Din Rail Terminals

Поділитися
Вставка
  • Опубліковано 29 сер 2024
  • A look at some din rail terminals which will be used in the phase converter project. These are for 2.5mm² wires, but this style of terminal can be obtained in many different sizes and styles.
    ► Support this channel:
    Patreon: / jwflame
    PayPal Donations: xo4.uk/?PPP
    ► Social Media:
    Twitter: / jwflame
    Facebook: / jwflame
    Instagram: / jwflame
    ► Contact info, sending stuff in: etc.:
    xo4.uk/?YTT
    ► Website - More on this video and many other subjects
    Website: www.flameport.com

КОМЕНТАРІ • 131

  • @andreb.8266
    @andreb.8266 4 роки тому +10

    We use this type of terminals 15 years ago, we swapped to Wago clamp terminal for speed and long lasting. A clamp terminal will keep the wire inside when you have vibration and a screw therminal need to be screw again to secure the connection once a years or less often depending on vibration. The clamp termnial save us so much time when wiring a new panel it's incredible.

  • @aaron74
    @aaron74 4 роки тому +37

    I love how the subject matter is serious and technical, yet he's wearing a Superman shirt. Ha ha ha

    • @dogwalker666
      @dogwalker666 4 роки тому +1

      I'm sitting watching him wearing the same jacket with a top gear tee shirt guess it's an electrician thing lol.

    • @AztecWarrior69
      @AztecWarrior69 2 роки тому

      Superman IS serious.

    • @Wranorn
      @Wranorn Місяць тому

      Looks like Superman Pajamas.

  • @tinytonymaloney7832
    @tinytonymaloney7832 4 роки тому +2

    I have to confess I have never seen brown, grey or black terminals and deffo not red. Usually a sort of olive fawn colour. I am surprised as are other followers of yours JW that you are not using end locks.
    I always use the bootlace ferrules on the control cables when I wire these things up, much neater and easier to fit wire into terminal. Have come across these terminals in days of old where strands of wire have been cut out to ensure too large a cable fits into terminal... lol.
    Good vid as usual JW, cheers

    • @kevvywevvywoo
      @kevvywevvywoo 4 роки тому

      I always use a crimp-end of one sort or another in din terminals. It's all too easy to insert bare wires badly so they screw up at the end or a stray strand causes a short. . In a huge panel that could mean days of fault-finding wasted.

  • @tomwills918
    @tomwills918 4 роки тому +3

    Cheers John, excited to see more progress on phase converter. Nick Bundy did a video not long ago using these to move an old consumer unit inside the house. It was previously in the meter box outside. That was the first time I'd come across them but it was a neat solution. However your comment about square millimetres / millimetres squared pricked my ears up...
    Hope lockdown is going ok in Bournemouth
    From neighbouring Southampton
    Cheers

  • @GrahamDIY
    @GrahamDIY 4 роки тому +4

    I used a DIN cabinet when I changed my consumer unit.
    I actually installed the DIN cabinet on a small piece of plywood next to the new CU and ore-wires the DIN rails to the MCBs on a bench. Much easier. Then ripped out the old CU, installed the plywood as one and terminated the house cables to the DIN rail connectors which were all labelled and ready.
    Looks nice and neat and the CU swap was much quicker - it needed to be for my situation. It was my house.

  • @lethal0r
    @lethal0r 4 роки тому +4

    You and big clive are bloody awesome, I would buy you both many ales if I ever met you

  • @phildxyz
    @phildxyz 4 роки тому +23

    You can usually get dummy end caps which screw onto the DIN rail and stop the blocks moving sideways...

    • @AztecWarrior69
      @AztecWarrior69 2 роки тому +5

      They are called stop blocks. Not "dummy end caps".

  • @QUickstar77
    @QUickstar77 Рік тому

    Thank you so much for this video. I was looking at using a DIN rail to distribute power for a project for a networking closet, but I couldn't quite understand how to use them from the pictures and this video really helped me fill in the holes in my understanding.

  • @dogwalker666
    @dogwalker666 4 роки тому +9

    I have used thousands of these all makes all sizes alough the big ones 70mm plus tend to snop off.
    There is one point I have spent a lot of time in panels when they have been installed upside down when the springs age and work loose if on the rail the wrong way round any vibration causes then to fall off with obvious consequences this is even more of a problem with G rail which will lock the correct way but fall straight off if inverted.
    If you look at the bottom of those terminals you will se they are known as universal ie they will fit both top hat or G rail (asymmetrical) rail. If ordering make sure which type of rail they are for.

  • @andy530i
    @andy530i 4 роки тому +6

    Where I worked on panel wiring the different colours required an end cap on each one/row, especially importannt when using jumper bars.

  • @paullill5604
    @paullill5604 4 роки тому +4

    The end cover should be locked off with a locking stop end which screws to the rail, a terminal cover is also available which is usually used in industry.

  • @PaulSteMarie
    @PaulSteMarie 4 роки тому

    I like those shorting strips. The ones I have clip into place and can't skip over one: you clip them together two at a time.

  • @paulcostello7200
    @paulcostello7200 4 роки тому +4

    Cheers John, hope your keeping safe and Healthy

  • @AE-mu1jc
    @AE-mu1jc 4 роки тому +4

    1:20 UK leave the EU but they use our german DIN (Deutsche Institut für Normung) Schiene (rail) in so many boxes. That's funny.
    BTW: The small connectors with 1/2 DU (5.1 mm) are cheaper copies of the Weidmüller connectors. Orginal have 400V / 24A / 2,5 qmm.

  • @AE-mu1jc
    @AE-mu1jc 4 роки тому +4

    3:36 Outside the UK, in the good old Germany and some other EU-countries the once metal is only the DIN Stange (DIN rail). Around is only a plastic box.
    Only outside for "heavy duty" we use metal boxes for mechanical savety.

    • @mikeZL3XD7029
      @mikeZL3XD7029 4 роки тому

      What??

    • @tookitogo
      @tookitogo 8 місяців тому

      @@mikeZL3XD7029ok, as a native English speaker who speaks German fluently, I’ve become adept at decoding a lot of broken English written by speakers of German (and related languages, like Dutch). What they’re trying to say is “Outside the UK, e.g. in Germany and other EU countries, the only metal is the DIN rail. Everything else is plastic.”
      To the OP:
      “einzige” = only.
      “Nur/einmal” = once.

  • @Cornz38
    @Cornz38 3 роки тому

    Brilliant vid. The situation you state about moving a consumer unit is exactly what i am having to do and these are a great solution. Subbed.

  • @timballam3675
    @timballam3675 4 роки тому +3

    Use these all the time, I find it useful to install endstops that are attached like the earth connection as using a screwdriver on the screws tends to separate them.

    • @StreuB1
      @StreuB1 4 роки тому +2

      Yep, especially when you crank down on the screw on the earthing terminals to get a good bite on the rail, they really open up. That's why its always nice to like you said, put an endstop. Preferably an endstop with an embedded metal strip in the clip so it bites the rail as well and stops it from sliding down over time. Allen Bradley as well as Electec (ABB) are the end-stops I like as they have this embedded metal strip in the clip. The A/B ones are kinda sharp and they REALLY bite into the rail. They don't slide at all and if you try, they dig into the zinc coating on the rail and get even more secure.

  • @user-fr3fo3oh7s
    @user-fr3fo3oh7s 2 місяці тому

    Thank you very much sir in your tuitorial now i know to use the terminal block... ❤

  • @michaelcostello6991
    @michaelcostello6991 Рік тому

    Great video and the suggestion of using them to extend wires in domestic consumer unit.

  • @albertkleyn111
    @albertkleyn111 4 роки тому

    John, Thank You. Heard about these but never saw them. Very useful video, as always. Makes me glad to be a Patron !

  • @tuckkeongho
    @tuckkeongho 4 роки тому +7

    Personally, I hate the screw-type terminal blocks. Wires can become lose, and it take time to wire it up. I prefer the spring-lock type. Cost a bit more thought, esp for a home-use project.

    • @mikeZL3XD7029
      @mikeZL3XD7029 4 роки тому

      So you can't use a screwdriver and basic tools?
      Shame on you, spring type terminations are known to start fires when poorly done.
      But I guess that is what you get with DIY wiring.
      Keeps us Fire-fighters busy.

    • @brewertonpaul
      @brewertonpaul 4 роки тому

      For CoMPEX, ALL Din terminals MUST be tight, even empty ones.
      If any are loose, it is classed as a defect.
      Its a tedious job going round checking every single one so maintenance free spring loaded type are a god send

    • @epoxy1710
      @epoxy1710 Рік тому

      In my restored 1977 Trans am I used Weidmuller screw in terminal blocks to connect every wires in the car, nothing has loosed after 7 years. I even used two terminal blocks that I zip tied together in a hurry to connect each of the headlights. Never loosen even with a V8 under the hood.

    • @tookitogo
      @tookitogo 8 місяців тому

      @@mikeZL3XD7029Good quality spring terminals like WAGO and Phoenix Contact are extremely reliable.

  • @Comedean
    @Comedean 4 роки тому +8

    These terminals look like a copy of a very early design of the Weidmüller WDU2.5 terminal. The WDU2.5 is probably the most used DIN-Rail-Terminal in Austria and Germany.
    Does the marking-system from Weidmüller fit on these CONTA-CLIP terminals?

  • @SoYFooD2
    @SoYFooD2 4 роки тому +2

    not to long ago u use to use about 250.000 to 500.000 terminals like these a year.
    and i have scrude more than 2 million in my life time.
    its fun to see the looks on the interns face when he has to unpack u meter tall euro pallet and u tell in 3 months u need to do it again.

  • @Rich10000
    @Rich10000 4 роки тому

    I like the idea of using those to move a single phase board actually

  • @robertbrowne4049
    @robertbrowne4049 4 роки тому +1

    Thanks a million for your videos.

  • @kevvywevvywoo
    @kevvywevvywoo 4 роки тому

    The best dinrail terminals are siemens. They have plastic both sides, are fully symmetrical, and dont try to twist apart like the others. I've used cheaper ones in the past like Connectwell or Europa, and although they're ok for the money, I've had a few with stripped threads from new. Some of the most over-rated ones are Weidmuller/Klippon IMHO

  • @ChrisTheSparky
    @ChrisTheSparky 4 роки тому +11

    I put the earth at the end closing off the exposed end.

    • @StreuB1
      @StreuB1 4 роки тому +9

      The exposed end should always get a blocking card. Terminal block systems are not designed for the earthing block to provide covering for a live adjacent open terminal block. The covers snap in place so if the terminals work themselves apart and form a gap, the card moves with the terminal block and the contacts are always covered and protected. Also as well, earthing blocks should never be used as endstops. It should go earthing block, end-stop, blocking card, terminal block, terminal block,.....,end-stop.

  • @HamedAdefuwa
    @HamedAdefuwa 2 роки тому

    doing my first diy din rail and this video was super helpful, thank you

  • @RaithUK
    @RaithUK 4 роки тому

    Useful, I have never seen them before. Interesting video.

  • @paolo6336
    @paolo6336 4 роки тому +1

    John you need a cape. Hero's wear capes. Ergo.... *Orders Cape*

  • @exogator
    @exogator 4 роки тому

    I have the older style , rather than screws they use spring lock clips and to join multiple together you have a pin that drops between two. The grounds have a metal bar that rests on the rail rather than the locking screw that these ones use. I think I might get some of these new ones, they look more user friendly. Also have some fuse holder ones also.

    • @tookitogo
      @tookitogo 8 місяців тому

      The screw terminals _are_ the older style.

    • @exogator
      @exogator 8 місяців тому

      @tookitogo I only said that because they came out of a 15-20 year old hospital panel

  • @martinwinfield2935
    @martinwinfield2935 4 роки тому +1

    Thanks very informative and helpful.

  • @jontownsend8090
    @jontownsend8090 4 роки тому

    Thanks for the info, i was looking at relocating a consumer unit to a more accessible location, this would be more fit for purpose as to extend cables in a tidy manner. A wago style arrangement would suit me best as i am trying to move away from screw terminals as much as possible.

    • @BMW-Tourer
      @BMW-Tourer 2 роки тому

      Where did you buy them?

  • @petrutarabuta5617
    @petrutarabuta5617 2 роки тому

    Thanks!

  • @DjResR
    @DjResR 4 роки тому +13

    These Conta-Click ones look like Weidmüller clones._

    • @wesleypotter7969
      @wesleypotter7969 4 роки тому +3

      Link bar looks like it was copied from the older weidmuller sak range.

    • @AE-mu1jc
      @AE-mu1jc 4 роки тому +1

      Yes of course. AFAIK was Weidmüller the first company how start with this small 1/2 DU connectors.
      For low power them are smaller, AFAIK 1/3 DU. For high power thicker, 1 DU.
      They can't patent the function so many other companies make own style copies.
      If do you order direct at Weidmüller do you can buy every RAL colour.

    • @haywardsteve
      @haywardsteve 4 роки тому

      They look like the Klippon brand as well

    • @mikeZL3XD7029
      @mikeZL3XD7029 4 роки тому +1

      @@AE-mu1jc I believe Wiedmuller have the patent on this type of connector, yet the Chinese don't recognise any patents, so they are made as cheap as and probably don't fit the original specification for manufacture.

  • @mikeZL3XD7029
    @mikeZL3XD7029 4 роки тому

    @ John Ward,
    There are biege coloured end caps/retainers for Top Hat DIN Rail parts, they only have a central screw, that holds it to the DIN Rail.
    The worst thing you can ever strike is that useless G-profile DIN Rail, that was a thing in the 1980's.
    It was used in factories and try as you might to remove the terminals from the rail (with the supply still live) without snapping the bottom plastic clamp off, rendering it useless.
    Top Hat is the way to go.

  • @jonathanwebb9862
    @jonathanwebb9862 2 роки тому

    Thanks for this. Nice & clear.

  • @Xclub40X
    @Xclub40X 4 роки тому +2

    DIN rail terminals . . . A lot busier and more functional than most other rail terminals are at the moment.
    And no DIN does not mean Doncaster International

    • @JasperJanssen
      @JasperJanssen 4 роки тому +1

      Is t that where top gear is filmed?

  • @chaser1338
    @chaser1338 4 роки тому +1

    Can you cover generators please and how they work in great detail thanks👍

  • @AndyK.1
    @AndyK.1 4 роки тому +3

    If you used that to extend CU wiring and it joined all the earths together (via the din rail). Wouldn’t that cause a problem during testing ?

    • @jwflame
      @jwflame  4 роки тому

      Yes, for that application it would be better to use the insulated terminals for the CPC.

  • @ShadowzGSD
    @ShadowzGSD 4 роки тому +4

    KAK? was the DIN rail manufacturer really thinking about that name. 😱😁

    • @Marcel_Germann
      @Marcel_Germann 4 роки тому +1

      Of course he did, "C" and "E" are missing...

    • @DjResR
      @DjResR 4 роки тому +3

      Better than bearing manufacture named F.A.G. or terminal block named G.E.I._

    • @raychambers3646
      @raychambers3646 4 роки тому +1

      There used to a crane manufacturers called fairy.

    • @raychambers3646
      @raychambers3646 4 роки тому +1

      @Jannie Kirsten there used to be a firm called spruce spring clean.

    • @jaycee1980
      @jaycee1980 4 роки тому

      it's like the domestic appliances called SMEG, or SICK who make switches... there's even a company called f.a.r.t who make neon sign transformers :)

  • @gangguscrew_blanche
    @gangguscrew_blanche 3 роки тому

    Thank you for sharing

  • @snagright1300
    @snagright1300 4 роки тому

    Another good video john thank mate

  • @ashleybaker2221
    @ashleybaker2221 4 роки тому +2

    H jd what the best way to convert my generator from 3-phase to single phase .I seen converter from single to 3 phase but not to opersit way round eny advice thanks

    • @jwflame
      @jwflame  4 роки тому +4

      There is no conversion, single phase loads can be connected between neutral and one of the phases.

  • @blankblank4459
    @blankblank4459 4 роки тому +3

    John, if used as described to extend cables for a cu change, would you use the green earth terminals for CPCs? All of the CPCs in the install would them be common at the din rail. Could this affect your readings during inspection and test? Maybe lower R2.

    • @jwflame
      @jwflame  4 роки тому +2

      Better to use the insulated terminals for that, otherwise all the CPCs would be connected together, making any testing at the CU meaningless.

    • @blankblank4459
      @blankblank4459 4 роки тому

      @@jwflame Thanks John. It is obvious thinking about it now that it would completely mess up the ring final figure 8 test results at least.

  •  4 роки тому +2

    Linking them together to join more wires isn't there a danger you will exceed the 25amps rating?

    • @Marcel_Germann
      @Marcel_Germann 4 роки тому +4

      Nope. The whole circuit is fused with 25A at maximum. In case of 2.5mm² wiring I would rather recommend fusing it with 20A. You'll have to ensure that the incoming wire is fused properly. It doesn't matter how many wires there are, they can all not draw more than 25A if the whole circuit is fused with 25A. The overcurrent protection will prevent this.

    • @Gameboygenius
      @Gameboygenius 4 роки тому +3

      They would be typically be used in an industrial setting, so everything connected has a known rated current and will likely be fused. So not a problem assuming it's designed correctly.

    • @timearp8185
      @timearp8185 4 роки тому +1

      This is where you would need to design the installation and then specify the components needed, CEF have many different amp rated components: www.cef.co.uk/catalogue/categories/din-rails-and-terminals-din-rail-terminals

    • @Marcel_Germann
      @Marcel_Germann 4 роки тому +1

      If you create a circuit you'll have to design it that way that the fuse/MCB rating depends on the weakest link of the chain. Let's say I design a german outlet circuit. Wiring is 2.5mm², under best circumstances it's rated for 25A, normally 20A. Connectors in junction boxes, let's say Wago 221, are rated for 32A. The outlets are rated for 16A, so the circuit is fused with 16A at max (circuit breaker B16A). No matter how many outlets are connected to this circuit. In rooms like living rooms or bedrooms one 16A circuit covers all outlets (and could supply the lighting too without any kind of trouble), and that's sufficient because there are normally no appliances with a high demand. In the kitchen you require several circuits, mostly dedicated circuits with only one outlet for one specific appliance like a refridgerator or a dish washer. The thing is not about demand, you can also hook up the dish washer and the refridgerator on the same circuit, but if you require to switch-off one circuit for whatever reason the other appliance would also have no electric power.

    •  4 роки тому

      @@Gameboygenius What do they say about assume you make an ass out of you and me.

  • @silverstone7778
    @silverstone7778 3 роки тому

    Love how much knowledge you give out. If you were to choose between push-in connection and screw connection terminal blocks, which one would you choose and why? I keep hearing that screw connections are unreliable due to vibration, while push-in connection risks of getting loose due to thermal cycling. Specifically I'm looking at Phoenix PTI 2.5 PE L N vs Phoenix UTI 2.5 PE L N. Thanks

    • @Learn_123
      @Learn_123 Рік тому

      U can go for elmex Control

  • @tarassu
    @tarassu 4 роки тому

    We all love flathead screwdrivers, do we...

  • @mostafafalah4361
    @mostafafalah4361 4 роки тому

    Sir
    Thank you so much for everything you have done
    I watched all of your videos
    Please do you have catalogue or company you recommend for us for the terminal blocks
    I need to add it to inventory

  • @bostedtap8399
    @bostedtap8399 4 роки тому +2

    👍

  • @Martin120577
    @Martin120577 4 роки тому

    The PE terminal with conducting connections are allowed in insulation class I panels, but when inspecting Insulation class II panels we also come across them alot.. this is not allowed. Its a common made mistake.
    In these kind of panels a continuity check with 200mA , proofs such a mistake easily.

  • @frankowalker4662
    @frankowalker4662 4 роки тому

    Nifty connectors.

  • @MatSmithLondon
    @MatSmithLondon 3 роки тому

    What's a go-to place to buy these online (UK)? RS Components?

  • @mahdavimail
    @mahdavimail 4 роки тому

    Tnx for video. What’s the screwdriver slotted size for these terminals?

    • @mikeZL3XD7029
      @mikeZL3XD7029 11 місяців тому

      Usually 3.5-4.0mm off the top of my head.

  • @markrowland5393
    @markrowland5393 4 роки тому

    Good video. Where's the best place to get small quantities of these connectors?

    • @jwflame
      @jwflame  4 роки тому +1

      Most electrical suppliers such as CEF, Rexel, also suppliers such as Farnell, RS.

    • @markrowland5393
      @markrowland5393 4 роки тому

      Thanks John.

  • @AztecWarrior69
    @AztecWarrior69 2 роки тому

    You are technically putting them upside down.

  • @NiKo-ig2td
    @NiKo-ig2td 4 роки тому

    Using it to extend the wiring for consumer unit is questionable as they are rated 24A and the socket circuit is 32A or 40A

    • @jwflame
      @jwflame  4 роки тому +3

      Other ratings are available.

  • @fomblin
    @fomblin 4 роки тому

    Sad Space Invaders (2:10)

  • @brewertonpaul
    @brewertonpaul 4 роки тому

    @4:40 those joining strips are not very good as it can remove IP2X protection. There are other push in "blade" type joiners that are much better.

    • @AztecWarrior69
      @AztecWarrior69 8 місяців тому

      "There are other push in "blade" type joiners that are much better." Better? No. They can fall out and lose connection if not properly inserted. The screw type are way more secure. As to protection the make cover strips for that.

    • @tookitogo
      @tookitogo 8 місяців тому

      You have to use the jumper type specific to the terminal blocks in use. The ones he showed are designed for screw jumpers, so you must use the screw jumpers made for that series. Others are designed for the blade-type jumpers, and in those you must use blade-type jumpers _specific to that series._

    • @AztecWarrior69
      @AztecWarrior69 8 місяців тому

      @@tookitogo Timestamp?

  • @Learn_123
    @Learn_123 Рік тому

    Can I get 3d model of this part ?

    • @tookitogo
      @tookitogo 8 місяців тому

      The big manufacturers have the models on their websites, as well as complete (free) web-based layout programs that let you place modules on the rail, jumper them, etc.

  • @robertgaines-tulsa
    @robertgaines-tulsa 4 роки тому +1

    It sounds like the audio is being heavily compressed as in volume leveling.

    • @jwflame
      @jwflame  4 роки тому +2

      Nothing has changed in the way the original is created, presumably some UA-cam encoding issue.

    • @richardcrook3427
      @richardcrook3427 4 роки тому +4

      @@jwflame I thought the audio was fine. Much better than most channels. Good work John.

  • @Tangobaldy
    @Tangobaldy 4 роки тому +1

    Chocky blocks, electrical tape or selotape. So much easier

  • @brotheradam
    @brotheradam 4 роки тому

    hmm... but what i really need is some cross cheat sheet for UK wire types compared to Canadian wire types compared to USA wire types..lol...
    having to guess between 12 guage and 2.5mm and 14 guage, thhn..thwn... bs specs..lol..
    Life in Caribbean hard.. only constant is the conduit is all marked 20 or 25mm from trinidad..lol bs standards..

  • @wolveswonderers3580
    @wolveswonderers3580 4 роки тому +1

    Do you have an email address john

  • @cirebyte7588
    @cirebyte7588 4 роки тому

    1:15 ?

  • @junxiachiku
    @junxiachiku 8 днів тому

    g

  • @muh1h1
    @muh1h1 4 роки тому

    Anyone else slightly annoyed about how he consistently clicks them in from the wrong side?

    • @PigTailLeo
      @PigTailLeo 4 роки тому

      I'm searching all over to understand how to remove those block terminals. Eventually this video kind of demonstrates that but makes me more confused about the direction to click in. @muh1h, your comment clarifies my doubt. (I still appreciate John's explanation here though.)

  • @RWATraineeElectrician
    @RWATraineeElectrician 4 роки тому

    I bet they're 3D printed.

  • @mohancena6166
    @mohancena6166 Рік тому

    Jai BJP

  • @user-fc1qd8fw5h
    @user-fc1qd8fw5h 4 роки тому

    👍