How to install an Outdoor Hot Water Heater.

Поділитися
Вставка
  • Опубліковано 23 січ 2025

КОМЕНТАРІ • 106

  • @ethanalexanderpatience1994
    @ethanalexanderpatience1994 Рік тому +1

    I'd like to say I was xtremely high and watched this video about ten times 🤣🤣 it really helped with my installation

  • @wafiqahcarelse9108
    @wafiqahcarelse9108 4 роки тому +7

    My husband connected our geyser up following this video and it's been 2 months still going without problems thumbs up to the 2 plumber's in the video and I notice they from south Africa by they language lol great jobs

    • @howitsmade5865
      @howitsmade5865 4 роки тому +1

      Thanks for letting us know Wafiqah. Yes, it was filmed in Robertson.

    • @salmaancarelse7443
      @salmaancarelse7443 2 роки тому +2

      I'm the (husband) I see my wife's comment it's been 2 years of the installation of my geyser and I followed every step of this video amazing insight of the procedures no one could believe when I said I did it myself my geyser burst over the weekend but luckily I was insured by outsurance but decided to take a cash claim and do it myself once again because over this 2 years I have installed 8 people geysers and done it brilliantly even if I have to say it myself, pipes was neatly secured to the wall layout was finished perfectly but know I'm looking forward to do mine again but this time I want to install solar panels but I do not think I'll do that myself I'll rather get a professional to do the installation on the solar panels. But after 2years still kept this video in my downloads. Thanks alot guys

    • @salmaancarelse7443
      @salmaancarelse7443 2 роки тому

      @@howitsmade5865 if you can provide me with contact details of your business because I would like to install solar panels to my geyser please

  • @tdyani
    @tdyani 4 роки тому +5

    This is a good job, would’ve loved to hear about the power supply but great job by the guys.

  • @Pyxe_ZA
    @Pyxe_ZA 4 роки тому +2

    Very helpful and to the point. Some of these “how to” videos tend to spend 9/10 minutes talking a lot of nonsense and the actual video is just a minute long. Good job and thanks for sharing

  • @tinashel.gadzikwa4358
    @tinashel.gadzikwa4358 4 роки тому +19

    Good video. However it is important to note that when installing a geyser, there is need to balance the pressure on the cold water supply i.e. cold water for the rest of the house and for the geyser supply.
    To achieve this, cold water supply to the rest of the house must be connected after the pressure valve. So its pressure valve, tee junction (house cold water supply and geyser cold water supply) and straight valve
    Now if you do that you achieve a balanced water pressure on both cold and hot water. Thank you

    • @alexagyeimensah1316
      @alexagyeimensah1316 4 роки тому

      Thanks Tinashe, I'm a plumber can I please have your contact
      My contact is 0786959211

    • @tinashel.gadzikwa4358
      @tinashel.gadzikwa4358 4 роки тому +1

      @@alexagyeimensah1316 in which town are you

    • @alexagyeimensah1316
      @alexagyeimensah1316 4 роки тому +1

      I'm in cape Town

    • @caiphus08
      @caiphus08 3 роки тому

      Except there's no longer cold water supply to the rest of the house

    • @ShaielC
      @ShaielC 2 роки тому +1

      The problem with this is if there is a problem with the geyser, there will be no water at all to the whole house

  • @derickvilakazi2263
    @derickvilakazi2263 8 місяців тому

    The best teacher❤❤❤❤❤❤❤❤❤

  • @jvandervyver
    @jvandervyver 4 роки тому +16

    Why are the vacuum breakers being referred to as solar outlets?
    Also the anti-syphon loop is sitting lower than the top of the "water heater", it should stick out above.

    • @matto6195
      @matto6195 3 роки тому +2

      Handy Andy trying to plumb

    • @adamokuhle9753
      @adamokuhle9753 10 місяців тому

      Looking for this very same comment 😂

    • @ontlametsez
      @ontlametsez Місяць тому

      I also wanted to comment about the anti syphon loop. It should be slightly above the geyser

  • @njabulohonwana3838
    @njabulohonwana3838 3 роки тому +1

    What a greatest content for DIY... just watched this vid and then subscribe to the channel 💯.. hoping to learn much from you

  • @nkem5908
    @nkem5908 3 роки тому

    Job well done guys

  • @trevorelgram846
    @trevorelgram846 Рік тому

    If my tank is fitted underneath my bath ceiling the two vacume green breakers do these have to be installed if fitted horizontally

  • @liampringle2673
    @liampringle2673 4 роки тому +2

    How do you clean the pressure valve cartridge behind the geyser tank? There is no syphon loop on this install?

    • @njongomatole6037
      @njongomatole6037 2 роки тому

      You have little knowledge man do you know that the Vacuum breakers can also works as anty

  • @jay-peephillips2349
    @jay-peephillips2349 Рік тому +1

    THE BRUIN OU, IS THE MAIN OU!!! 💪💪💪 KUDOS TO THESE OU'S, THEY ARE YSTERS IRON🛠️🔩⚙️

  • @pietersmith1441
    @pietersmith1441 3 роки тому +1

    well done for trying all plumbing systems need to be balance otherwise warranty will be avoided on all plumbing mixers

  • @noncebamthembu4415
    @noncebamthembu4415 2 місяці тому

    Hi can I install my geyser in the bathroom instead of putting it in the ceiling ?🙂

    • @ontlametsez
      @ontlametsez Місяць тому

      You can put it outside the house

  • @nsilayenja
    @nsilayenja 2 місяці тому

    These guys just saved me 3200 rands on labor, I called my friend, we did it and bought booe and meat for braai

    • @DiyMoviesSA
      @DiyMoviesSA  2 місяці тому

      Excellent, well done 😊🌈

  • @otherman2958
    @otherman2958 3 роки тому +1

    I have a 600kpa gyser but the pressure control valve of the cold water inlet to the geyser is 200kpa. Can that be the reason I get low pressure on all the hot water taps around the house? Thanks in advance

    • @Hopkinz712
      @Hopkinz712 4 місяці тому

      Tomorrow it will be a void issue Baba

  • @mikethesparky4000
    @mikethesparky4000 4 роки тому +2

    Just a question why do you put ptfe tap around the ring of a copper pipe. Didn't think you needed to do that

    • @bekkiebeans6004
      @bekkiebeans6004 3 роки тому

      You are right, ptfe tape is not required around the rings for that type of fitting

    • @njongomatole6037
      @njongomatole6037 2 роки тому +2

      It is required but it's not a must but wise plumbers they like to do things ones so it ensures that your fittings will never leak due maybe to the faulty on the rings

    • @diasporanbuildingahomeinzi9622
      @diasporanbuildingahomeinzi9622 3 місяці тому

      Can l install on top of the roof?

  • @petrosmzomuhle2755
    @petrosmzomuhle2755 4 роки тому

    very helpful

  • @motswadiwamonna3880
    @motswadiwamonna3880 4 роки тому

    I am learning from you guys, thanks a lot.

  • @matto6195
    @matto6195 3 роки тому +7

    Those "solar outlets" are called vacuum breakers. They allow air into the system and play a role in preventing back siphonage. The anti siphon loop in this installation is too low, the horizontal run of the pipe should be higher then the top of the geyser. The cold water supply to the rest of the house seems to be absent... That would normally come after the PRV to ensure balanced pressure in the installation. Sheesh. Guys please call a plumber instead.

  • @yosslainarthur3153
    @yosslainarthur3153 Рік тому

    Super

  • @FoolyLiving
    @FoolyLiving 3 роки тому

    Why not on the roof where it can get full sun?

  • @caiphus08
    @caiphus08 3 роки тому +4

    I'm confused. You cut the cold water supply pipe and fit it to the inlet of the geyser as well as the outlet? You just changed water supply to the house to only hot water I think. Plus there's no syphon loop on this installation...

    • @nkhumelenimangale4260
      @nkhumelenimangale4260 2 роки тому +1

      I thought I didn't know my story until I read your comment. The must he a Tee after pressure valve so the water can be balanced in the house.

  • @gemi1164
    @gemi1164 2 роки тому

    My geyser was ook buite, totdat diewe die koper fittings kom afbreek het. Volgende keer elektifiseer ek dit.

  • @christophernaicker4464
    @christophernaicker4464 3 місяці тому

    Ahh copper pipes, if only they werent stolen so often in SA would be nice😢

  • @mrivormentoor2788
    @mrivormentoor2788 4 роки тому

    Helpfull very

  • @african3974
    @african3974 22 дні тому

    No job, I MEAN NO JOB... is fully complete without HAASY.... in coloured lingo.... DAAR IS HY... SHORTERNED HAASY.....
    Thanks gents ❤ from PE

  • @sandilevgina1392
    @sandilevgina1392 4 роки тому

    What if I have low pressure on cold water going to geyser?

    • @njongomatole6037
      @njongomatole6037 2 роки тому

      That can result to the burn on your element so you need to install the booster pump to make sure your water supply is active

  • @SpottedEagleOwls
    @SpottedEagleOwls 2 роки тому

    Why must a vacuum breaker installed higher than 300mm above geyser

    • @njongomatole6037
      @njongomatole6037 2 роки тому

      Not higher than that but from the Tee 30cm exactly

  • @aurethlouw8274
    @aurethlouw8274 3 роки тому +3

    Please, teach that bloke to use a copper cutter 😅

  • @jabulanemaphaphu8211
    @jabulanemaphaphu8211 4 роки тому

    How do I empty the geyser, same one as that.,......laymen terms please

    • @philipjooste9075
      @philipjooste9075 4 роки тому

      Maybe you've found it by now but you do that by opening the drain cock on the cold side. If there is not vacuum breaker on the hot side it might no drain easily or at all. In this case remove the safety valve or loosen the hot outlet to "break the vacuum"

  • @richardduplessis3023
    @richardduplessis3023 4 роки тому +2

    Next time mention the pressure valve on the hot outlet side.Mention also that there must be a 30 amp external breaker box .Otherwise good clip

  • @princemazibuko6830
    @princemazibuko6830 2 роки тому

    So why they putting ptfe

  • @charlium
    @charlium 5 років тому

    Very helpful👌

  • @Visionery1
    @Visionery1 3 роки тому +1

    Years ago we spent some time in Montagu during August when outside temps were around 6 degrees, they also had their geyser outside, needless to say the geyser was on 24/7 trying to heat the water to 75 degrees. It would be interesting to see the consumption for the above installation.

  • @liandraprinsloo6670
    @liandraprinsloo6670 4 роки тому +1

    I now you are in South Africa

  • @ebrahimgamieldien8
    @ebrahimgamieldien8 4 роки тому

    Where is the cold water supply to the rest of the house ? Isn't that missing here. Cause the geyser was connected from the main water supply

    • @randellouw7940
      @randellouw7940 3 роки тому

      I was watching this video last night and something bothered me about this, i watched again and saw that there is no cold water supply to the house, so im not sure why they didnt do it like that, would love to know

    • @justineaves4397
      @justineaves4397 3 роки тому

      The system is unbalanced this is the reason for no cold water supply and also they never installed a non return valve to prevent back flow into the system.

  • @johnnysowden2924
    @johnnysowden2924 Рік тому +1

    the narator does not know what is going on here, kwikot geyser are old school and need to be updated, solar instlation is not shown in this video, the presure valve should be instlalled at the water meter side to alow the cold and hot water to have the same presure.

  • @hendrikcoetser9853
    @hendrikcoetser9853 11 місяців тому

    Antisyphon loop t piece must be 100mm obove the geyser this one to low

  • @xolanimthethwa4149
    @xolanimthethwa4149 Рік тому

    This piping is so wrong, using PTFE on ring's on conex fittings 😢😢

  • @myjames48
    @myjames48 Рік тому +1

    No need for ptfe tape on those fittngs with a ring. It is actually a sealing ring. Does not need tape. 😢😢😢

  • @rolandburisch9489
    @rolandburisch9489 3 роки тому

    Good video but perhaps don't include each and every joint being tightened, very repetitive and pointless. I also would have liked to have seen something about the electrical supply requirements.

  • @justinhall7489
    @justinhall7489 4 роки тому +2

    It's a vacume breaker not for solar man

  • @andrewg.mvisser5027
    @andrewg.mvisser5027 3 роки тому +5

    As per SANS this is a bust. Installing a geyser DIY can lead to serious harm.

    • @thunderstorm6616
      @thunderstorm6616 2 роки тому +2

      Most Diy guys do it better than qualified plumbers

    • @capechronicler
      @capechronicler Рік тому

      @@thunderstorm6616 True, but you're insurance company won't view it that way if you can't produce a certificate if it bursts and floods your house.

    • @Princemazibuko664
      @Princemazibuko664 Місяць тому

      ​@@thunderstorm6616well it's not about who does better, but experienced! Qualified plumber follow the instructions and never cut corners, and once he/she has an experience in the trade you can't do better than an experienced person

  • @patricksteytler7342
    @patricksteytler7342 2 роки тому +1

    There goes some profit because nobody knows how to bend

  • @JohannSchreuder-i9y
    @JohannSchreuder-i9y Місяць тому

    You guys did it wrong.. the siphon loop is wrong on cold and more problems here.

  • @bandahazel8803
    @bandahazel8803 2 роки тому

    There not plumbers those dude how can take 2 minutes to cut a pipes? No t for balance water, vacuum valve is for the air

  • @nurruddeen_87
    @nurruddeen_87 3 роки тому +1

    unbalanced system. Your cold water to supply the house should be after your PCV.

  • @patricksteytler7342
    @patricksteytler7342 2 роки тому

    Non compliant. No anti syphon loop.

  • @Yesterdie02
    @Yesterdie02 3 роки тому +2

    It’s a freaking compression fitting ! Wtf would need ptfe tape over that for ! This is a really poor video of plumbing techniques and practice . De burring the pipe is the term FYI sies Julie 😜

  • @Hopkinz712
    @Hopkinz712 4 місяці тому

    Unbalanced water pressure system
    No NRV
    No bonding lug
    GGN required

  • @CosmasNgidi
    @CosmasNgidi 5 місяців тому

    Houmush

  • @wafiqahcarelse9108
    @wafiqahcarelse9108 4 роки тому

    Who ever dislike this video has seriouse problems better then this must be wrong

    • @tinashel.gadzikwa4358
      @tinashel.gadzikwa4358 4 роки тому +1

      Good video. However it is important to note that when installing a geyser, there is need to balance the pressure on the cold water supply i.e. cold water for the rest of the house and for the geyser supply.
      To achieve this, cold water supply to the rest of the house must be connected after the pressure valve. So its pressure valve, tee junction (house cold water supply and geyser cold water supply) and straight valve
      Now if you do that you achieve a balanced water pressure on both cold and hot water. Thank you

    • @randellouw7940
      @randellouw7940 3 роки тому +1

      There is just a slight problem with the installation, no cold water supply to the house

    • @justineaves4397
      @justineaves4397 3 роки тому +1

      It's not completely wrong but as a plumber I have to say it's not a proper installation

    • @matto6195
      @matto6195 3 роки тому +1

      Anti siphon loop not high enough. No cold water supply to the rest of the house after the prv.

    • @patricksteytler7342
      @patricksteytler7342 2 роки тому

      Wy