid bhai
Sir ji smps ka ek video bana dijie pls
Thank u sir Mai shivam mcn prayagraj
@@shivamkumardubey5049 most welcome dear...
Sir ji ek lt panel control supply ki video share kr dijie
@@ZahidHussain-wk1zl ❤️
@@shivamkumardubey5049 Sure
🙏🙏
This kit can be used for any acb make like Schneider landt?
No, it's only for L&T
Plzz provide details on ground fault
Very informative video.. Thank you sir
Thank you Sachin
Ye to humare palle nahi pada jo samjha rahe hain like banta hai❤❤❤
@@DarakasanZahidi Thank you🙏
Bhut acha explain kiye hai sir ji thank you
@@mdgulamjeelani361 Thank you Gulaam
Well explain sir
@@mdgulamjeelani361 Thank you❤
Bahut acha explain kiye sir ji
TNC jab hum close karta hai bash ush time scdcl power trip karte hai,,, orr kuch kam nehi karta hai,, Kis ka kiya problem hai samaj nehi araha hai.. please help me.
@@etadivlog7120 you need to adjust your relay timing... So that your VCB will trip first in fault condition
Or check VCB timing test, might be VCB poles are not opening/ closing in same time
@ZahidHussain-wk1zl ok
Sir vcb ka schematic diagram kese padhe/samjhe es par Video banaiye
@@harishbhatt4591 great... Sure, I will make
Sir apka cmnt dekha tha qi clinic ki video par Mai waha jane wala hu l5 s1 slip disc h Qi clinic sahi hai ki nahi sir olz rply kro
@@ImranAnsari-su8bm thank you for your comment, Aap please jao or ek session attend kar ke dekho... Jb mai gaya tha to QI ke team shayed trained ni thi but you go and grab your experience by own and let me know too
@@ZahidHussain-wk1zl sir jane mai kuch nhi paisa west na hojaege dar lag rha h 26k 21day ka
@ImranAnsari-su8bm please don't go... Aap local physiotherapist ka session le lo, they charge 200-300/sesson... Or itna research ke baad mujhe smjh aaya ke Disc herniation, Disc buldge and slip disc ke case me bs Tens, Wave heating and Traction he acha h... You can add exercise or yoga too... If you belong to India, please visit CMC Vellore.
Bilkul sahee❤❤❤❤❤
Sahee baat
@@DarakasanZahidi Bht shukriya
Sir bht aaLa ❤
@@AsifKhan-no1gh shukriya dost
Jaldi se adjutment karna nahi chahte ❤❤❤❤
@@DarakasanZahidi True
Timing ka control connection dikhana chahiya ta
Videos are very knowledgeable, thank you sir
Most welcome Ram
Sir good night am Ram Roop, working in RjIL AG3
Great... Keep learning
Sir transformers kee reading kaha se lete h btaa skte ho aap
Kaunsi reading leni h
@@ZahidHussain-wk1zl sir transformers kee jo reading hoti h winding temperature, oil temprature, tap position etc inn sb kee readings hum lt panel se lete hai yaa ht panel se
VERY GOOD AND BRIEF VIDEO . MAY GOD BLESS YOU AJAR TO SPREAD THE KNOWLEDGE.🙏
Thankk yyou so much dear❤
Sahee
Thank you dear
Behter andaz samjhaya
Thank you @Daraksha
Bilkul sahee
Very usefull video thank u sir ji
So nice of you
Most welcome dear
Aapke samjane ka tarika bahut hi badhiya he sir...thank u so much sir...
Most welcome dear... Please share with others
Thank u so much sir for your guidance...
Most welcome dear
Ye sara arrangement india ka hai kya??
Yes, mai India me he hoon
Sir ek full feeder eliminate and control working video daliyaga
Hello sir
Hello dost
Masha Allah... keep it up
Thank you