Mitsubishi FR-E700 remote mode control and parameter set up Single phase VFD. ( E720s, E740 English)

Поділитися
Вставка
  • Опубліковано 21 сер 2024

КОМЕНТАРІ • 24

  • @icemanb5065
    @icemanb5065 3 роки тому +2

    Hello. This will definitely help me fix a laundry machine that isn't reversing .The inf here will make trouble shooting the location of the problem easier. Thanks for this invaluable guide.

  • @IGSElectronics
    @IGSElectronics  3 роки тому

    Hello Fellow colleagues. If you enjoy the video please click that like button and if you did not, dislike it and let us know in comments, what was, that made you not happy with the content, so I can learn from it and make better videos for you in the future. Have a great day everyone.

  • @runbou3485
    @runbou3485 Рік тому

    Thankអរគុណ

  • @ace7709
    @ace7709 2 роки тому

    Do you have a video explaining temperature control ie transmitter input? I need the drive to control fan speed to maintain a temperature

  • @torbjrnsolbergstrand1058
    @torbjrnsolbergstrand1058 9 місяців тому

    I want to set up a signal lamp when the hertz is set to 40. How do i do that?

  • @halerazor80
    @halerazor80 3 роки тому

    I may be wrong but isn't your jumper on sourcing and not sinking in the video? I have been trying to replace an old yaskawa inverter with a mitsubishi e720, it is a dresser motor for a grinder 208v 3A and 30Hz. We run this motor at 234Hz but even after setting the max on P18 to 234Hz the motor will only run at 120Hz or not at all if we have the min frequency set at 0. We are only using the STF terminal and of course reset and alarm. Any help would be nice

    • @IGSElectronics
      @IGSElectronics  3 роки тому

      Hi There, it looks confusing but it is on sink, otherwise i would not be able to run. What is your base frequency set up and for you to go above 120 you need to change P1 to what ever frequency you need. Default is 120Hz max. Don't forget to make sure that the base frequency P3 is the same as motors frequency.

  • @dingdong7265
    @dingdong7265 Рік тому

    I need to extend the readout screen. How do i do this?

  • @walterjames9957
    @walterjames9957 3 роки тому

    Is a E720 capable of being reversed remotely via external signal insput?

  • @ntuthukotrevor4626
    @ntuthukotrevor4626 2 роки тому

    Can I please have the drawing for wiring a 3 wire

  • @berkotropia
    @berkotropia Рік тому

    😔I'm so disappointed! I bought the second Mitsubishi inverter just because the remote buttons seemed to be not working on the first one. However, this one also the same!! I am definitely missing out something but no idea what! I need someone who give me a full parameter list together with the drawings how to connect the buttons.
    This is crazy! I used the same pendant for numerous inverters and there was no problem at all! Anyone knows any course where I can go and wire these VFDs together mentored by someone?

  • @dobler6893
    @dobler6893 2 роки тому

    Kable putih dibawah koneksi potensio untuk apa..in inventer

  • @ibnohassi1226
    @ibnohassi1226 Рік тому

    Pararmitar de formatage?

  • @raymondgacusan35
    @raymondgacusan35 2 роки тому

    sir how to set slow to high speed by parameter but not stop the motor

    • @IGSElectronics
      @IGSElectronics  2 роки тому

      Check out the video for multi frequency setup

  • @mocharlachaitanya7753
    @mocharlachaitanya7753 3 роки тому

    How to extend display

  • @suriyaarasan7514
    @suriyaarasan7514 Рік тому

    Which parameter to control the motor torque

  • @ParmarYashpal98
    @ParmarYashpal98 3 роки тому

    Hi

  • @berkotropia
    @berkotropia Рік тому

    Finally, managed to do the same as you but this Mitsubishi is a piece of crap to compare to other descent, user friendly and easy to wire VFDs such as Powerflex, Danfoss, Schneider, Omron and even the Chinese AT1. Japanese are always have their stupid logic....I hate all of their products!