How to Troubleshoot and Repair Lighting Problems

Поділитися
Вставка
  • Опубліковано 26 сер 2024
  • Fluke -A1-II Volt-Alert AC Non-Contact Voltage Tester: Amazon.com: amzn.to/13Tw7CY
    Klein Tools RT250 GFCI Outlet Tester that tests voltage too! LCD Display, Electric Voltage Tester for Standard 3-Wire 120V Electrical Receptacles: Amazon: amzn.to/3IZrHox
    DeWalt Cable Stapler with 2020 NEC 334.30 Securing and Supporting NM Cable: • DeWalt Cable Stapler w...
    IDEAL INDUSTRIES INC. 61-535 Digital Circuit Breaker Finder with Digital Receiver and GFCI Circuit
    Tester: Amazon: amzn.to/3vDiAXH
    Fluke 117 Electricians True RMS Multimeter: Amazon: amzn.to/2MAmA0Y
    IDEAL Industries 61-164 SureTest Circuit Analyzer: Amazon: amzn.to/2De5K3y
    Wago (100) 221-412 (50) 221-413 (25) 221-415 Lever-Nut Assortment Pack: Amazon: amzn.to/2WxqHxC
    Wago (25) 221-412 (25) 221-413 (25) 221-415 Lever-Nut Assortment Pack: Amazon: amzn.to/2HR6rDY
    Wago 221-413 LEVER-NUTS 3 Conductor Compact Splicing Connectors Qty 50: Amazon: amzn.to/2HMeYIr
    Wago 221-412 2-Conductor Compact Splicing Connectors (Pack of 100): Amazon: amzn.to/2Oy3Qzm
    Wago 221-415 LEVER-NUTS 5 Conductor Compact Splicing Connectors Qty 25: Amazon: amzn.to/2JSqNP9
    Leviton GFTR1-3W SmarTest Self-Test SmartlockPro Slim GFCI Tamper-Resistant Receptacle with LED Indicator, 15-Amp, 3-Pack, White: Amazon: amzn.to/2X1Hqtk
    DEWALT XTREME 12V MAX Impact Driver Kit, 1/4-Inch (DCF801F2): Amazon: amzn.to/2Sj1OFU
    VOLTCLAW-12 Nonconductive Electrical Wire Pliers: Amazon: amzn.to/2GtOtbl
    Leviton T5325-WMP M22-Straight Blade Tamper Resistant Duplex Receptacle, 125 V, 15 A, 2 Pole, 3 Wire, 10-Pack White Piece
    DEWALT DCV581H 18/20-Volt MAX Cordless/Corded Wet-Dry Vacuum: Amazon: amzn.to/2IiCJrz
    Leviton GFTR2-W Self-Test SmartlockPro Slim GFCI Tamper-Resistant Receptacle with LED Indicator, Wallplate Included, 20-Amp, White: Amazon: amzn.to/3gj7bzp Leviton GFTR1-W Self-Test SmartlockPro Slim GFCI Tamper-Resistant Receptacle with LED Indicator, Wallplate Included, 15-Amp, White: Amazon: amzn.to/33k1qhj
    Leviton GFTR1-I Self-Test SmartlockPro Slim GFCI Tamper-Resistant Receptacle with LED Indicator, Wallplate Included, 15-Amp, Ivory: Amazon: amzn.to/318g8oG
    Leviton GFWT1-W Self-Test SmartlockPro Slim GFCI Weather-Resistant and Tamper-Resistant Receptacle with LED Indicator, 15-Amp, White: Amazon: amzn.to/39LKyRF
    EATON TRSGF15W Arrow Hart Tamper Resistant Duplex Gfci Receptacle, 125 Vac, 15 A, 2 Pole, 3 Wire, White: Amazon: amzn.to/2CZW8wG
    Leviton DWVAA-1BW Decora Smart Wi-Fi Voice Dimmer with Amazon Alexa Built-in, No Hub Required, 1-Pack, White: Amazon: amzn.to/30VrgFp
    Leviton 5623-2W 20 Amp, 120/277 Volt, Decora Plus Rocker 3-Way AC Quiet Switch, Commercial Grade, White: Amazon: amzn.to/30d9RJG
    Klein Tools MM320KIT Digital Multimeter Electrical Test Kit, Non-Contact Voltage Tester, Receptacle Tester, Carrying Case and Batteries: Amazon: amzn.to/3xiFpQQ
    Klein Tools 80016 Circuit Breaker Finder Tool Kit with Accessories, 2-Piece Set, Includes Cat. No. ET310 and Cat. No. 69411: Amazon: amzn.to/4afXjlI
    Klein Tools ET450 Advanced Circuit Breaker Finder and Wire Tracer Kit for Energized and Non-Energized Breakers, Fuses, and Wires: Amazon: amzn.to/43JgiTA
    Klein Tools 1009 Multi Tool, Wire Stripper, Crimping Tool, Wire Cutter, Long-Nose Multi-Purpose Electrician Tool: Amazon: amzn.to/3TZdOwU
    Klein Tools K1412 Wire Cutter / Wire Stripper, Made in USA, Dual NM Cable Stripper / Cutter Cuts Solid Copper Wire, Strips 12 and 14 AWG Solid Wire
    Amazon Prime Student 6 month Free Trial: amzn.to/2J4txZw
    Audible Gift Membership: amzn.to/31Oxb08
    The video was taken with the: PANASONIC LUMIX GH5 Body 4K Mirrorless Camera, 20.3 Megapixels, Dual I.S. 2.0, 4K 422 10-bit, Full Size HDMI Out, 3 Inch Touch LCD, DC-GH5KBODY (USA Black): Amazon: amzn.to/2VvWVcV and the PANASONIC LUMIX Professional 8-18mm Camera Lens, G LEICA DG VARIO-ELMARIT, F2.8-4.0 ASPH, Mirrorless Micro Four Thirds, H-E08018 (Black): Amazon: amzn.to/2Yem0JO
    Saramonic UwMic9 96-Channel Omnidirectional UHF Wireless Lavalier Microphone System Two Transmitters and One Receiver for Nikon Canon Sony DSLR Cameras, for Video, Field Recording,Interview, ENG, TV: Amazon: amzn.to/2Kc5qWe
    This video was edited with: Cyberlink PowerDirector 19: Amazon: amzn.to/382SH5p
    To make this video I used the ZoMei Z818 Light Weight Heavy Duty Portable Magnesium Aluminium Travel Tripod: Amazon.com: amzn.to/1XOgA5T
    This video was made using the: Transcend 64GB Class 10 SDXC Flash Memory Card (TS64GSDXC10E): amzn.to/1w02Oxn
    Bill and sparkychannel.com are participants in the Amazon Services LLC Associates Program, an affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to Amazon.com

КОМЕНТАРІ • 164

  • @TippyPuddles
    @TippyPuddles 3 роки тому +15

    Thank you for showing how to check the outlet switch. So simple but I'm a "careful" novice. I like to understand everything before I begin. I have power when the switch is in the on position and the live wire is okay too. I'll look at the light fixture next. Didn't want to pull apart the light unless I knew I had to.

  • @JacobPolor-lw2my
    @JacobPolor-lw2my Рік тому +3

    Thanks man! Took the time to comment because I couldn’t get my new light fixture to light up, seen your video and noticed I had 3 wires as well, you said they wire nuts were too small, so I used bigger ones and the fixture lit up!! Thank you

  • @mathman0101
    @mathman0101 3 роки тому +2

    Sparky the world’s greatest teacher on Electrical installations. Those light fittings in particular are not the greatest quality either. Really nice breakdown of the problem troubleshooting.
    Wagos are always the way to go and I have been replacing wire nuts with them as they offer a better quality connections. I would however with stranded cable actually ferrule them before I put them into the wagos and better still use an insulated ferrule to do that. Ferrules add to the solidity of connections in my view reducing the risk of shorting due to cable movement and conductor loosening over time. I think you have done a ferrule video and tools before? Wiha, knipex and ideal do some great tools in this line. I prefer the boot ferrules for a solid even connections.
    On lights more generally this is an area I think manufacturers are very poor on. They tend to produce non-listed items often produced for the cheapest cost with poor quality components with limited manufacturer testing rather than robust UL testing.
    I try to choose UL listed lighting products and fittings for a better safer product but it does limit design choices. As most are non-listed.
    With non-listed light fittings I run quite a few device tests - touch voltage, leakage, earth continuity, insulation resistance. I have an expensive tool to do that and it has been a godsend. With thermal cameras I can also check after installation the current draw and heat dissipation in the box is well within normal safe levels. That also applies to modern LED lights and light strips.
    The power quality issue is also another aspect but I won’t go through that here.
    Good to see your channel building up again I have been praying for your success for one of the nicest guys on UA-cam.

    • @SparkyChannel
      @SparkyChannel  3 роки тому

      Yes, I'm all for higher quality. Even though it costs more up front, the cost will be less over time. And yes, testing before wiring will reveal some dangerous problems from time to time. Thanks!

    • @mathman0101
      @mathman0101 3 роки тому

      @@SparkyChannel Proper grounding is the most important safety aspect. After that I do test both the wiring, switches and the device itself. The device testing as I said requires more specialist equipment even beyond a multifunction tester. In US it’s done specifically more often for medical devices. Take the example of a wall sconce light that would be easily within reach. I prefer to make sure it doesn’t present unsafe touch leakages of currents.

    • @Marcel_Germann
      @Marcel_Germann 3 роки тому

      Ferrules are not necessary for these connectors. Only if you use terminals with a screw. Wago recommends not to use ferrules on this type of connectors, depending on how you crimp them you won‘t be able to insert a larger wire. For example the 221 are rated for 4 or 6sqmm conductors. If you use stranded wires with ferrules you‘ll only get 2.5sqmm in there. The 4sqmm with ferrules won‘t fit through the opening of the connectors.

    • @mathman0101
      @mathman0101 3 роки тому

      @@Marcel_Germann you are correct they are better with screw fittings.
      I would only use ferrules for smaller wires. Even though the 221 has a good AWG range I have noticed that with some finer stranded wire - ferrules did provide a more solid clamp connection than with the wire itself even though the size of the wire in terms of AWG was in the 221 range.
      It wasn’t the batch of 221 I had either I have used several batches. This is especially true for wires for light fittings. For light fittings the wire sizes connections can vary quite a bit even though a wire gauge measurement tool would suggest the 221 would work.

  • @illestofdemall13
    @illestofdemall13 3 роки тому +2

    Hi, Bill, great video as usual. I have another interesting story from last week. A customer wanted an updated LED light and had already taken down the old light, so when we checked the wires at the ceiling fixture box, there was one 14-2 NM cable and by doing some testing with the volt meter we found that the black wire was the neutral, and the white wire was the 120V line and hot all the time. At the switch, there was only one 14-2 NM cable and the black and white were switching the neutral rather than the line. Someone did something weird but we found the connections to be corrected which were in an outlet receptacle box a few feet away. Crazy stuff. Lol

    • @MrFitness94
      @MrFitness94 3 роки тому +1

      I tried to fix a light at my buddies house just like this. Black switched normally like in this video, but white always had 120. I gave up lol

    • @SparkyChannel
      @SparkyChannel  3 роки тому +1

      Wow! Good job on getting that all corrected! It's great that you did the testing before the wiring. Most guys would just plunge ahead and wire it just like the previous guy did. Thanks Kris!

    • @illestofdemall13
      @illestofdemall13 3 роки тому

      @@SparkyChannel There are several things that can be dangerous to assume. One of them is that if the switch is off, then there is no danger of working on it. In this case, the white wire was hot and coming into contact with it and the ground would have been a shock hazard for myself or my boss. Another point to make is I think it's always good to use several forms of testing. The Fluke voltage detector was my first clue that there was a suspicious wiring issue. It did not detect anything on the black, and it did with the white, regardless of switch position. Then I went into more specifics with the volt meter.

    • @illestofdemall13
      @illestofdemall13 3 роки тому

      @@SparkyChannel No problem and thanks. Can't wait for the next video.

    • @SparkyChannel
      @SparkyChannel  3 роки тому +1

      @@illestofdemall13 I've been meaning to ask you: what brand of lighting products do you use or do you shop around?

  • @charger44a
    @charger44a 2 роки тому +1

    A year later and this is the video I needed. Thank you for the step by step troubleshooting.

  • @inadaze813
    @inadaze813 2 роки тому +4

    I wish the company I worked for used those wagos😔 great video sparky

  • @glennlangford5897
    @glennlangford5897 Рік тому +1

    Excellent step by step tutorial! Thanks so much

  • @shaylebennett7310
    @shaylebennett7310 Рік тому +2

    I've been about to cry. I rewired two light switches. There's power to the light but the bulbs won't come on. Im gonna try this. Thank you!!

    • @shaylebennett7310
      @shaylebennett7310 Рік тому +4

      It worked!!! I replaced the twist things and got the clip ones on my garbage disposal AND light.. They both work now! I haven't had a garbage disposal for 5 yrs!!

  • @ccadama
    @ccadama 3 роки тому

    @Sparky Channel. Thanks Bill for another educational video. Great editing, graphics, and explanations. You're really sure of yourself at @04:00. I would've thought you'd test to make sure the light actually worked before putting the glass cover back on. That's confidence on display.
    Hope you and your family stay safe and well.

    • @SparkyChannel
      @SparkyChannel  3 роки тому

      LOL! I knew I had 118+ VAC and that the switch worked. It has to work, doesn't it? You guys stay safe as well!

    • @ccadama
      @ccadama 3 роки тому

      @@SparkyChannel Oh. I see Murphy of Murphy's Law hasn't visited you.
      Hope you and your family stay safe and well.

  • @henryvasquez4152
    @henryvasquez4152 Рік тому +3

    Question, what if thr wires that were connected to the switch didn't read 118 VAC... would that mean there's a problem within the house wiring?

  • @davidharrison9658
    @davidharrison9658 Рік тому +1

    Thank you! This was the most useful information of all the videos I watched.Thank you! Thank you!

    • @SparkyChannel
      @SparkyChannel  Рік тому

      You're very welcome. Thanks David!

    • @LeslieF0330
      @LeslieF0330 26 днів тому

      Same here! Thank you for such a well explained tutorial. You certainly have a skill for teaching sir.

  • @funstuffonthenet5573
    @funstuffonthenet5573 2 роки тому +1

    Very helpful. I suspect my light has an issue like this. As the switch is working fine and the other lights on the circuit work fine

  • @joeking433
    @joeking433 Рік тому +3

    Man, I have a CRAZY circuit! I have two closet switches with lights, lights over the sink, a garage door opener, and 2 GFCI outlets on the circuit. There may be some overhead lights in the garage on it, too. For a while you had to hold the button in to close the door. That has fixed itself recently and now one push will bring down the door. Now a light in the closet wouldn't work but it would flicker if you jiggled the switch. So I replaced the switch and then the closet light worked. But now the closet switch doesn't turn the closet light on, it turns on the lights over the sinks! What is going on???

    • @garyjeffersii6735
      @garyjeffersii6735 Рік тому

      Is any part of that circuit top or bottom switched anywhere? I had something somewhat similar happen once when there was a combination of a loose connection at a receptacle on the non-switched leg and a receptacle that was replaced by the homeowner and they hadn't removed the receptacle tabs for bottom switching. The circuit was shared with the garage and this led to the garage door opener only functioning when the lights in the adjacent room were on. This was because the non-switched leg that should have been feeding the garage was dead. With the tabs not having been removed from that one receptacle, this led to the switched leg feeding power to the garage, but only when the switch was on, of course.

  • @victormendoza6306
    @victormendoza6306 3 роки тому

    Thank you Sparky good to know why light do not work great steps to understand the problem

  • @McmM-ck1op
    @McmM-ck1op 3 роки тому +1

    Bill you do a fine job on everything keep the videos coming...👍

  • @YanajRettun
    @YanajRettun 2 роки тому +1

    I love that you reviewed all your steps at the end

  • @owa2533
    @owa2533 2 роки тому +2

    I want to be an electrician so cool to know these things.

  • @tessjones5987
    @tessjones5987 5 місяців тому

    I grew up in Coronado. Thanks Sparky.

  • @vince6829
    @vince6829 11 днів тому

    Thank you for sharing your knowledge

  • @WeknowCoCo
    @WeknowCoCo 22 дні тому

    Question; How was this working before it the wiring was the problem? Does it cause problems over time? I have this same problem; however, I will not be attempting any of this (LOL). I'm just wondering why the two lights would just stop working after years of working fine.

  • @OtisPlunk
    @OtisPlunk 3 роки тому +1

    I'm sure that Ideal Industries will be happy to hear that Wagos are Ideal. ;-)

  • @debra7449
    @debra7449 Рік тому

    Thank You for showing us this, I don’t really know what the problem is all of a sudden all the lights in my bathroom stopped working, there are 2 switches on the wall, they both control different lights and a ceiling fan in the bathroom, can’t be the light bulbs, there is like 5 of those, it might be the switch on the wall, but I don’t have a device to detect that. I live in an apartment complex, I will have to see if they can come out and see what it is. I already flipped the switch on the breaker box, thinking that might have been it, but it didn’t work. It might be up in the light like you showed us. I don’t know but I need my lights back on, hope they can fix it.

  • @rogertorrez1798
    @rogertorrez1798 3 роки тому +2

    Hi Bill you by any chance make any videos regarding the NEC?

    • @SparkyChannel
      @SparkyChannel  3 роки тому +2

      Here you go: 2020 NEC Video Playlist: ua-cam.com/play/PLSD43kAzjUIR7i0wgM7halOWAxzzZqIje.html

  • @orukalvinklien9518
    @orukalvinklien9518 2 роки тому +1

    Good job man, quite a lesson to learn.

  • @Rogers-Mendez
    @Rogers-Mendez 9 місяців тому +2

    Very helpful video. Thank you sir!

  • @stjabnful
    @stjabnful Рік тому +1

    This was so helpful! Thank you!

  • @conejoyconejamillan3340
    @conejoyconejamillan3340 Рік тому +3

    The right light bulbs make a difference .👍🏽

  • @fsbm7489
    @fsbm7489 2 роки тому

    I greatly Appreciate your wisdom good sir.

  • @rodgerrabbit2955
    @rodgerrabbit2955 2 місяці тому +1

    Good job, sparky...
    Looks like a shoemaker was there before you....

  • @ishrats6341
    @ishrats6341 3 роки тому +1

    thanks for uploading this video my friend. Very helpful.

  • @mernok2001
    @mernok2001 3 роки тому

    So what happened with the ungrounded lamp Bill?Did you run a new ground wire to it or put it on a GFCI curcuit?

  • @shawnie2027
    @shawnie2027 Рік тому

    Wow I so appreciate your knowledgeable video thank you ❤

  • @randee53161
    @randee53161 2 роки тому +2

    why did the light work and what made it stop??

  • @niteraven7333
    @niteraven7333 3 роки тому

    How do I go about finding a break in a wire or wires? We had rain and from what i can tell the light fixture in carport got wet. So now I don't have power in 4 room lights. Outlets work so we can put lamps for now. I was told to do a continuity test, but how do I do this? Can you help please. Thanks

  • @Eddy63
    @Eddy63 3 роки тому

    Good 1 wild Bill ... Very well explained ...

  • @lindamartinez9983
    @lindamartinez9983 2 роки тому +1

    This has been helpful, but I have additional question(s). All of this has been checked. A tester was used to check flow of electricity from connection in the ceiling all the way to the end of the hanging fixture. All is good, except the light bulb does not come on. Changed out several different light bulbs and none work. What else could we try?

    • @AidanSkoyles
      @AidanSkoyles 2 роки тому +1

      try a different light fixture.

    • @lindamartinez9983
      @lindamartinez9983 2 роки тому +1

      @@AidanSkoyles yes. We did that also. Same result, however a curious thing happened. New fixture was removed and old fixture was reattached. It did not work. Five days later, the light came on. So, the new light fixture was reinstalled. Still not working. There is power all the way down to the bulb but bulb does not light. Anything else we could try. And yes, several different bulbs have been tried.

    • @lindamartinez9983
      @lindamartinez9983 2 роки тому

      @@AidanSkoyles I also want you to know that the wall switch that controls this fixture is the same light switch that controls two additional fixtures all at once. Once switch is flipped all lights come on. That’s why it is curious that this light will not work when the other two still do.

    • @gregsewell0
      @gregsewell0 2 роки тому +1

      I've got the same exact light fixture, with the same exact problem. My issue turned out to be a faulty switch that would intermittently work every now and then. I wound up replacing both switches as there were two switches that control that light, and that fixed the issue for me.

  • @Ryuet
    @Ryuet 3 роки тому

    Great explanation, thank you!

  • @garydudgeon
    @garydudgeon 3 роки тому

    Good job Sparky.

  • @jeremiah1797
    @jeremiah1797 7 місяців тому +1

    what those red wires in the back for?

  • @helenkiflu5292
    @helenkiflu5292 3 роки тому +1

    I needed this

  • @davidcunninghamjr6871
    @davidcunninghamjr6871 2 роки тому +2

    Awesome video

  • @Zen_Viniti
    @Zen_Viniti 8 місяців тому

    I have a 3 bulb light fixture in my kitchen and only the middle bulb will turn on and back off once every month or twice a month or once every 2 months, or 6 months etc. It's never consistent. There's no apparent reason or explanation. It's been doing this for the past 5 years since it was first installed. The other 2 bulbs in the fixture turn on and off together like they should when the switch on the wall is turned on and off. The middle bulb only does this when the switch is on and the other two bulbs are on. There's never been any flickering or diming from any of the bulbs and the fixture is mounted sturdy on the ceiling.
    Is there any explanation for this? I'm starting to now think it's just a "ghost" bulb!

  • @nativebluelake
    @nativebluelake 2 роки тому

    Im going to subscribe. You have great informative content.

  • @mikepotter3802
    @mikepotter3802 2 роки тому

    What if I can't get 120V at the switch? I have two 3-way switches to a single fixture but when I pull the switches and look for the hot line wire, I get only low voltage like 40V or so at most.

  • @ramt25
    @ramt25 Рік тому

    Thank you very much!! Fix my problem

  • @GuitarsAndSynths
    @GuitarsAndSynths 8 місяців тому

    I had all six recessed can lights on kitchen ceiling fail at the same time and voltage current from switch is working. Thoughts? How would I find the source of the electrical problem and fix it?

    • @uliperezsatx
      @uliperezsatx 6 місяців тому +1

      It’s in series. So it’s probably the first light.. something is wrong there.start there.

  • @josianrodriguez1249
    @josianrodriguez1249 3 роки тому

    SALUDOS SPARKY ANOTHER GREAT VIDEO.

  • @helenkiflu5292
    @helenkiflu5292 3 роки тому

    I had a quick question. Can you do a video on how to solve a non grounded outlet in detail. Also, how to choose the correct outlet.

    • @SparkyChannel
      @SparkyChannel  3 роки тому

      Hi Helen! This one should help: 2 Prong Receptacle Circuit Replaced by GFCI and Grounded Receptacles per 2020 NEC: ua-cam.com/video/16KObgI44UE/v-deo.html

    • @rubenpinorodriguez5064
      @rubenpinorodriguez5064 3 роки тому

      Excellent, thanks.

    • @helenkiflu5292
      @helenkiflu5292 3 роки тому

      @@SparkyChannel thank you

    • @SparkyChannel
      @SparkyChannel  3 роки тому

      @@rubenpinorodriguez5064 Thanks Ruben!

  • @texas3258
    @texas3258 2 роки тому +1

    I have the same problem I check the switch and it works so I check the light socket and it had power when I turn on the switch but my light bulb won't turn on I've tried different light bulbs any input ?

    • @jamesmc187able
      @jamesmc187able 2 роки тому +2

      It could be the tab on the bottom of the light socket that the bulb makes contact with. With the power off take a small screwdriver and gently lift the tab slightly. Restore power. Install bulb and test

    • @grannyevon9308
      @grannyevon9308 2 роки тому +1

      I have the same problem.I call this person that I know for help! But the person that was suppose to help me act like they didn't know was going on.I CALL THIS PLUMMER CO.CAUSE THEY HAVE ELECTRICIAN THIS PERSON NEVER CALL ME.So then I call someone else for help and made an appt.and that person never show up! So I call them and told them to forget about coming cause they gave me a time frame and never show up! Nor even call me.So then I call someone else and made an appt.with them and I pray they will show up! And fix the problem that I am having.GOD BLESS! PS.NOW THAT I FOUND THIS VIDEO I WILL KEEP IT FOR THE NEXT TIME I WILL NEED IT.

    • @MrTexaz101
      @MrTexaz101 2 роки тому

      Some lights also have the pull cord switch. Endure the you'll cord switch is good. Good luck.

    • @gregsewell0
      @gregsewell0 2 роки тому

      I've got the same exact light fixture, with the same exact problem. My issue turned out to be a faulty switch that would intermittently work every now and then. I wound up replacing both switches as there were two switches that control that light, and that fixed the issue for me.

  • @charlieday5
    @charlieday5 3 роки тому

    Great work

  • @TacticalHandyman
    @TacticalHandyman Рік тому +1

    Nice video thank you

  • @exiled3503
    @exiled3503 Рік тому +1

    Thanks

  • @avillareal1
    @avillareal1 Рік тому

    Help!!! I have 6 LED’s on a 3 way switch, when I turn on from either switch, 5 of the 6 lights start to dim on and immediately dim off. The 6 light stays on as intended. Old work, new problem. Light switches wired tight. Any suggestions?

    • @sherryhowell8697
      @sherryhowell8697 9 місяців тому

      They also made dimmable bulbs for lamps maybe you bought them instead of a regular light bulb good luck

  • @beckyleung7233
    @beckyleung7233 2 роки тому +1

    VERY GOOD

  • @MicheleHuffman-ud9or
    @MicheleHuffman-ud9or Місяць тому

    Some times it will work causes?

  • @cleggydadon
    @cleggydadon 7 місяців тому +2

    how did it ever work if the wires are wrong?.

    • @mpreiss7780
      @mpreiss7780 6 місяців тому +2

      They were not wrong, they were just jammed into a too small of wire connector. I think

    • @seanmoore4653
      @seanmoore4653 4 місяці тому +2

      It maybe worked for a while then stopped because it was a shit connect.. kapeshhhh

  • @robertberin4872
    @robertberin4872 3 роки тому +1

    What if i don't have any voltage at the fixture?

    • @joaquinsuarez6090
      @joaquinsuarez6090 Рік тому

      It could be a bad switch or a bad braker or lose wire connection.

  • @OnTheGoKRO
    @OnTheGoKRO 9 місяців тому

    I have a issue… lol.
    One day My light randomly stops working… (2 light fixtures to one switch! And other one works fine) …. So I disassemble the bulb fixture that isn’t working and test the wires….WIRES are getting power… but bulb isn’t working…SO…I go ahead and buy a new connection where the bulb screws in….
    I Install new bulb connection and install new bulb … STILL NO light on….
    So I check the power and IT has power and correct volt…. But the bulb still isn’t coming on?! Lol.
    -------------
    -So the electric to the fixture is good
    -The bulb connection is hot and good
    - Electricity in the wires are good
    - connections are tight….
    Idk what to do ….
    Could it be the switch?!
    Since two fixtures are tied to 1 switch…. Maybe one of the wires to 1 of the fixtures came lose over time?…….
    Any help would be appreciated. Trying to help my dad here and I’m stuck haha

  • @KnowerofThings
    @KnowerofThings Рік тому +1

    please i got problem i installed new ceiling light and it turns on but it wont turn off! what do i do?

    • @RWCYYT4525
      @RWCYYT4525 Рік тому

      replace the light switch

    • @jeremiah1797
      @jeremiah1797 7 місяців тому

      i had the same problem it was the wires on fixture hook wrong. i had a white and a red hook those up and it work, did you find out what was your problem?

    • @KnowerofThings
      @KnowerofThings 7 місяців тому

      yeah same an electrician came and fixed it in a few minutes . said connected wrong@@jeremiah1797

  • @gfdia35
    @gfdia35 2 роки тому +2

    i have a mind boggling 4 sets of wires going to a garage ceiling box i want to install a simple single bulb light there , why on earth would there be 4 sets ? i know one set is the light switch but when i turn the breaker on the light works but if i hit the switch poof breaker pops ,,,i do not have the money for an electrician , im barely keeping the lights on as it is

    • @jacobmeier8761
      @jacobmeier8761 2 роки тому +2

      The box is serving as a junction, it’s providing power to another box or two elsewhere and or a light most likely. Could be outlets on that circuit, could have been a convenient location to bring the wires to for the person who wired the garage. If the breaker is popping you have a short in the circuit, a hot wire is likely touching ground

    • @gfdia35
      @gfdia35 2 роки тому

      @@jacobmeier8761 thanks your probably right, when I shove the Lil tiny ceramic 1 bulb holding old school style light socket I'm having a hell of a time shoving all that crap back up in the box,,, I'll have to yank it all down and try again,, it's been such a headache I've been putting it off since I left my original comment ☹️

  • @mernok2001
    @mernok2001 3 роки тому

    Do you sometimes get an electric shock Bill?Theres a saying that someone is not a real electrician if he never got zapped.

  • @Reddeadredemption3
    @Reddeadredemption3 5 місяців тому +3

    I have none of this equipment, so I can't even test anything, we had two lights go out in our bedroom and have tried everything to fix them, really don't want to call an electrician out to figure it out bc it's probably something simple

    • @alexcruz3808
      @alexcruz3808 4 місяці тому +1

      Go buy it and figure it out or call an electrician. Real easy to mess up and 💀.

    • @joaquinmaciel2954
      @joaquinmaciel2954 Місяць тому +1

      You ended up calling an electrician huh 😂

  • @nutzatwerk
    @nutzatwerk 2 роки тому +2

    I wish you lived close because it requires a ladder to get to my light fixture and I am old and can’t climb that ladder. Lol

    • @SparkyChannel
      @SparkyChannel  2 роки тому

      Bless you!

    • @lissa01570
      @lissa01570 2 роки тому

      You need a 4 step ladder with handrails like i have. Its like steps, not a ladder. I feel very safe on it.

    • @belettebrave1063
      @belettebrave1063 2 роки тому

      @@SparkyChannel what do you think is wrong with light??…my outlet sparked so now my ceiling fan , light and outlet doesn’t work help plz

  • @JackSparrow-yb3lq
    @JackSparrow-yb3lq Рік тому

    Those wire nuts used are the ones that always come with the fixture.

  • @otunca
    @otunca 2 роки тому

    I need new probs for my aging Fluke meter

  • @nilabmohammad4967
    @nilabmohammad4967 4 місяці тому

    I have electricity coming through but it’s not working 😢😢

  • @terekn2915
    @terekn2915 2 роки тому

    I have the opposite problem. The light stays on and the switch does not do anything. Both white and black wires have current on the switch. 🤔

  • @ryandeeg2538
    @ryandeeg2538 3 роки тому

    No ground wire to connect too

  • @bert1913
    @bert1913 11 місяців тому +1

    Use wago 221's instead of wire nuts

    • @primetime4alifetime747
      @primetime4alifetime747 10 місяців тому +3

      Mf wire nuts work just fine

    • @OnTheGoKRO
      @OnTheGoKRO 9 місяців тому +1

      Frfr lol. Don’t need to change somn that works good for years and years

  • @blacklove804
    @blacklove804 3 роки тому +12

    So I pretty much need to call an electrician. Got it.........

    • @SparkyChannel
      @SparkyChannel  3 роки тому +1

      We're happy to help!

    • @LeslieF0330
      @LeslieF0330 26 днів тому

      Always the best plan for me as well. 😉

    • @wmauibill
      @wmauibill 8 днів тому

      Only if you don’t want to die sir

  • @konamanstudio2447
    @konamanstudio2447 3 роки тому

    🍻🍺👍

  • @djkaneck1
    @djkaneck1 6 місяців тому

    Only seeing 55 volts to the light from switch

    • @SparkyChannel
      @SparkyChannel  6 місяців тому

      Bad connection somewhere? I'd check all terminations.

  • @princenoah21
    @princenoah21 3 роки тому +1

    Why is that homeowner still using CFL bulbs? Aren't LED's more efficient? And is it pronounced "Wahgo" or "Waygo" lever nuts? I'm confused.
    And lastly, I can understand not using deck screws, but why for heaven's sake do companies still make them flathead instead of phillips? My screwdriver ALWAYS slips out of them. :(

    • @SparkyChannel
      @SparkyChannel  3 роки тому

      "Wahgo" is correct. Flathead is old school. :)

    • @princenoah21
      @princenoah21 3 роки тому

      @@SparkyChannel I see. But the flathead is beyond old school. They should be outlawed for any further production BECAUSE they always make screwdrivers slip. Oh, we should be allowed if we want to use what ones we have left, just not make anymore of them. :P
      And why is the homeowner using CFLs instead of LEDs? Aren't they more efficient?

    • @mikevillareal4202
      @mikevillareal4202 2 роки тому

      Flathead slip and phillips strip

    • @princenoah21
      @princenoah21 2 роки тому

      @@mikevillareal4202 I've never had that problem. At least not yet anyway.

  • @markwoel
    @markwoel Рік тому

    Great video - absolutely atrocious description. I'm not sure why you included all of the other crap in your description (I imagine for tagging purposes) but it isn't smart to do that. Trust me. Only include the links that are relevant to your video.