Connect to MicroLogix with Serial

Поділитися
Вставка
  • Опубліковано 11 вер 2024
  • In this video I show the cable and the required software to connect to a MicroLogix 1100, 1400, or 1500. The Cable is a 1761-CBL-PM02, the Serial to USB converter is a 9300-USBS. You will need RSLinx Classic Lite (or better) and RSLogix 500 which is a licensed software.
    At 6:25 I switch the serial cable from the MicroLogix1500 to the MicroLogix1100, that is why Linx lost connection and regained it to a different PLC and I repeated the upload and save procedure.
    Hope this helps, let me know in the comments if there is something I can make a video of for you.

КОМЕНТАРІ • 14

  • @AlloyedFrequencies
    @AlloyedFrequencies 20 днів тому +1

    Thank you so much. The step I missed was auto configure.

  • @Rauf1980TR
    @Rauf1980TR 4 місяці тому

    Hi, i want to check PLC running software version via pot switch. Could you please explain is it safe to do it? Because with this pot switches, i can change also configuration.Could you please advise? Thanks.

    • @shortplcvideos5764
      @shortplcvideos5764  4 місяці тому

      Rauf, what model PLC are you requesting this for? Thank you for the question.

  • @ahmedaljuboori6884
    @ahmedaljuboori6884 2 роки тому

    Hi
    How can I contact you ?

  • @eudismendoza1153
    @eudismendoza1153 Рік тому

    Hello, what cable can you use to connect to Micrologix 1200 PLC?

    • @shortplcvideos5764
      @shortplcvideos5764  Рік тому

      Communication Cables Use only the following communication cables with the MicroLogix 1200
      controllers.
      • 1761-CBL-PM02 series C or later
      • 1761-CBL-HM02 series C or later
      • 1761-CBL-AM00 series C or later
      • 1761-CBL-AP00 series C or later
      • 1761-CBL-PH02 Series A or later
      • 1761-CBL-AH02 Series A or later
      • 2707-NC8 series A or later
      • 2702-NC9 series B or later
      • 2707-NC10 series B or later
      • 2707-NC11 series B or later
      Page 1-4 of this document literature.rockwellautomation.com/idc/groups/literature/documents/um/1762-um001_-en-p.pdf

  • @luisavelar9883
    @luisavelar9883 2 місяці тому +1

    Hey could you help me out?

    • @shortplcvideos5764
      @shortplcvideos5764  2 місяці тому

      I'm not sure, what is your question?

    • @luisavelar9883
      @luisavelar9883 2 місяці тому

      @@shortplcvideos5764 if we are changing a plc with extension cards that are 120 AC to a PLC that is 24VDC, how could I use interposing relays to make everything function as it currently sits?

    • @luisavelar9883
      @luisavelar9883 2 місяці тому

      @@shortplcvideos5764did my comment send ?

  • @ahmedaljuboori6884
    @ahmedaljuboori6884 2 роки тому

    Hi
    How can I contact you?

    • @shortplcvideos5764
      @shortplcvideos5764  2 роки тому

      Just here in the comments is fine. What's up?

    • @ahmedaljuboori6884
      @ahmedaljuboori6884 2 роки тому

      I have a plc MicroLogix"1500
      Processor Unit
      SE
      CAT
      1764 - LRP needs updating

    • @shortplcvideos5764
      @shortplcvideos5764  2 роки тому

      @@ahmedaljuboori6884 If you need to connect to that PLC, you will need this cable: 1761-CBL-AP00
      I may be able to get you a pinout of this cable if you want to try to build your own.