Single phase motor wiring with 2 capacity-reverse and forward

Поділитися
Вставка
  • Опубліковано 22 бер 2021
  • t.me/hamster_komBat_bot/start...
    Two reasons for adding capacitors to single-phase motor.
    1- In the original structure , the main coil and the auxiliary coil are powered at the same time and the same electromagnetic force is generated to cancel each other ,and the rotor can not rotate.
    2- to make the magnetic field force rotate , it can be achieved by passing alternating current current of different phase sequences in the main coil and the auxiliary coil .
    the existence of the coil capacitor fulfills this function.
    when the motor accelerates to a certain value, the centrifugal switch is disconnected, and the motor runs at the rated speed.
    three phase content: ua-cam.com/users/playlist?list...
    single phase content: ua-cam.com/users/playlist?list...
    others: ua-cam.com/users/playlist?list...
    #single_phase_motor #reverse_forward_with_capacity
    more video:
    how to test and replace coil?
    • Shorted Contactor Coil...
    music link:
    A Newborn Technology For Good by MusicLFiles
    Link: filmmusic.io/song/7295-a-newb...
    License: filmmusic.io/standard-license

КОМЕНТАРІ • 64

  • @virasanaat8269
    @virasanaat8269  2 роки тому +5

    If you have any questions about this tutorial, ask me

    • @saoudi1142
      @saoudi1142 2 роки тому

      Thanks for your sciences serving.
      Please, answer me about two capacities calculations and there relationships with motor power.

    • @elviecarcha7332
      @elviecarcha7332 Рік тому

      My problem is how to install plug in my electric motor,

    • @elviecarcha7332
      @elviecarcha7332 Рік тому

      How to install plug in my motor

    • @virasanaat8269
      @virasanaat8269  Рік тому

      @@elviecarcha7332 3:49
      Click on the time I explained plug in here.

    • @drewjbx228
      @drewjbx228 Рік тому

      @@saoudi1142 Thanks for this info, however I have a 220 motor... Can I use a 2Pole MCB switch and just run 1 live and 1 neutral? But for the live wire do I use just single 110v line?

  • @NicholasHoffmann1
    @NicholasHoffmann1 9 місяців тому +1

    Appreciate the video, had a client that brought in a high pressure water cleaner and it was just humming, turned out the starter cap was wired between V2 and U2. This video helped me fix that.
    Also, the wires were named W1 and W2 instead of Z1 and Z2, but otherwise worked flawlessly.

  • @raduturlea8422
    @raduturlea8422 Місяць тому

    Perfect de bine explicat.

  • @javiertovar2614
    @javiertovar2614 4 місяці тому +1

    excelente video te felicito

  • @alexnemeth3832
    @alexnemeth3832 Рік тому

    Király videó!😃 Le a kalappal!!❤️

  • @user-jn9xh8rf4i
    @user-jn9xh8rf4i 3 роки тому +1

    خیلی جالبه این مدل آموزشتون 👌👌☘🌹🌷

  • @EnglishwithElham
    @EnglishwithElham 3 роки тому

    عالی👏👏👏 تا آخر دیدم

  • @limkeng3963
    @limkeng3963 Рік тому

    Excellent thanks 👍👍👍

  • @HaashimAboobakuru
    @HaashimAboobakuru Рік тому

    Can i heve universal rotary change over swtch diagram single phase

  • @cookinghome5066
    @cookinghome5066 3 роки тому

    بسیار عالی

  • @madankeleng7987
    @madankeleng7987 2 роки тому

    Thanks bro. Good job

  • @sahelfood5759
    @sahelfood5759 2 роки тому

    عالی، خدا قوت

  • @javiertovar2614
    @javiertovar2614 4 місяці тому

    Buenos dís tengo un motor con la misma conexion pero no se valor de condensadores
    En la placa me dice 4hp 300 microfaradios en 220v

  • @chrishouse6924
    @chrishouse6924 Рік тому

    Excellent vid. any vids on how to do two speed single phase reversing motor?

    • @WorryNot-ep8ci
      @WorryNot-ep8ci 23 дні тому

      Just interchange the Terminal U2 and U1

  • @louielawrenceramos87
    @louielawrenceramos87 2 роки тому +1

    any videos for forward,.

  • @Genesis161007
    @Genesis161007 2 роки тому

    Thank you for the video. Could you please show me with that same diagram How to connect the reverse and Forward switch please. Have purchased a single phase motor with two capacitors for my old lathe. Have forward & reverse single wires to connect into this wiring diagram. Thank you

    • @virasanaat8269
      @virasanaat8269  2 роки тому +1

      hi my dear friend. you have to connect v1 to u1 and u2 to v1 for forward direction.
      i will publish a video for you soon.

    • @virasanaat8269
      @virasanaat8269  2 роки тому +1

      In electric motors with temporary capacitors in the circuit and two capacitors that have a remote function switch, it is not possible to turn left and right quickly because the centrifugal switch has changed its position in normal motor operation and the starter coil and capacitor have been removed from the circuit. To change the direction of rotation of the motor, the motor shaft speed must be reduced to less than one third of the nominal motor speed and the key of the speed function must be returned to the original state, then the motor must be connected to the power supply.

    • @vaidaccc
      @vaidaccc 2 роки тому +2

      @@virasanaat8269 v1u1 and u2v1 ??? its short circuit? I think you make mistake?

  • @shadibagheri2562
    @shadibagheri2562 2 роки тому

    👏👏

  • @tibortoth186
    @tibortoth186 5 місяців тому

    Azt az eggyet nem tudom az ilyen videókba miért nem lehet azzal kezdeni hogy elmagyarázza mit jelent az U1, U2,
    A V1, V2
    A Z1Az2 stb

  • @HealthyFoodFactory1
    @HealthyFoodFactory1 3 роки тому

    عالی👌👌👌

  • @dodznb238
    @dodznb238 2 роки тому

    Hellk my dear friend, very nice & good tutorial very infotmative i like big fully watched from philippines, bacolod city..👇🏿👇🏿👇🏿👇🏿👍🤝🙏🏼👏

    • @virasanaat8269
      @virasanaat8269  2 роки тому

      Hello my dear friend. 😘
      Thanks for watching

  • @partapsingh6855
    @partapsingh6855 2 роки тому

    With U1 and V1 connection wiring which direction the motor will run -----Clockwise or Anticlockwise

    • @virasanaat8269
      @virasanaat8269  2 роки тому +2

      hi sir. connect v1 to u1 and u2 to v1 for forward direction

  • @MdRana-ev8so
    @MdRana-ev8so 2 роки тому +1

    Can you please tell me how can i check this motor good or bad by meter????

    • @SexyBigDancer
      @SexyBigDancer 2 роки тому

      continuidad entre sus bobinas y no cortocircuito entre los cables y la carcasa

  • @locomotoride5255
    @locomotoride5255 2 роки тому

    What if the motor has only z1 and z2 then u1 and u2 connection the L1 - u1 -z1. Then L2- U2 -z2 the theres a common line U1 again to u1

  • @Metal.master110
    @Metal.master110 2 роки тому

    How to you do the wiring for forward and reverse switch on this ?

    • @virasanaat8269
      @virasanaat8269  2 роки тому

      Hi my friend .
      Watch this video , I hope it is useful
      ua-cam.com/video/jKZy3ItlxXE/v-deo.html

  • @Pradeepbommena
    @Pradeepbommena Рік тому

    Tell me... 4 pole two starttar revars and forward conection

  • @cockedhat1
    @cockedhat1 2 роки тому +4

    The final diagram, which we were all waiting for is obscured by thumbnails. Otherwise good.

    • @radurobert1
      @radurobert1 2 роки тому

      BECAUSE HE'S AN EVIL NERD . He did this on purpose for others to burn their motors ....
      also the switch is not clear gas the video is not 100% logic
      it is more like he expect everyone to have some knowledge and very high level of schemes comprehension which is sad

    • @SexyBigDancer
      @SexyBigDancer 2 роки тому

      tiene que bajar el video y luego verificar. Las miniaturas son automáticas de youtube

  • @onlydesimurgi4381
    @onlydesimurgi4381 2 роки тому

    Single phase me dono cable phase aata hai kya problem hai.

  • @galey94
    @galey94 Рік тому

    Then end of the video use links to more videos so I can't see the whole picture.

  • @lulamilenyamazana7342
    @lulamilenyamazana7342 2 роки тому +1

    Presentation advice:
    At the end of your presentation, leave a blank space or just the channell logo to put thumbnails for other videos.
    Great work of teaching though. You earned my like and subscription 👏🏻👏🏻👏🏻

  • @yahudaja2982
    @yahudaja2982 2 роки тому

    Sir, is it making 3 phase motor?

    • @virasanaat8269
      @virasanaat8269  2 роки тому

      hi friend this diagram is used for reverse and forward in single phase motors.
      did you mean that?

    • @virasanaat8269
      @virasanaat8269  2 роки тому +1

      no it is.this diagram used for reverse and forward direction in single phase motor.

  • @joezie2609
    @joezie2609 6 місяців тому

    😂😂😂😂😂❤ love U😅

  • @stormtomlinson5431
    @stormtomlinson5431 Рік тому +2

    cant see final wiring,well done ,watch your own vid at least once and you will notice this nonsense

  • @Papaboskitv
    @Papaboskitv Рік тому

    Problem Yung wire iisa Ang kulay

  • @kaieteurcanada
    @kaieteurcanada Рік тому

    confusion...!!

  • @user-zd8zl3xn5k
    @user-zd8zl3xn5k 11 місяців тому

    What kind of Mickey Mouse b******* is that