I’ve tried installing 2 keypads as shown with a Euro46 panel.
The Euro-064, which came with the panel has installed OK as Keypad [00] and works fine.
However, the second keypad is a Eur-068 and this fails to connect to the panel.
Powering it up results in a “Please wait” message.
Pressing “D” for 5 seconds and entering “2000” allows me to assign it to Keypad [01].
However, when I press “A” to save the configuration, the keypad flashes up the Version information and then displays a blank screen, which although illuminated shows no information.
I assumed the Keypad was faulty and had this replaced by the supplier. Unfortunately the replacement does exactly the same.
I've tried removing the power from the panel and doing a clean start, setting it to 2002 Grade 2 but this has had no effect.
It seems unlikely both keypads have the same fault - any advice would be appreciated thanks.
Is it likely the main panel is faulty?
Thanks to watch my video if you repeat same step which I show in this video should work. If not work tried to program single keypad hope this make help
@@seiluk
Thanks for your reply.
I’ve managed to get it to work now. I discovered addresses [01] - [05] were set to [2] - Not Used under the ASSIGN KEYPADS AND READERS menu. Now I’ve set it to [0] - LCD keypads, the second keypad is working.
What language is that your speaking
Sorry you hard to understand My first language is not English I tried to to speak. If you don’t understand very sorry.
I got the PIR same ones
great jod sir
Can the control panel be configured via computer software or can it only be configured from the keyboard?
Is there a way to have the display showing when an area is set ?
You need go to Engineering mode and go system option - site option - system display in here you can set name
@@seiluk tried that but the display goes off once it’s set and the customer doesn’t know it’s set as there’s no indication on the keypad like ‘ area b set etc it’s just blank
@@MrTom1379 ok go to display and keep press no then you see display when set if show no then press D to show yes
@@seiluk thanks will try that